HomeMy WebLinkAboutA036 - Hearing on rezoning prop at 259 Hyland Ave from Residential High Density (RH) with W. Univ (O-UIW) to Residential High Density (RH) with W. University Pedestrian Enhancement District Overlay(O-Wuped)ITEM #:36
DATE:09-22-26
DEPT:P&H
SUBJECT:HEARING ON REZONING PROPERTY AT 259 AND 263 HYLAND AVENUE
FROM RESIDENTIAL HIGH DENSITY (RH) WITH WEST UNIVERSITY
IMPACTED DISTRICT OVERLAY (O-UIW) TO RESIDENTIAL HIGH DENSITY
(RH) WITH WEST UNIVERSITY PEDESTRIAN ENHANCEMENT DISTRICT
OVERLAY (O-WUPED) WITH A MAJOR SITE DEVELOPMENT PLAN
COUNCIL ACTION FORM
BACKGROUND:
259 Hyland Avenue is owned by Dayton Park, LLC and 263 Hyland Avenue is owned by
Adventure Investments, LLC, both represented by Chuck Winkleblack. The applicant proposes
to rezone and redevelop the two existing lots (See the Location Map). Both properties are
currently zoned Residential High-Density Zone “RH” with the West University Impact Overlay.
The 259 Hyland site contains a duplex and 263 Hyland contains an apartment building. Both
buildings would be demolished to accommodate future development.
The proposed project will maintain the base RH zoning, but will amend the applicable overlay
from West University Impact (O-IUW) to the new “O-WUPED” (West University Pedestrian
Enhancement District). The O-WUPED was recently created to implement Ames Plan 2040
policies supporting walkable urban infill within the Residential Neighborhood Walkable Urban
(RN-4) land use designation. RN-4 encourages higher density housing, walkability, and
redevelopment that creates a high-quality built environment and sense of place (see the
attached Plan 2040 Excerpt). The O-WUPED is to be applied on a case-by-case basis to
property along Hyland and Sheldon Avenues.
The benefit of the proposed Overlay Zoning compared to existing zoning, are an
increase in allowable density and reduced parking when new buildings are designed to
the standards of the Overlay District. The Overlay includes standards and design principles
to guide the design of a site to support both compatibility with the existing multi-family
character of the area and to encourage intensification with high interest urban design elements
and material quality.
In order to approve a rezoning request to O-WUPED, an application must include concurrent
review of a Major Site Development Plan (MSDP) to determine if a proposed project design is
consistent with the O-WUPED and achieves the purpose of the District. The Addendum
includes the purpose and establishment requirements for the rezoning.
MAJOR SITE DEVELOPMENT PLAN:
The proposed project is the first project to be reviewed with the new O-WUPED zoning. The
applicant was the impetus for initial request for the creation of the O-WUPED zoning with a
vision to redevelop two sites into one new development. The project has evolved substantially
since the original concept was presented in the spring of 2025 to the project proposed today.
1
Initially the site was to be redeveloped in one phase with one building oriented to Hyland. The
applicant later determined that due to site conditions and timing a two building and two-phase
project would be more feasible, which is the current proposal.
The proposed development will be built as two independent sites. There will be no sharing of
parking, access, setbacks, etc. A concurrent boundary line adjustment accompanies the
project to establish property lines that match the proposed project sites. The applicant plans to
proceed this fall with the 259 Hyland site and then proceed with the 263 Hyland site next
summer. Each site is evaluated for consistency with the O-WUPED. Each site includes
requested design relief for alternative design features and application of design
principles, which act as design guidelines.
The applicant has included a narrative that accompanies the MSDP to articulate their
approach to the project design and consistency with the standards and design principles. The
O-WUPED standards are mandatory elements of compliance while the design principles are
written as design guidelines to help shape the features of the project that will conform to the
purpose of the O-WUPED. Essentially, if a project achieves the Design Principles it should be
in conformance with the O-WUPED purpose. Some design latitude is permitted through
various alternative design tools of the Zoning Ordinance for landscaping and 20% setbacks
reductions along with the application of the design principles to the project. The applicant
refined the plans for the past few months culminating in this application.
Staff worked with the applicant’s design team to address the Design Standards and Principles
for the project as it evolved and became more consistent with the O-WUPED. The Overlay
identifies a preference for traditional residential design, but also allows for contemporary
design with flat roofs as is proposed.
Staff provided feedback regarding three challenging issues for the design and the site
related to 1) Building A’s front setback along, 2) Building B’s approach to Hyland
architectural relief, 3) Building B's design emphasis regarding the primary entrance
facing Oakland. These are the primary points of discussion with the proposed Major
Site Development Plan that accompanies the rezoning request.
259 Hyland-Building A
The property located at 259 Hyland Ave is approximately 0.27 acres. The building is 3-stories
or approximately 37 feet tall. (see the attached Elevations for Building A details). The owner
proposes 13 units for the building, 7 being one-bedroom units and 6 being two-bedroom units.
The O-WUPED permits a density of 83 bedrooms per acre. Based on the proposal, 19
bedrooms are proposed, which is below the maximum bedroom density of 22.41 for the site.
The complete O-WUPED ordinance with its purpose requirements, standards, and design
principles is included as an attachment for reference. A table summarizing major standards
and requested design features is included in the Addendum. The design relief for the building
includes accepting a 20% reduction of the front yard setback to 20 feet, although originally
requested as a front yard setback of 15 feet, a walkway to the street at 4-feet rather than 5
feet, and design principles approval of the entry overhangs and projecting window boxes with
a variable roof parapet to provide relief for buildings that are 3-stories in height or greater.
2
Because of the front setback issues for Building A, the applicant is in the process of
seeking a variance to the rear setback to allow for the building to conform to the 20-foot
front yard setback. Staff supports the applicant's variance request to the ZBA to
reduce the rear setback. As shown in the plans that are attached, Building A has a 15-
foot front setback. If the variance is approved the building will move to the west by five
feet, but the fundamental design will not change. If the variance is not approved, the
applicant will need to return to Council to discuss options on how to proceed. The
variance application is a product of staff discussion with the applicant and the project's
review at the P&Z meeting.
263 Hyland Avenue – Building B
The property located at 263 Hyland Avenue is 0.47 acres. The building is intended to develop
during Phase 2 following the construction of Building A. The building is 4-stories or
approximately 45 feet tall when calculating the average grade of the site (see the attached
Elevations for Building B details). The owner proposes 19 units for the building, 10 being one-
bedroom units and 9 being two-bedroom units. The building meets the density maximum for
bedrooms in the O-WUPED, proposing 28 bedrooms and having a maximum allowance of 39
bedrooms for the site. Parking for this building is partially enclosed and partially uncovered
along the west property line. Access is from Oakland.
A table summarizing major standards and requested design features is included in the
Addendum.
The design relief for the building includes consideration of a 20% alternative design relief to
allow a maximum setback of 26.5 feet instead of 25 feet for a building corner along Oakland, a
reduction of the front setback from 25 feet to 20 feet along Hyland, agreement that 8-inch
window box projections and variable parapet height meet design standards for building relief,
and that the Oakland entrance achieves the entrance design principles for corners and
connection to Hyland.
Building B is substantially larger than Building A, but replicates the design features of
Building A. Staff identified concerns with meeting building relief guidelines of a 30"
depth of relief for a front facade and the Oakland corner entrance guidelines at the time
of the P&Z Commission meeting. At the P&Z meeting the Commission reviewed the
options for adding relief and ultimately supported the building as proposed. However,
the Commission voted to accept staff's recommendation for enhancing the Oakland
entrance to add more emphasis and connect architecturally to the corner at Hyland.
Staff has included this recommendation as a condition of approval.
PLANNING AND ZONING COMMISSION:
Notice was provided by publication, mail to property owners within 400 feet, and a notice sign
placed on the site. No comments were received. The Commission reviewed the project and
addressed the O-WPUED Design Principles and standards focused on the front yard setback
of Building A as discussed above and architectural treatments of Building B.
The Commission agreed with the applicant that the site is blighted and redevelopment will be
beneficial. The discussion focused on the requirements of the zoning and if the project had
fully achieved the intent. Ultimately the Commission voted to add two conditions of
approval to the proposal with a 3-2 vote. The first condition was to seek a variance to
3
the rear yard for Building A in order to meet the code standard of a 20 foot setback, this
is underway by the applicant. The Commission also included a condition to address
the corner stair tower and Oakland entrance of Building B, believing it has not achieved
the intent of emphasizing the entrance and connection to Hyland. This condition also
is recommended by staff as part of the approval.
ALTERNATIVES:
1. City Council can approve on first reading the request for rezoning of both 259 and 263
Hyland Avenue from “RH” Residential High-Density Zone and “O-UIW” West University
Impacted District to “RH” and “O-WUPED” West University Pedestrian Enhancement
District and a resolution for approval of the the proposed Major Site Development with
the following conditions:
a. Provide an outdoor Lighting plan prior to issuance of a building permit.
b. Provide a roof plan with mechanical equipment screening prior to issuance of a
building permit.
c. Provide material sample/references for clay brick specifications prior to issuance of
a building permit.
d. Provided an updated site plan reflecting a Front Yard Setback of 20 Feet with
approval of a rear yard variance for 259 Hyland prior to issuance of a building
permit for 259 Hyland. (If the variance is not approved, the applicant will return to
City Council prior to third reading for approval of the project)
e. Require 263 Hyland Building B modifications to the architectural elements of the
primary front entrance at the corner to conform to Design Principle 7.a., which
would include more emphasis on the corner of the building and wrapping the
corner to the Oakland entrance to make it a more significant element of the design.
Alternatively, the canopy along Oakland could be extended in length to be more
substantial in scale to the building and include tie back rods to the brick or for it to
be expanded in size and area as a porch with columns to the ground instead of a
cantilevered canopy. Final Design approval will be by the Planning Director or
referred to City Council for approval, prior to issuance of a building permit for 263
Hyland.
2. The City Council may approve with modified conditions the rezoning and Major Site
Development Plan for either or both of 259 and 263 Hyland Avenue from “RH”
Residential High-Density Zone and “O-UIW” West University Impacted District to “RH”
and “O-WUPED” West University Pedestrian Enhancement District with a Major Site
Development Plan.
3. The City Council can deny the application as not achieving the standards of the
requested O-WUPED rezoning.
4
CITY MANAGER'S RECOMMENDED ACTION:
The proposed project is a substantial change to the Hyland Oakland area and will be a highly
visible redevelopment that implements the vision of Ames Plan 2040. The project is designed
around contemporary building styles with flat roofs and parapets formatted over ground floor
parking and is efficiently designed with smaller apartment units as intended with the Overlay
District in support of the lower parking requirements.
Staff is generally supportive of the overall design, but believes that some modifications
are needed for Building A and Building B to be fully consistent with the intent of the O-
WUPED. The purpose of the O-WUPED is to not only efficiently support redevelopment,
but to also achieve the goal of improvement in the architectural character of the area to
enhance the pedestrian environment as described within the RN-4 land use designation
of Ames Plan 2040. The recommended variance for Building A and the enhancements
to Building B's Oakland entrance help ensure consistency with the Overlay. Therefore,
it is the recommendation of the City Manager that the City Council adopt Alternative No. 1.
ATTACHMENT(S):
259 & 263 Hyland Rezoning.docx
Location Map.pdf
Zoning Map.jpg
Major Site Plan
Elevations
Floor Plans
Renderings.pdf
Addendum.docx
Applicant Rezoning Narrative.pdf
5
__________________________________________________________________________________________________________
DO NOT WRITE IN THE SPACE ABOVE THIS LINE, RESERVED FOR RECORDER
Prepared by: Renee Hall City Clerk’s Office, 515 Clark Avenue, Ames, IA 50010 Phone: 515-239-5105
Return to: Ames City Clerk, P.O. Box 811, Ames, IA 50010
ORDINANCE NO.
AN ORDINANCE AMENDING THE OFFICIAL ZONING MAP OF THE
CITY OF AMES, IOWA, AS PROVIDED FOR IN SECTION 29.301 OF THE
MUNICIPAL CODE OF THE CITY OF AMES, IOWA, BY CHANGING THE
BOUNDARIES OF THE DISTRICTS ESTABLISHED AND SHOWN ON
SAID MAP AS PROVIDED IN SECTION 29.1507 OF THE MUNICIPAL
CODE OF THE CITY OF AMES, IOWA; REPEALING ALL ORDINANCES
AND PARTS OF ORDINANCES IN CONFLICT HEREWITH AND
ESTABLISHING AN EFFECTIVE DATE
BE IT HEREBY ORDAINED by the City Council of the City of Ames, Iowa;
Section 1: The Official Zoning Map of the City of Ames, Iowa, as provided for in
Section 29.301 of the Municipal Code of the City of Ames, Iowa, is amended by changing
the boundaries of the districts established and shown on said Map in the manner
authorized by Section 29.1507 of the Municipal Code of the City of Ames, Iowa, as
follows: That the real estate, generally located at 259 and 263 Hyland Avenue is rezoned
from Residential High Density (RH) with West University Impacted District Overlay (O-
UIW) to Residential High Density (RH) with West University Pedestrian Enhancement
District Overlay (O-WUPED) with a Major Site Development Plan.
Real Estate Description: 259 and 263 Hyland Avenue, Story County Ames,
Iowa
Section 2: All other ordinances and parts of ordinances in conflict herewith are
hereby repealed to the extent of such conflict.
Section 3: This ordinance is in full force and effect from and after its adoption and
publication as provided by law.
ADOPTED THIS ________ day of _________________________, ______.
6
_____________________________ _______________________________
Renee Hall, City Clerk John A. Haila, Mayor
7
HYLAND AVE
OAKLAND ST
SHELDONAVE
CAMPUS AVE
SHELDON
AVE
EXT
Rezoning with Major Site Development Plan 259 & 263 Hyland AvenueAmes, IA
0 250 500125Feet¯Legend
Subject Area
TextTextText
8
9
T
OAKLAND ST
SHEL
D
O
N
A
V
E
CA
M
P
U
S
A
V
E
WOODLAND ST
WEST ST
PAMMEL DR
SH
E
L
D
O
N
A
V
E
UNION DR
HY
L
A
N
D
A
V
E
BI
S
S
E
L
L
R
D
SHEET
B
o
l
t
o
n
&
M
e
n
k
,
I
n
c
.
20
2
6
,
A
l
l
R
i
g
h
t
s
R
e
s
e
r
v
e
d
c H:
\
H
U
N
Z
I
\
2
4
X
1
3
5
5
0
5
0
0
0
\
C
A
D
\
C
3
D
\
1
3
5
5
0
5
G
1
0
1
.
d
w
g
8/
2
1
/
2
0
2
6
1
1
:
1
7
:
4
7
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HUNZIKER DEVELOPMENT
259/263 HYLAND
24X.135505.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100
Email: Ames@bolton-menk.com
www.bolton-menk.comR
G1.01
TITLE SHEET
NOTE: EXISTING UTILITY INFORMATION SHOWN ON THIS
PLAN HAS BEEN PROVIDED BY THE UTILITY OWNER. THE
CONTRACTOR SHALL FIELD VERIFY EXACT LOCATIONS PRIOR
TO COMMENCING CONSTRUCTION AS REQUIRED BY STATE
LAW. NOTIFY IOWA ONE CALL 1-800-292-8989 OR 811
THE SUBSURFACE UTILITY INFORMATION IN THIS PLAN IS
UTILITY QUALITY LEVEL D UNLESS OTHERWISE NOTED. THIS
UTILITY LEVEL WAS DETERMINED ACCORDING TO THE
GUIDELINES OF CI/ASCE 38-02, ENTITLED "STANDARD
GUIDELINES FOR THE COLLECTION AND DEPICTION OF
EXISTING SUBSURFACE UTILITY DATA."
FEETSCALE
0 800400
R
PLAN REVISIONS
REV ISSUED FOR DATE
ZONING
RESIDENTIAL - RH & O-WUPED
OWNER
HUNZIKER DEVELOPMENT
105. S 16TH ST.
AMES, IA 50010
PREPARED BY
BOLTON & MENK
1519 BALTIMORE DRIVE
AMES, IA 50010
R
NOTE: EXISTING UTILITY INFORMATION SHOWN ON THIS
PLAN HAS BEEN PROVIDED BY THE UTILITY OWNER. THE
CONTRACTOR SHALL FIELD VERIFY EXACT LOCATIONS PRIOR
TO COMMENCING CONSTRUCTION AS REQUIRED BY STATE
LAW. NOTIFY IOWA ONE CALL 1-800-292-8989 OR 811
THE SUBSURFACE UTILITY INFORMATION IN THIS PLAN IS
UTILITY QUALITY LEVEL D UNLESS OTHERWISE NOTED. THIS
UTILITY LEVEL WAS DETERMINED ACCORDING TO THE
GUIDELINES OF CI/ASCE 38-02, ENTITLED "STANDARD
GUIDELINES FOR THE COLLECTION AND DEPICTION OF
EXISTING SUBSURFACE UTILITY DATA."
THE 2025 EDITION OF THE "IOWA STATEWIDE URBAN
SPECIFICATIONS FOR PUBLIC IMPROVEMENTS" AND
THE CURRENT CITY OF AMES SUPPLEMENTAL SPECIFICATIONS.
MUTCD 2023 AS ADOPTED BY IOWA DEPARTMENT OF
TRANSPORTATION.
ALL APPLICABLE FEDERAL, STATE, AND LOCAL LAWS AND
ORDINANCES WILL BE COMPLIED WITHIN THE CONSTRUCTION
OF THIS PROJECT.
GOVERNING SPECIFICATIONS
PLAN REVISIONS
REV ISSUED FOR DATE
MY LICENSE RENEWAL DATE IS
PAGES OR SHEETS COVERED BY THIS SEAL:
LIC NO.DATE:
I OWA
LIC
ENSED PROFESS IONAL ENGINEER
I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS
PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION
AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER
UNDER THE LAWS OF THE STATE OF IOWA.
21974
DECEMBER 31, 2025
ALL SHEET
Gregory A.
Broussard,
21974
Gregory A. Broussard, P.E.PRELIMIN
A
R
Y
NOT FOR
C
O
N
S
T
R
U
C
T
I
O
N
,
RECORDI
N
G
P
U
R
P
O
S
E
S
,
O
R
IMPLEM
E
N
T
A
T
I
O
N
.
SITE PLANS FOR
AUGUST, 2026
MAP OF
STORY COUNTY
STORY COUNTY, IA
HUNZIKER DEVELOPMENT
259/263 HYLAND AVE
PROJECT LOCATION
STAGING
CONTRACTOR SHALL PROVIDE THE FOLLOWING TRAFFIC
CONTROL WHILE WORKING IN THE PUBLIC R.O.W.:
-WORK ON HYLAND AVE UTILITIES - TC228
SHEET LIST TABLE
SHEET NUMBER SHEET TITLE
G1.01 TITLE SHEET
G1.02 LEGEND
G2.01 GENERAL NOTES
G2.02 DETAILS
C1.01 - C1.02 EXISTING CONDITIONS & REMOVALS
C2.01 SITE GEOMETRICS
C3.01 EROSION CONTROL PLAN
C4.01 - C4.02 GRADING PLAN
C5.01 - C5.02 UTILITY PLAN
C6.01 - C6.02 SIDEWALK ADA
C7.01 - C7.02 LANDSCAPING PLAN & DETAILS
C8.01 PHASING PLAN
C9.01 TRAFFIC CONTROL PLAN
THIS PLAN SET HAS 18 SHEETS
20% ALTERNATIVE DESIGN ADJUSTMENT REQUESTS
BUILDING A (SOUTH)
-REAR YARD SETBACK ADJUSTMENT FROM 25' TO 20.53' (18%)
-FRONT ENTRANCE SIDEWALK WIDTH FROM 5' TO 4' (20%)
BUILDING B (NORTH)
-REAR YARD SETBACK ADJUSTMENT FROM 25' TO 20.53' (18%)
-MAXIMUM FRONT YARD SETBACK ON OAKLAND ADJUSTMENT
FROM 25' TO 26.03' (4%)
-FRONT YARD SETBACK ON HYLAND ADJUSTMENT
FROM 25' TO 20' (20%)
10
EXISTING TOPOGRAPHIC SYMBOLS
DRIVEWAY
HATCH PATTERNS
GRADING INFORMATION
952
950
952
950
1:4
HMA PAVEMENT
F F F F
E E E E
G G G G
XXXXXXXXXXXX
EXISTING PRIVATE UTILITY LINES
STORM SEWER RECTANGULAR CASTING
STORM SEWER CIRCULAR CASTING
STORM SEWER FLARED END / APRON
CURB BOX
FIRE HYDRANT
MANHOLE
WATER REDUCER
WATER BEND
PROPOSED TOPOGRAPHIC SYMBOLS
CLEANOUT
LIFT STATION
RIP RAP
OE OE OE OE
C C C C
DRAINAGE FLOW
BENCH
BUSH
CATCH BASIN CIRCULAR CASTING
CURB STOP
CATCH BASIN RECTANGULAR CASTING
SIGNAL CONTROL CABINET
CLEAN OUT
DRINKING FOUNTAIN
FLARED END / APRON
FLAG POLE
FUEL PUMP
GRILL
HANDICAP SPACE
HANDHOLE
FIRE HYDRANT
MAILBOX
MANHOLE-HEAT
MANHOLE-ELECTRIC
MANHOLE-GAS
MANHOLE-SANITARY SEWER
MANHOLE-STORM SEWER
MANHOLE-COMMUNICATION
MANHOLE-UTILITY
PEDESTRIAN PUSH BUTTON
PEDESTAL-ELECTRIC
PEDESTAL-COMMUNICATION
VALVE POST INDICATOR
PARKING METER
LIGHT POLE
POLE-UTILITY
POST
PICNIC TABLE
RAILROAD SIGNAL POLE
REGULATION STATION GAS
TREE-DECIDUOUS
SATELLITE DISH
SIGN TRAFFIC
WATER SPIGOT
IRRIGATION SPRINKLER HEAD
IRRIGATION VALVE BOX
TREE STUMP
TELEPHONE BOOTH
TRANSFORMER-ELECTRIC
TREE-DEAD
TRASH CAN
TRAFFIC SIGNAL
VALVE
WETLAND
WELL
TREE-CONIFEROUS
GUY WIRE ANCHOR
LIFT STATION
LIFT STATION CONTROL PANEL
MANHOLE-WATER
BASKETBALL POST
CULVERT END
SOIL BORING
ABBREVIATIONS
A ALGEBRAIC DIFFERENCE
ADJ ADJUST
ALT ALTERNATE
B-B BACK TO BACK
BLDG BUILDING
BMP BEST MANAGEMENT PRACTICE
BR BEGIN RADIUS
BV BUTTERFLY VALVE
CB CATCH BASIN
C&G CURB AND GUTTER
CIP CAST IRON PIPE
CIPP CURED-IN-PLACE PIPE
CL CENTER LINE
CL.CLASS
CMP CORRUGATED METAL PIPE
C.O.CHANGE ORDER
COMM COMMUNICATION
CSP CORRUGATED STEEL PIPE
CLVT CULVERT
DIA DIAMETER
DIP DUCTILE IRON PIPE
DWY DRIVEWAY
E EXTERNAL CURVE DISTANCE
ESMT EASEMENT
ELEC ELECTRIC
ELEV/EL ELEVATION
EOF EMERGENCY OVERFLOW
ER END RADIUS
EX EXISTING
FES FLARED END SECTION
F-F FACE TO FACE
FF FINISHED FLOOR
F&I FURNISH AND INSTALL
FM FORCEMAIN
FO FIBER OPTIC
F.O.FIELD ORDER
GRAN GRANULAR
GRAV GRAVEL
GU GUTTER
GV GATE VALVE
HDPE HIGH DENSITY POLYETHYLENE
HH HANDHOLE
HMA HOT MIX ASPHALT
HP HIGH POINT
HWL HIGH WATER LEVEL
HYD HYDRANT
I INVERT
K CURVE COEFFICIENT
L LENGTH
LO LOWEST OPENING
LP LOW POINT
LT LEFT
MH MANHOLE
MIN MINIMUM
MR MID RADIUS
NIC NOT IN CONTRACT
NMC NON-METALLIC CONDUIT
NTS NOT TO SCALE
NWL NORMAL WATER LEVEL
OHW ORDINARY HIGH WATER LEVEL
PC POINT OF CURVE
PCC PORTLAND CEMENT CONCRETE
PE PERMANENT EASEMENT
PED PEDESTRIAN, PEDESTAL
PERF PERFORATED PIPE
PERM PERMANENT
PI POINT OF INTERSECTION
PL PROPERTY LINE
PRC POINT OF REVERSE CURVE
PT POINT OF TANGENT
PVC POLYVINYL CHLORIDE PIPE
PVMT PAVEMENT
R RADIUS
RCP REINFORCED CONCRETE PIPE
RET RETAINING
R/W RIGHT-OF-WAY
RSC RIGID STEEL CONDUIT
RT RIGHT
SAN SANITARY SEWER
SCH SCHEDULE
SERV SERVICE
SHLD SHOULDER
STA STATION
STD STANDARD
STM STORM SEWER
TC TOP OF CURB
TE TEMPORARY EASEMENT
TEMP TEMPORARY
TNH TOP NUT HYDRANT
TP TOP OF PIPE
TYP TYPICAL
VCP VITRIFIED CLAY PIPE
VERT VERTICAL
VPC VERTICAL POINT OF CURVE
VPI VERTICAL POINT OF INTERSECTION
VPT VERTICAL POINT OF TANGENT
WM WATERMAIN
WS WATER SERVICE
AC ACRES
CF CUBIC FEET
CV COMPACTED VOLUME
CY CUBIC YARD
EA EACH
EV EXCAVATED VOLUME
LB POUND
LF LINEAR FEET
LS LUMP SUM
LV LOOSE VOLUME
SF SQUARE FEET
SV STOCKPILE VOLUME
SY SQUARE YARD
UNDERGROUND FIBER OPTIC
UNDERGROUND ELECTRIC
UNDERGROUND GAS
UNDERGROUND COMMUNICATION
OVERHEAD ELECTRIC
OVERHEAD COMMUNICATION
OVERHEAD UTILITY
953.53
EXISTING CONTOUR MINOR
EXISTING CONTOUR MAJOR
PROPOSED CONTOUR MINOR
PROPOSED CONTOUR MAJOR
PROPOSED GRADING LIMITS / SLOPE LIMITS
PROJECT LIMITS
PROPOSED SPOT ELEVATION
RISE:RUN (SLOPE)
OC OC OC OC
OU OU OU OU
STORM SEWER OUTLET STRUCTURE
STORM SEWER OVERFLOW STRUCTURE
STA:5+67.19
980.87
TRAFFIC ARM BARRIER
VENT PIPE
TILE INLET
TILE RISER
SIREN
DRIVE-THRU MICROPHONE
METER
ACCESS GRATE
FILL PIPE
DOWN SPOUT
BIRD FEEDER
ANTENNA
AIR CONDITION UNIT
NOTE:
EXISTING UTILITY INFORMATION SHOWN ON THIS PLAN HAS BEEN PROVIDED BY THE UTILITY OWNER. THE CONTRACTOR SHALL FIELD VERIFY
EXACT LOCATIONS PRIOR TO COMMENCING CONSTRUCTION AS REQUIRED BY STATE LAW. NOTIFY IOWA ONE CALL - 1-800-292-8989
THE SUBSURFACE UTILITY INFORMATION IN THIS PLAN IS UTILITY QUALITY LEVEL D UNLESS OTHERWISE NOTED. THIS UTILITY LEVEL WAS
DETERMINED ACCORDING TO THE GUIDELINES OF CI/ASCE 38-02, ENTITLED "STANDARD GUIDELINE FOR INVESTIGATING AND DOCUMENTING
EXISTING UTILITIES".
UTILITIES IDENTIFIED WITH A QUALITY LEVEL OTHER THAN D:
LINE TYPES FOLLOW THE FORMAT: UTILITY TYPE - QUALITY LEVEL
EXAMPLE: UNDERGROUND GAS, QUALITY LEVEL A
UTILITY QUALITY LEVEL (A,B,C,D) DEFINITIONS CAN BE FOUND IN CI/ASCE 38-22.
UTILITY QUALITY LEVELS:
LEVEL D - INFORMATION COMES SOLELY FROM EXISTING UTILITY RECORDS.
LEVEL C - SURVEYING ABOVE GROUND UTILITY FACILITIES, SUCH AS MANHOLES, VALVE BOXES, ETC; AND CORRELATING THIS INFORMATION WITH
EXISTING UTILITY RECORDS.
LEVEL B - THE USE OF SURFACE GEOPHYSICAL TECHNIQUES TO DETERMINE THE EXISTENCE AND HORIZONTAL POSITION OF UNDERGROUND
UTILITIES.
LEVEL A - THE USE OF NONDESTRUCTIVE DIGGING EQUIPMENT AT HORIZONTAL AND VERTICAL POSITION OF UNDERGROUND UTILITIES, AS WELL
AS THE TYPE, SIZE, CONDITION, MATERIAL, AND OTHER CHARACTERISTICS.
G-A G-A
UTILITY MARKER
VALVE VAULT
WET WELL
YARD HYDRANTY
BARRICADE PERMANENT
TILE OUTLET
EXISTING UTILITY LINES
l l l l l l l l l l
>>>>>
>>>>>>>>>>>>>>>>>>>>
>>>>>>>>
l l l l l l
l l l l l l l l l l l l
PROPOSED UTILITY LINES
>>>>>
SURVEY SYMBOLS
>>>>>>>>>>>>
SURVEY LINES
o o o
PAVEMENT MARKING
AUTO SPRINKLER CONNECTION
WETLAND DELINEATED MARKER
CONTROLLED ACCESS
BOUNDARY
CENTERLINE
EXISTING EASEMENT LINE
PROPOSED EASEMENT LINE
EXISTING LOT LINE
PROPOSED LOT LINE
EXISTING RIGHT-OF-WAY
PROPOSED RIGHT-OF-WAY
SETBACK LINE
SECTION LINE
BUSH LINE
TREE LINE
GUARD RAIL
FENCE-DECORATIVE
FENCE
RETAINING WALL
PIPE CASING
WATER SERVICE
WATERMAIN
STORM SEWER DRAIN TILE
STORM SEWER
SANITARY SERVICE
SANITARY SEWER
FORCEMAIN
WATER TEE
WATER CROSS
WATER SLEEVE
WATER CAP / PLUG
WATER VALVE
EXISTING TOPOGRAPHIC LINES
QUARTER LINE
SIXTEENTH LINE
TRAFFIC SIGNS
BOLLARD
TEMPORARY EASEMENT
GRAVEL
SIDEWALK PCC PAVEMENT
LIGHT POLE
VAULT
WW
BENCHMARK LOCATION
MONUMENT FOUND
CAST IRON MONUMENT
CONTROL POINT STONE MONUMENT
TRENCHLESS PIPE (PLAN VIEW)
TRENCHLESS PIPE (PROFILE VIEW)
ELECTRIC CAR CHARGE STATIONEV
H
F
CLVT
CO
B
B
AC
CP
L
C
E
G
H
U
S
D
W
MANHOLE-RECLAIMED WATERW
M
C
E
P
Y
WW
WS
V
V
U
TRASH
TILE
G
||||||||||||
>>>>>>
>>>>>>>>>>>>
l l l l l l
l l l l l l l l l l l l
>>>>>>>>>>
>>>>>>>>>>>>>>>>>>>>
WATER SERVICE
WATERMAIN
STORM SEWER DRAIN TILE
STORM SEWER
SANITARY SERVICE
SANITARY SEWER
FORCEMAIN
WR WR WR WR WR WR RECLAIMED WATER
SHEET
B
o
l
t
o
n
&
M
e
n
k
,
I
n
c
.
20
2
6
,
A
l
l
R
i
g
h
t
s
R
e
s
e
r
v
e
d
c H:
\
H
U
N
Z
I
\
2
4
X
1
3
5
5
0
5
0
0
0
\
C
A
D
\
C
3
D
\
1
3
5
5
0
5
G
1
0
1
.
d
w
g
8/
2
1
/
2
0
2
6
1
1
:
1
7
:
4
7
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HUNZIKER DEVELOPMENT
259/263 HYLAND
24X.135505.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100
Email: Ames@bolton-menk.com
www.bolton-menk.comR
G1.02
LEGEND 11
SHEET
B
o
l
t
o
n
&
M
e
n
k
,
I
n
c
.
20
2
6
,
A
l
l
R
i
g
h
t
s
R
e
s
e
r
v
e
d
c H:
\
H
U
N
Z
I
\
2
4
X
1
3
5
5
0
5
0
0
0
\
C
A
D
\
C
3
D
\
1
3
5
5
0
5
G
2
0
1
.
d
w
g
8/
2
1
/
2
0
2
6
1
1
:
1
7
:
5
4
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HUNZIKER DEVELOPMENT
259/263 HYLAND
24X.135505.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100
Email: Ames@bolton-menk.com
www.bolton-menk.comR
G2.01
GENERAL NOTES
STANDARD CONSTRUCTION NOTES:
1.ALL IMPROVEMENTS SHALL BE IN ACCORDANCE WITH THE MOST CURRENT EDITION OF THE IOWA STATEWIDE URBAN DESIGN AND SPECIFICATIONS (SUDAS) AND SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE
AND LOCAL LAWS AND ORDINANCES. THE CONTRACTOR SHALL HAVE A COMPLETE SET OF THE CURRENT SUDAS STANDARD SPECIFICATIONS ON SITE DURING ALL CONSTRUCTION ACTIVITIES.
2.ANY DEFECTIVE WORK CONDEMNED BY THE ENGINEER/OWNER SHALL BE REMOVED AND REPLACED AT THE CONTRACTOR'S EXPENSE IN ACCORDANCE WITH SECTION 1050, 1.08 'REMOVAL OF DEFECTIVE WORK' OF THE
STANDARDS SPECIFICATIONS. FAILURE TO REMOVE DEFECTIVE WORK MAY RESULT IN SUSPENSION OF OPERATIONS AND/OR WITHHOLDING OF PAYMENTS UNTIL DEFECTIVE WORK HAS BEEN REMOVED AND REPLACED.
3.THE CONTRACTOR SHALL PRESERVE ALL SURVEY CONTROL, LINE AND GRADE STAKES IN ACCORDANCE WITH SECTION 1050, 1.10 'LINE AND GRADE STAKES' OF THE STANDARD SPECIFICATIONS.
4.PRIOR TO MOBILIZING OFF OF THE JOB SITE, THE CONTRACTOR SHALL NOTIFY THE ENGINEER/OWNER TO REQUEST A FINAL INSPECTION IN ACCORDANCE WITH SECTION 1050, 1.14 'FINAL INSPECTION AND ACCEPTANCE'
OF THE STANDARD SPECIFICATIONS.
5.THE CONTRACTOR SHALL PROCURE ALL NECESSARY PERMITS AND LICENSES IN ACCORDANCE WITH SECTION 1070, 1.03 'PERMITS AND LICENSES' OF THE STANDARD SPECIFICATIONS.
6.THE CONTRACTOR IS RESPONSIBLE FOR SITE SAFETY AND COMPLYING WITH ALL CURRENT AND FUTURE FEDERAL AND STATE OSHA REQUIREMENTS IN ACCORDANCE WITH SECTION 1070, 2.02 'CONVENIENCE AND
SAFETY' OF THE STANDARD SPECIFICATIONS.
7.IN ACCORDANCE WITH SECTION 1070, 2.08 'PROTECTION OF PROPERTY' OF THE STANDARD SPECIFICATIONS, THE CONTRACTOR SHALL CONTINUOUSLY MAINTAIN ADEQUATE PROTECTION OF ALL ITS WORK FROM
DAMAGE AND SHALL PROTECT THE JURISDICTION'S PROPERTY AND ADJACENT PRIVATE PROPERTY FROM INJURY OR LOSS ARISING IN CONNECTION WITH THE WORK. THE CONTRACTOR SHALL REPAIR OR RESTORE ANY
SUCH DAMAGE, INJURY, OR LOSS TO JURISDICTION PROPERTY OR ADJACENT PROPERTY. THE CONTRACTOR SHALL PROTECT TREES AND OTHER PROPERTY NOT MARKED FOR REMOVAL.
8.THE CONTRACTOR SHALL PRESERVE OR REPLACE ALL PROPERTY MONUMENTS ON THE PROJECT SITE IN ACCORDANCE WITH SECTION 1070, 2.09 'LAND MONUMENTS' OF THE STANDARD SPECIFICATIONS.
9.THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING SITE CLEANLINESS. UPON REQUEST BY THE ENGINEER/OWNER, THE CONTRACTOR SHALL, AT ITS EXPENSE, CLEANUP AND REMOVE ALL REFUSE AND UNUSED
MATERIALS OF ANY KIND RESULTING FROM THE WORK INCLUDING CLEANING AND SWEEPING OF ADJACENT STREETS. UPON FAILURE DO SO WITHIN THREE WORKING DAYS AFTER SUCH REQUEST BY THE
ENGINEER/OWNER, THE WORK MAY BE DONE BY THE OWNER AND THE COST THEREOF CHARGED TO THE CONTRACTOR AND DEDUCTED FROM ITS FINAL PAYMENT IN ACCORDANCE WITH SECTION 1070, 2.15 'FINISHING
AND CLEANUP REQUIREMENTS' OF THE STANDARD SPECIFICATIONS.
10.THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER/OWNER FOR APPROVAL A PROGRESS SCHEDULE THAT WILL ENSURE THE COMPLETION OF THE PROJECT WITHIN THE TIME SPECIFIED. IF IT APPEARS THE RATE OF
PROGRESS IS SUCH THAT THE CONTRACT WILL NOT BE COMPLETED WITHIN THE TIME ALLOWED, OR IF THE WORK IS NOT BEING EXECUTED IN A SATISFACTORY AND WORKMANLIKE MANNER, THE ENGINEER/OWNER
MAY ORDER THE CONTRACTOR TO TAKE SUCH STEPS AS NECESSARY TO COMPLETE THE WORK AS SPECIFIED IN THE CONTRACT IN ACCORDANCE WITH SECTION 1080, 1.03 'WORK PROGRESS AND SCHEDULE' OF THE
STANDARD SPECIFICATIONS.
11.NO OUTDOOR LIGHTING SHALL BE INSTALLED UNLESS APPROVED BY THE DEPARTMENT OF PLANNING AND HOUSING. PRIOR TO INSTALLATION OF ANY OUTDOOR LIGHTING FIXTURES, SUFFICIENT INFORMATION AS
DESCRIBED IN CITY OF AMES CODE SECTION 29.411 10(A) OR 10(B) ABOVE SHALL BE SUBMITTED TO THE DEPARTMENT IN ORDER TO DETERMINE COMPLIANCE WITH THE OUTDOOR LIGHTING CODE.
UTILITY COORDINATION NOTES:
1.THE CONTRACTOR IS REQUIRED TO UTILIZE THE UTILITY ONE-CALL SERVICE AT (800) 292-8989 TO LOCATE EXISTING UNDERGROUND UTILITIES AT LEAST 48 HOURS PRIOR TO EXCAVATING ANYWHERE ON THE PROJECT.
2.ANTICIPATED UTILITY CONFLICTS HAVE BEEN IDENTIFIED AND EACH RESPECTIVE UTILITY OWNER HAS BEEN INFORMED OF THE POTENTIAL CONFLICTS. THE CONTRACTOR SHALL PROTECT THE EXISTING UTILITIES TO
REMAIN WITHIN THE PROJECT SITE.
3.THE LOCATION OF ALL AERIAL AND UNDERGROUND UTILITIES MAY NOT BE INDICATED ON THESE PLANS. WORK SHALL BE COMPLETED IN ACCORDANCE WITH SECTION 1070, 2.07 'PROTECTION OF ABOVEGROUND AND
UNDERGROUND FACILITIES' OF THE STANDARD SPECIFICATIONS. THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY OF ANY DAMAGE TO EXISTING UTILITIES.
4.IF A CONFLICT IS DISCOVERED BY THE CONTRACTOR, NOTIFY THE ENGINEER IMMEDIATELY AND COORDINATE WITH OWNER OF UTILITY TO RESOLVE CONFLICT.
PROJECT NOTES:
1.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING CONSTRUCTION STAKING IN ACCORDANCE WITH SECTION 11,010 OF THE STANDARD SPECIFICATIONS AND SHALL COMPLY WITH IOWA CODE 355 AND IOWA
ADMINISTRATIVE CODE SECTION 193C FOR THE REPLACEMENT OF ALL DISTURBED MONUMENTS WITHIN THE PROJECT AREA.
2.CONTRACTOR SHALL PROPERLY SECURE PROJECT SITE AT THE END OF EACH DAY.
3.CONTRACTOR OPERATIONS CREATING OBJECTIONABLE LEVELS OF NOISE SHALL NOT BEGIN PRIOR TO 7:00 AM AND SHALL END PRIOR TO 7:00 PM.
4.ALL DISTURBED AREAS SHALL BE SEEDED AND/OR MULCHED (DEPENDING ON DATE) UPON COMPLETION OF GRADING.
5.ALL UTILITY SERVICES (SANITARY, WATER, AND SUMP) SHALL BE INSTALLED BY A PLUMBER LICENSED BY THE CITY OF AMES.
6.ALL UTILITY TRENCHES SHALL BE CAREFULLY BACKFILLED IN 6-IN LIFTS, COMPACTED TO 95% OF MAXIMUM STANDARD PROCTOR DENSITY. DENSITY REPORTS ARE TO BE SUBMITTED TO THE CITY OF AMES WITHIN 7 DAYS
OF TRENCH DENSITY TESTING. ANY FAILING TEST AREAS SHALL BE RE-EXCAVATED AND RE-TESTED.
7.THE CONTRACTOR SHALL LIMIT THEIR ACCESS TO THE PROJECT SITE TO THE STABILIZED ENTRANCE LOCATIONS SHOWN IN THE SWPPP.
8.THE CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS DEPARTMENT, THE DEVELOPER, AND BOLTON & MENK, INC. ONE WEEK PRIOR TO THE START OF ANY CONSTRUCTION.
9.ANY TREES AND CROPS SHALL BE REMOVED ONLY BY APPROVAL OF THE ENGINEER/OWNER.
STORM WATER POLLUTION PREVENTION PLAN NOTES:
1.CONTRACTOR SHALL FOLLOW ALL REQUIREMENTS OF IDNR NPDES GENERAL PERMITS #2.
2.CONTRACTOR SHALL MINIMIZE THE AMOUNT OF SOIL EXPOSED DURING CONSTRUCTION ACTIVITY
3.STABILIZATION OF DISTURBED AREAS MUST, AT A MINIMUM, BE INITIATED IMMEDIATELY WHENEVER ANY CLEARING, GRADING, EXCAVATING OR OTHER EARTH DISTURBING ACTIVITIES HAVE PERMANENTLY CEASED ON
ANY PORTION OF THE SITE OR TEMPORARILY CEASED ON ANY PORTION OF THE SITE AND WILL NOT RESUME FOR A PERIOD EXCEEDING 14 CALENDAR DAYS. IN DROUGHT-STRICKEN AREAS AND AREAS THAT HAVE
RECENTLY RECEIVED SUCH HIGH AMOUNTS OF RAIN THAT SEEDING WITH FIELD EQUIPMENT IS IMPOSSIBLE AND INITIATING VEGETATIVE STABILIZATION IMMEDIATELY IS INFEASIBLE, ALTERNATIVE STABILIZATION
MEASURES MUST BE EMPLOYED AS SPECIFIED BY THE DEPARTMENT. IN LIMITED CIRCUMSTANCES, STABILIZATION MAY NOT BE REQUIRED IF THE INTENDED FUNCTION OF A SPECIFIC AREA OF THE SITE NECESSITATES
THAT IT REMAIN DISTURBED.
4.MINIMIZE THE DISCHARGE OF POLLUTANTS FROM EQUIPMENT AND VEHICLE WASHING, WHEEL WASH WATER AND OTHER WASH WATERS. WASH WATERS MUST BE TREATED IN A SEDIMENT BASIN OR ALTERNATIVE
CONTROL THAT PROVIDES EQUIVALENT OR BETTER TREATMENT PRIOR TO DISCHARGE;
5. MINIMIZE THE EXPOSURE OF BUILDING MATERIALS, BUILDING PRODUCTS, CONSTRUCTION WASTES, TRASH, LANDSCAPE MATERIALS, FERTILIZERS, PESTICIDES, HERBICIDES, DETERGENTS, SANITARY WASTE AND OTHER
MATERIALS PRESENT ON THE SITE TO PRECIPITATION AND STORM WATER. MINIMIZATION OF EXPOSURE IS NOT REQUIRED IN CASES WHERE THE EXPOSURE TO PRECIPITATION AND TO STORM WATER WILL NOT RESULT
IN A DISCHARGE OF POLLUTANTS, OR WHERE EXPOSURE OF A SPECIFIC MATERIAL OR PRODUCT POSES LITTLE RISK OF STORM WATER CONTAMINATION (SUCH AS FINAL PRODUCTS AND MATERIALS INTENDED FOR
OUTDOOR USE)
6. MINIMIZE THE DISCHARGE OF POLLUTANTS FROM SPILLS AND LEAKS AND IMPLEMENT CHEMICAL SPILL AND LEAK PREVENTION AND RESPONSE PROCEDURES.
7.CONCRETE WASHOUTS SHALL BE PROVIDED ON SITE.
8.QUALIFIED PERSONNEL SHALL INSPECT DISTURBED AREAS OF THE CONSTRUCTION SITE THAT HAVE NOT BEEN STABILIZED WITH A PERENNIAL, VEGETATIVE COVER OF SUFFICIENT DENSITY TO PRECLUDE EROSION AT
LEAST ONCE EVERY SEVEN CALENDAR DAYS. UNLESS EROSION IS EVIDENT OR OTHER CONDITIONS WARRANT THEM, REGULAR INSPECTIONS ARE NOT REQUIRED ON AREAS THAT HAVE BEEN STABILIZED WITH A
PERENNIAL, VEGETATIVE COVER OF SUFFICIENT DENSITY TO PRECLUDE EROSION.
9.DISTURBED AREAS AND AREAS USED FOR STORAGE OF MATERIALS THAT ARE EXPOSED TO PRECIPITATION SHALL BE INSPECTED FOR EVIDENCE OF, OR THE POTENTIAL FOR, POLLUTANTS ENTERING THE DRAINAGE
SYSTEM.
10.EROSION AND SEDIMENT CONTROL MEASURES IDENTIFIED IN THE PLAN SHALL BE OBSERVED TO ENSURE THAT THEY ARE OPERATING CORRECTLY. WHERE DISCHARGE LOCATIONS OR POINTS ARE ACCESSIBLE, THEY
SHALL BE INSPECTED TO ASCERTAIN WHETHER EROSION CONTROL MEASURES ARE EFFECTIVE IN PREVENTING SIGNIFICANT IMPACTS TO RECEIVING WATERS. LOCATIONS WHERE VEHICLES ENTER OR EXIT THE SITE
SHALL BE INSPECTED FOR EVIDENCE OF OFFSITE SEDIMENT TRACKING.
11. BASED ON THE RESULTS OF THE INSPECTION, POLLUTION PREVENTION MEASURES IDENTIFIED IN THE PLANS SHALL BE REVISED AT THE CONSTRUCTION SITE AS APPROPRIATE AS SOON AS PRACTICABLE AFTER THE
INSPECTION AND TO THE PLAN AS SOON AS PRACTICABLE AFTER THE INSPECTION BUT IN NO CASE MORE THAN 7 CALENDAR DAYS FOLLOWING THE INSPECTION. IF THE PERMITTEE DETERMINES THAT MAKING THESE
CHANGES AT THE CONSTRUCTION SITE OR TO THE PLAN LESS THAN 72 HOURS AFTER THE INSPECTION IS IMPRACTICABLE, THE PERMITTEE SHALL DOCUMENT IN THE PLAN WHY IT IS IMPRACTICABLE AND INDICATE AN
ESTIMATED DATE BY WHICH THE CHANGES WILL BE MADE.
12. A REPORT SUMMARIZING THE SCOPE OF THE INSPECTION, NAME(S) AND QUALIFICATIONS OF PERSONNEL MAKING THE INSPECTION, THE DATE(S) OF THE INSPECTION, MAJOR OBSERVATIONS RELATING TO THE
IMPLEMENTATION OF THE STORM WATER POLLUTION PREVENTION PLAN, AND ACTIONS TAKEN SHALL BE MADE AND RETAINED AS PART OF THE STORM WATER POLLUTION PREVENTION PLAN FOR AT LEAST THREE
YEARS AFTER FINAL STABILIZATION HAS BEEN ACHIEVED AND A NOTICE OF DISCONTINUATION HAS BEEN SUBMITTED TO THE DEPARTMENT.
13.EROSION CONTROL MEASURES SHOWN ON THE PLAN ARE THE MINIMUM REQUIRED TO BE INSTALLED. ADDITIONAL MEASURES MAY BE REQUIRED TO PROTECT/STABILIZE THE SITE. ADDITIONAL CONTROLS MAY
INCLUDE, BUT ARE NOT LIMITED TO SILT FENCE, COMPOST BLANKETS, FILTER SOCKS, RIPRAP, FLOW TRANSITION MAPS, ETC. ANY ADDITIONAL CONTROL MEASURE REQUIRED SHALL BE INSTALLED BY THE CONTRACTOR
AT NO ADDITIONAL COSTS TO THE OWNER.
PAVING NOTES:
1.PAVING SHALL BE COMPLETED IN ACCORDANCE WITH DIVISION 7 OF THE SPECIFICATIONS.
2.THE CONTRACTOR SHALL SUBMIT INFORMATION TO THE ENGINEER FOR APPROVAL IN ACCORDANCE WITH SECTIONS 1050, 1.05 AND 7010, 1.03 OF THE STANDARD SPECIFICATIONS:
a.PCC PAVING MIX DESIGN
b.MATURITY CURVES FOR PAVING MIXES AND MATURITY READING RESULTS
3.PAVEMENT DESIGN SHALL INCLUDE A MINIMUM STRENGTH OF 4,000 PSI.
4.QUALITY CONTROL SHALL BE PERFORMED IN ACCORDANCE WITH SECTION 7010, 3.08 'QUALITY CONTROL' OF THE STANDARD SPECIFICATIONS.
5.IN ACCORDANCE WITH SECTION 7010, 3.02, K OF THE STANDARD SPECIFICATIONS, THE CONTRACTOR SHALL CLEAN AND SEAL ALL JOINTS BEFORE ANY PORTION OF THE NEWLY CONSTRUCTED PAVEMENT IS OPENED TO
THE CONTRACTOR'S EQUIPMENT.
6.THE CONTRACTOR SHALL OPEN NEWLY CONSTRUCTED PAVEMENT TO TRAFFIC IN ACCORDANCE WITH SECTION 7010, 3.06 OF THE STANDARD SPECIFICATIONS. ALL NEWLY CONSTRUCTED PAVEMENT SHALL BE
SCRAPPED AND SWEPT CLEAN PRIOR TO OPENING TO TRAFFIC.
7.THE CONTRACTOR SHALL PROTECT PAVEMENT IN ACCORDANCE WITH SECTION 7010, 3.05 OF THE STANDARD SPECIFICATIONS AND SHALL NOT USE NEWLY CONSTRUCTED PAVEMENT AS AN AREA OF STOCKPILING
MATERIALS.
8.DROP CURBS SHALL BE CONSTRUCTED AT INTERSECTION FOR PEDESTRIAN RAMPS.
9.ALL UTILITY FIXTURES (WATER VALVE BOXES, MANHOLES, AND STORM SEWER INTAKES) SHALL BE SET TO THEIR CORRESPONDING PAVEMENT ELEVATIONS.
10.PARKING LOT JOINTING PLAN SHALL BE SUBMITTED BY THE CONTRACTOR TO THE ENGINEER/OWNER FOR REVIEW AT LEAST 7 DAYS PRIOR TO PAVING OPERATIONS. NO KEYWAY JOINTS SHALL BE ALLOWED. AT A
MINIMUM ALL COLD JOINTS SHALL BE TIED TOGETHER USING A DW JOINT IN ACCORDANCE WITH SECTION 7010 AND DETAIL PV-101.
11.LONGITUDINAL JOINTS SHALL BE TIED TOGETHER USING CONTRACTION JOINT, “L” TYPE SUDAS JOINT.
12.CONCRETE JOINTS SHALL HAVE A LENGTH TO WIDTH RATIO NO LARGER THAN 1:1.5. MAXIMUM JOINT SPACING SHALL BE 12' IN ANY DIRECTION. JOINT DEPTH SHALL BE A MINIMUM DEPTH OF 1/3 OF PAVEMENT
THICKNESS.
TRAFFIC CONTROL NOTES:
1.TRAFFIC CONTROL LAYOUTS SHOWN ON THESE PLANS ARE GENERAL TRAFFIC CONTROL LAYOUTS FOR INFORMATION ONLY.
2.THE CONTRACTOR SHALL DEVELOP A TRAFFIC CONTROL PLAN IN ACCORDANCE WITH SECTION 1070, 2.06 'TRAFFIC CONTROL' OF THE STANDARD SPECIFICATIONS. ANY TRAFFIC CONTROL DEVICES OR SAFETY
EQUIPMENT NEEDED TO CONSTRUCT THE PROJECT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL SUBMIT A CONSTRUCTION PHASING AND TRAFFIC CONTROL PLAN WITH PLANNED
DETOURS, IF APPLICABLE, TO THE ENGINEER FOR APPROVAL BEFORE THE START OF ANY CONSTRUCTION ACTIVITIES.
3.IF NECESSARY, STREETS WILL BE CLOSED IN ACCORDANCE WITH SECTION 1070, 2.06 'TRAFFIC CONTROL' OF THE STANDARD SPECIFICATIONS.
4.ALL TRAFFIC CONTROL PLANS MUST BE REVIEWED AND APPROVED BY CITY OF AMES PUBLIC WORKS TRAFFIC DIVISION (DAMION PREGITZER, 515-509-5189). COORDINATE WITH CITY OF AMES PUBLIC WORKS TRAFFIC
PRIOR TO PLACEMENT OF TRAFFIC CONTROL DEVICES AND SIGNS FOR EACH STAGE OF THE PROJECT.
5.ALL TRAFFIC CONTROL DEVICES SHALL BE FURNISHED, ERECTED, MAINTAINED, AND REMOVED BY THE CONTRACTOR.
6.PORTABLE MOUNTINGS FOR WARNING SIGNS MAY BE USED FOR TEMPORARY INSTALLATIONS OF 3 DAYS OR LESS ALL OTHER TRAFFIC CONTROL SHALL BE POST MOUNTED.
7.THE PROPOSED SIGNAGE MAY BE MODIFIED TO MEET FIELD CONDITIONS, PREVENT OBSTRUCTIONS AND TO ACCOMMODATE CONSTRUCTION SCHEDULING UPON APPROVAL OF THE PROJECT ENGINEER
8.ORANGE SAFETY FENCE SHALL BE PLACED ENTIRELY ACROSS THE TRAVELED PORTION OF THE ROADWAY AT ALL LOCATIONS WHERE TYPE III BARRICADES WITH "ROAD CLOSED" SIGNS ARE USED.
9.SIGNAGE MAINTENANCE SHALL BE CONSIDERED INCIDENTAL TO TRAFFIC CONTROL AND REQUIRED AS DIRECTED BY THE ENGINEER.
10.ALL CONSTRUCTION SIGNS SHALL BE DIAMOND GRADE FLUORESCENT ORANGE OR WHITE V.I.P. SHEETING OR EQUIVALENT. (IOWA DOT TYPE VII SHEETING).
11.THE CONTRACTOR SHALL CONTACT THE CITY OF AMES TRAFFIC DIVISION (DAMION PREGITZER, 515-509-5189) TO REMOVE ALL PERMANENT STREET SIGNS CONFLICTING WITH PROPOSED IMPROVEMENTS. THE
CONTRACTOR SHALL REMOVE ALL OTHER SIGNS AS DETERMINED BY THE ENGINEER AND THEY SHALL REMAIN THE PROPERTY OF THE RESPECTIVE OWNERS. THIS WORK SHALL BE CONSIDERED INCIDENTAL TO OTHER
WORK.
12.AT THE TIME OF INITIAL SETUP OR AT THE TIME OF MAJOR STAGE CHANGES, 100 PERCENT OF EACH TYPE OF DEVICE (SIGNS, CONES, TUBULAR MARKERS, DRUMS, BARRICADES, VERTICAL PANELS, CHANGEABLE
MESSAGE SIGNS, AND PAVEMENT MARKINGS) SHALL BE CLASSIFIED AS ACCEPTABLE BY THE REQUIREMENT OF THE AMERICAN TRAFFIC SAFETY SERVICES ASSOCIATION (ATSSA), "QUALITY STANDARD FOR WORK ZONE
TRAFFIC CONTROL DEVICES 1992." THROUGHOUT THE DURATION OF THE PROJECT, UNACCEPTABLE DEVICES OR SITUATIONS THAT ARE FOUND ON THE JOBSITE AS DETERMINED BY BEFORE MENTIONED PUBLICATION
SHALL BE REPLACED OR THE SITUATION CORRECTED WITHIN 12 HOURS OF INITIAL NOTIFICATIONS BY THE ENGINEER.
13.AT EACH SIDEWALK CLOSURE LOCATION PLACE TYPE II BARRICADES WITH "SIDEWALK CLOSED" SIGNS AT EACH CLOSURE END AND PLACE "SIDEWALK CLOSED AHEAD" SIGNS ALONG THE SIDEWALK AT NEAREST STREET
INTERSECTIONS ON EACH SIDE OF THE CLOSURE LOCATION IN ACCORDANCE WITH THE MUTCD.
GRADING NOTES:
1.ALL GRADING OPERATIONS SHALL BE COMPLETED IN ACCORDANCE WITH DIVISION 2 OF THE SPECIFICATIONS
2.THE PROPOSED CONTOURS ARE SHOWN ARE TO FINISH GROUND/TOP OF PAVEMENT
3.CONTRACTOR SHALL GRADE ALL AREAS IN THE PAVEMENT BOX TO SUBGRADE, AND ALL OTHER AREAS TO FINISH GROUND.
4.AREAS WITHIN THE RIGHT-OF-WAY SHALL BE COMPACTED TO NO LESS THAN 95% OF MAXIMUM STANDARD PROCTOR DENSITY AT A MOISTURE CONTENT OF -1% TO +3% ABOVE OPTIMUM.
5.AREAS OUTSIDE THE RIGHT-OF-WAY SHALL BE FINAL GRADED TO WITHIN 0.2' OF PLAN GRADE. AREAS WITHIN THE RIGHT-OF-WAY SHALL BE FINAL GRADED TO WITHIN 0.1' OF PLAN GRADE.
6.ALL TOPSOIL STRIPPED SHALL BE RESPREAD ON LOT(S).
7.THE CONTRACTOR SHALL SHAPE GRADED AREAS TO MAINTAIN SURFACE DRAINAGE AT ALL TIMES.
8.THE CONTRACTOR SHALL BACKFILL CURBS AS SOON AS POSSIBLE UPON COMPLETION OF PAVING
9.DEWATERING (IF NECESSARY) IS CONTRACTOR'S RESPONSIBILITY AND SHALL BE CONSIDERED INCIDENTAL.
10.CONTRACTOR SHALL MINIMIZE COMPACTION OF TOPSOIL TO THE EXTENT PRACTICABLE.
SANITARY SEWER NOTES:
1.SANITARY SEWER INSTALLATION SHALL BE COMPLETED IN ACCORDANCE WITH DIVISIONS 3, 4, AND 6 OF THE SPECIFICATIONS
2.SANITARY SEWER BEDDING SHALL BE CLASS F-3 BEDDING UNLESS OTHERWISE SPECIFIED.
STORM SEWER NOTES:
1.STORM SEWER INSTALLATION SHALL BE IN ACCORDANCE WITH DIVISIONS 3, 4, AND 6 OF THE SPECIFICATIONS.
2.STORM SEWER SHALL BE BEDDING SHALL BE CLASS R-2
3.MANHOLE CASTINGS IN SHALL BE 2 PIECE FIXED CASTINGS. ALL MANHOLE CASTINGS SHALL BE BOLTED TO THE STRUCTURE AT ALL ATTACHMENT HOLE LOCATIONS IN THE CASTING.
4.RCP PLUGS SHALL BE CONSIDERED INCIDENTAL TO STORM SEWER CONSTRUCTION.
5.THE CONTRACTOR SHALL REPAIR ANY FIELD TILE ENCOUNTERED DURING CONSTRUCTION OF THIS PROJECT (WHETHER SHOWN ON THE PLAN OR NOT) BY SPLICING OR CONNECTING THE TILE TO THE NEW STORM SEWER
SYSTEM.
WATER MAIN NOTES:
1.WATER MAIN INSTALLATION SHALL BE COMPLETED IN ACCORDANCE WITH DIVISIONS 3 AND 5 OF THE SPECIFICATIONS.
2.WATER VALVE BOXES SHALL BE CAST IRON IN ACCORDANCE WITH SECTION 5020 OF THE SPECIFICATIONS, OR "TRENCH ADAPTOR" WITH CAST IRON TOP SECTION. AN EXTENSION SHAFT SHALL BE FURNISHED THAT
POSITIONS THE VALVE OPERATING NUT WITHIN 2 FEET OF PROPOSED GRADE.
3.METAL WATER MAIN FITTINGS AND METAL ACCESSORIES SHALL BE WRAPPED WITH 8-MIL POLYETHYLENE SHEETING AND SECURED WITH TAPE.
4.WATER MAIN SHALL BE INSTALLED WITH 5.5 FEET COVER (MINIMUM).
5.WATER MAIN BEDDING SHALL BE CLASS P-1
6.CURB STOP BOXES ON WATER SERVICES SHALL BE LOCATED AS SHOWN ON THE PLANS.
7.WATER MAIN VALVES SHALL BE OPERATED BY CITY OF AMES PERSONNEL ONLY.
8.CRITICAL CROSSINGS SHALL CONFORM TO CITY OF AMES SUPPLEMENTAL SPECIFICATIONS.
9.FIRE AND DOMESTIC SERVICE BID ITEMS SHALL INCLUDE ALL FITTING AND VALVES REQUIRED TO CONNECT TO THE MAIN AND THE BUILDING.
12
SHEET
B
o
l
t
o
n
&
M
e
n
k
,
I
n
c
.
20
2
6
,
A
l
l
R
i
g
h
t
s
R
e
s
e
r
v
e
d
c H:
\
H
U
N
Z
I
\
2
4
X
1
3
5
5
0
5
0
0
0
\
C
A
D
\
C
3
D
\
1
3
5
5
0
5
G
2
0
1
.
d
w
g
8/
2
1
/
2
0
2
6
1
1
:
1
7
:
5
4
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HUNZIKER DEVELOPMENT
259/263 HYLAND
24X.135505.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100
Email: Ames@bolton-menk.com
www.bolton-menk.comR
G2.02
DETAILS
BOLLARD GUARD POST
NOT TO SCALE
18"
6"
3'
-
0
"
4'
-
0
"
CONCRETE
ONE WRAP OF
30# ROOFING FELT
8" DIA CONCRETE-FILLED
STANDARD STEEL BOLLARD
EXISTING
GRADE
4"R
PLATE NO.R
LAST REVISION:
04-2021
9-300
6" PCC
SUBGRADE PREPARATION (2112) (INCIDENTAL)
A CONCRETE PAVEMENT
NOT TO SCALE
2" X 6" RAIL WITH
HEAVY DUTY HANGER
SECURED TO POST (TYP.)
CIRCULAR METAL FENCE POST
2" X 6" P.T. RAIL
1" X 6" CEDAR
TYP. SPACINGEQ.6"4"6"EQ.TYP. SPACING
TRASH ENCLOSURE TOP VIEW
(NOT TO SCALE)
TWO HINGED DOORSWITH CENTER LATCH
8'
0.75'
9.5'
TRASH ENCLOSURE ELEVATION
(NOT TO SCALE)
SLAB
TIE DOWN TO
CONCRETE WITH
GALVANIZED POST
BRACKETS (TYP.) OR
IN CONCRETE FOOTING
CONT. 2" X 6" P.T.HORIZ. RAIL TOPAND BOTTOMBETWEEN POSTS
FENCE POST
1" X 6" CEDAR
VERT. SLATSEQ. SPACE (STAGGEROPPOSITE FACE)
3"
8'
7.
2
5
'
6"
4' MAX.
14
'
NOTE: OTHER ENCLOSURES MAY BE APPROVED BY OWNER.
0.75'
B TRASH ENCLOSURE
NOT TO SCALE
SITE DATA
BUILDING A (SOUTH LOT)
TOTAL LOT AREA 11,798 SF 0.27 ACRES
DISTURBED AREA 11,798 SF 0.27 ACRES
PERVIOUS AREA 4,056 SF 0.09 ACRES
IMPERVIOUS DATA
BUILDING(S) SIZE 6,475 SF 0.15 ACRES
PAVEMENT AREA 1,267 SF 0.03 ACRES
TOTAL IMPERVIOUS AREA 7,742 SF 0.18 ACRES
PERCENTAGES
IMPERVIOUS 66%
PERVIOUS 34%
TOTAL 100%
BUILDING B (NORTH LOT)
TOTAL LOT AREA 20,292 SF 0.47 ACRES
DISTURBED AREA 20,292 SF 0.47 ACRES
PERVIOUS AREA 7,426 SF 0.17 ACRES
IMPERVIOUS DATA
BUILDING(S) SIZE 6,955 SF 0.16 ACRES
PAVEMENT AREA 5,911 SF 0.14 ACRES
TOTAL IMPERVIOUS AREA 12,866 SF 0.30 ACRES
PERCENTAGES
IMPERVIOUS 63%
PERVIOUS 37%
TOTAL 100%
PARKING (PER BUILDING)
BUILDING A (SOUTH)
BUILDING SIZE 6475 SF
STUDIO UNIT
3 UNITS
1 STALLS/UNIT
3 REQUIRED STALLS
1 BEDROOM UNIT
4 UNITS
1 STALLS/UNIT
4 REQUIRED STALLS
2 BEDROOM UNIT
6 UNITS
1 STALLS/UNIT
6 REQUIRED STALLS
TOTAL REQUIRED STALLS PER BUILDING A 13 STALLS
TOTAL PROVIDED STALLS IN BUILDING A 13 STALLS
REQUIRED ADA STALLS 1 STALL
PROVIDED ADA STALLS 1 STALL
BUILDING B (NORTH)
BUILDING SIZE 6955 SF
1 BEDROOM UNIT
10 UNITS
1 STALLS/UNIT
10 REQUIRED STALLS
2 BEDROOM UNIT
9 UNITS
1 STALLS/UNIT
9 REQUIRED STALLS
TOTAL REQUIRED STALLS PER BUILDING A 19 STALLS
TOTAL PROVIDED STALLS IN BUILDING A 21 STALLS
REQUIRED ADA STALLS 1 STALL
PROVIDED ADA STALLS 1 STALL
13
LOT 1
0.27 ACRES
11,798 SQ FT
D
C
M
M
D
GGGGGG
>>>>>>>>>>>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>>>>>>>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
G G G G G G G G
l l l l l l l l l l l l l l l
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
945
950
955
941
942
943
944
946
947
948
949
951
952
953
954
956
935
934
936
937
938
945
950
955
94
1
942
943
944
946
947
948
949
951
952
953
954
956
955
951
952953
95
4
95
6
947
94
5
94
4
946
93
5
940
945
950
955
93
6
937
93
8
93
9
94
1
942
94
3
94
4
94
6
947
948
949
951
95
2
953
954
956
960
957
958
959
961
941
942
943
HY
L
A
N
D
A
V
E
DISCONNECT EXISTING
WATER SERVICE AT MAIN
(FIELD VERIFY DEPTH)
REMOVE TREE
REMOVE EXISTING RETAINING WALLS
X X X X XXX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
X
X
XXXXXXXXXXXXXXX
X
X
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XX
X X X X X X X X X X X X X X X X X X X XX
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
SHIFTED PROPERTY LINE
EXISTING PROPERTY LINE
259 N HYLAND AVE
GA
R
A
G
E
X
X
X
X
X
X
X
X
X
X
XX X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
REMOVE GAS SERVICE
REMOVE EXISTING RETAINING WALL
FULL DEPTH PATCH, 100 SY
REMOVE 60 LF OF EXISTING CURB & GUTTER
REMOVE EXISTING HOUSE
REMOVE GAS SERVICE
S88°53'36"W 137.00
N1
°
0
2
'
2
2
"
W
7
9
.
3
7
S0
°
5
9
'
5
6
"
E
8
0
.
0
0
S89°00'04"W 137.05
NOTE:
CONTRACTOR SHALL FIND EXISTING
SANITARY SEWER SERVICE FOR EACH
BUILDING AND ABANDON AT THE
BACK OF CURB.
SHEET
B
o
l
t
o
n
&
M
e
n
k
,
I
n
c
.
20
2
6
,
A
l
l
R
i
g
h
t
s
R
e
s
e
r
v
e
d
c H:
\
H
U
N
Z
I
\
2
4
X
1
3
5
5
0
5
0
0
0
\
C
A
D
\
C
3
D
\
1
3
5
5
0
5
C
1
0
1
.
d
w
g
8/
2
1
/
2
0
2
6
1
1
:
1
8
:
1
0
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HUNZIKER DEVELOPMENT
259/263 HYLAND
24X.135505.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100
Email: Ames@bolton-menk.com
www.bolton-menk.comR
C1.01
EXISTING CONDITIONS & REMOVALSFEETSCALE
0 10 20
HORZ.
R
LEGEND:
GRAVEL REMOVAL
PAVEMENT REMOVAL
SIDEWALK REMOVAL
ASPHALT/CONCRETE SAW CUT
14
LOT 2
0.47 ACRES
20,292 SQ FT
D
C
H
H
C
S S
S
M
M
M
OEOE
OE OE OE OE OE OE OE OE OE OE OE
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>>>>>>>>>
>
>
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>>>>>>>>>>>>>>
>
G G G G G G G G
E
E
E
E
E
E
E
E
E
E
E
E
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
F
F
F
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
FFFFFF
F
F
FFFFFFFFFFFFFF
G
G
S
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
llllllllllll
93
0
935
940
945
927 92
8
92
9
93
1
932
933
934
936
937
938
939
941
942
943
944
946
947
930
935
928
929
931
932
933
934
936
937
938
945
950
94
1
942
943
944
946
947
948
949
951
952
953
955
951
952953
95
4
947
94
5
94
4
946
935
940
932
933
934
936
937
938
939
941
942
943
OAKLAND ST
HY
L
A
N
D
A
V
E
HY
L
A
N
D
A
V
E
REMOVE EXISTING RETAINING WALLS
X
X
X
X
X
X
X
X
X
X
X
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
X
X
XXXXXXXXXXXXXXX
X
X
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XX
X X X X X X X X X X X X X X X X X X X XX
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
SHIFTED PROPERTY LINE
EXISTING PROPERTY LINE
XXXXXXXXXXX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X X X X X X X X X X X X X X X X X X X X X XX
X
X
X
X
X
REMOVE EXISTING RETAINING WALL
263 HYLAND AVE
GA
R
A
G
E
X
X
X
X
X
X
X
X
X
X
X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X X X X X X
X X X X X X X X X X X X
REMOVE EXISTING RETAINING WALL
DISCONNECT EXISTING
WATER SERVICE AT MAIN
(FIELD VERIFY DEPTH)
X
X
X
X
X
XX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
REMOVE EXISTING RETAINING WALL
FULL DEPTH PATCH, 100 SY
RE
M
O
V
E
E
X
I
S
T
I
N
G
G
A
R
A
G
E
REMOVE EXISTING APARTMENT BUILDING
FULL DEPTH PATCH, 30 SY
REMOVE 55 LF OF EXISTING CURB & GUTTER
REMOVE GAS SERVICE
S89°00'04"W 137.05
N0
°
5
8
'
4
3
"
W
7
4
.
5
0
N88°37'51"E 137.00
S0
°
5
9
'
5
6
"
E
7
4
.
5
0
S86°25'14"E 75.44
NOTE:
CONTRACTOR SHALL FIND EXISTING
SANITARY SEWER SERVICE FOR EACH
BUILDING AND ABANDON AT THE
BACK OF CURB.
SHEET
B
o
l
t
o
n
&
M
e
n
k
,
I
n
c
.
20
2
6
,
A
l
l
R
i
g
h
t
s
R
e
s
e
r
v
e
d
c H:
\
H
U
N
Z
I
\
2
4
X
1
3
5
5
0
5
0
0
0
\
C
A
D
\
C
3
D
\
1
3
5
5
0
5
C
1
0
1
.
d
w
g
8/
2
1
/
2
0
2
6
1
1
:
1
8
:
1
1
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HUNZIKER DEVELOPMENT
259/263 HYLAND
24X.135505.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100
Email: Ames@bolton-menk.com
www.bolton-menk.comR
C1.02
EXISTING CONDITIONS & REMOVALSFEETSCALE
0 10 20
HORZ.
R
LEGEND:
GRAVEL REMOVAL
PAVEMENT REMOVAL
SIDEWALK REMOVAL
ASPHALT/CONCRETE SAW CUT
15
LOT 2
0.47 ACRES
20,292 SQ FTLOT 1
0.27 ACRES
11,798 SQ FT
D
D
C
H H
C
S
S
S
S
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
>>
>>
>>
>>
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
>>>>>>
>>
>>
>>
>>
>>
>>
>>
>>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
>
>
>
>
>>>>
>
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
OE OE OE OE
OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE
F
F
F
F
F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
S
BUILDING A
FFE: 950.20
6,475 SF
BUILDING B
FFE: 932.50
6,955 SF
T
OA
K
L
A
N
D
S
T
HYLAND AVE
HYLAND AVE
EXISTING PROPERTY LINE
25
'
PROPOSED RETAINING WALL
20
.
5
3
'
PROPOSED PROPERTY LINE
12'
8'
7'
1'
20
'
25
'
15
.
5
'
15
'
11'
1'
20'
4'
5'
4'
5'
19
'
9'
108.5'
6.52'
25
'
34.5'
4'
12
2
.
7
9
'
PROPOSED RETAINING WALL
12
5
.
0
1
'
25
'
20
'
R2'
R5'
5'
15
.
2
6
'
25
'
ELECTRICAL TRANSFORMER
ELECTRICAL METERS
ELECTRICAL METERS
SETBACK LINE
SETBACK LINE
5'
PROPOSED RETAINING WALL
PROPOSED RETAINING WALL
9'
15.37'
20
'
26.03'
DUMPSTER ENCLOSURE
14' X 9.5'
SEE DETAIL
DUMPSTER ENCLOSURE
PEDESTRIAN ACCESS
PAVEMENT
MARKINGS
41
.
5
'
65
'
107'
64'
10
1
'
FIRE DEPARTMENT
CONNECTION
FIRE DEPARTMENT
CONNECTION
SIDEWALK
EASEMENT
4'
PROPOSED
BOLLARD
(TYP.)
SHEET
B
o
l
t
o
n
&
M
e
n
k
,
I
n
c
.
20
2
6
,
A
l
l
R
i
g
h
t
s
R
e
s
e
r
v
e
d
c H:
\
H
U
N
Z
I
\
2
4
X
1
3
5
5
0
5
0
0
0
\
C
A
D
\
C
3
D
\
1
3
5
5
0
5
C
2
0
1
.
d
w
g
8/
2
1
/
2
0
2
6
1
1
:
1
8
:
3
0
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HUNZIKER DEVELOPMENT
259/263 HYLAND
24X.135505.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100
Email: Ames@bolton-menk.com
www.bolton-menk.comR
C2.01
SITE GEOMETRICSFEETSCALE
0 10 20
HORZ.
R
16
LOT 2
0.47 ACRES
20,292 SQ FTLOT 1
0.27 ACRES
11,798 SQ FT
D
D
C
H H
C
S
S
S
S
M
M
M
M
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
G
G
G
G
G
G
>>
>>
>>
>>
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
>>>>>>
>>
>>
>>
>>
>>
>>
>>
>>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
>
>
>
>
>>>>
>
G
G
G
G
G
G
G
G
l
l
l
l
l
l
l
l
l
l
l
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
OE OE OE OE
OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE
F
F
F
G
G
G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G
F
F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
G G
S
l
l
l
l
l
l
l
l
l
l
l
930
93
5
94
0
94
5
95
0
95
5
927
928
929
931
932
93
3
93
4
93
6
93
7
93
8
93
9
94
1
94
2
94
3
94
4
94
6
94
7
94
8
94
9
95
1
95
2
95
3
95
4
95
6
93
0
93
5
92
8
92
9
93
1
93
293
393
4
93
693
7
938
945
95
0
955
941
942
943
944
946
94
7
94
8
94
9
951
95
2
95
3
954
95
6
955
95
195
2953954
956
947 945
944
946
935
940
945
950
955
936
937
938
939
941
942
943
944
946
947
948
949
951
952
953
954
956
96
0
95
7
95
8
95
9
96
1
93
5
94
0
93
293393
4936
93
6
93
6
93
7
93
8
93
9
94
1
94
1
941
94
2943
BUILDING A
FFE: 950.20
6,475 SF
BUILDING B
FFE: 932.50
6,955 SF
T
OA
K
L
A
N
D
S
T
HYLAND AVE
HYLAND AVE
SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF
SF SF
SF SF
SF
SF SF SF SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
5 TONS
RIP RAP2 TONS
RIP RAP
SHEET
B
o
l
t
o
n
&
M
e
n
k
,
I
n
c
.
20
2
6
,
A
l
l
R
i
g
h
t
s
R
e
s
e
r
v
e
d
c H:
\
H
U
N
Z
I
\
2
4
X
1
3
5
5
0
5
0
0
0
\
C
A
D
\
C
3
D
\
1
3
5
5
0
5
C
3
0
1
.
d
w
g
8/
2
1
/
2
0
2
6
1
1
:
1
8
:
5
4
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HUNZIKER DEVELOPMENT
259/263 HYLAND
24X.135505.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100
Email: Ames@bolton-menk.com
www.bolton-menk.comR
C3.01
EROSION CONTROL PLANFEETSCALE
0 10 20
HORZ.
R
LEGEND
SILT FENCE
INLET PROTECTION
CONCRETE WASHOUT
TYPE I SEEDING/SOD
LOW GROW GRASS
MIXTURE BY UNITED SEED
C
W
SF
17
LOT 2
0.47 ACRES
20,292 SQ FTLOT 1
0.27 ACRES
11,798 SQ FT
D
D
C
H H
C
S
S
S
S
M
M
M
M
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
G
G
G
G
G
G
>>
>>
>>
>>
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
>>>>>>
>>
>>
>>
>>
>>
>>
>>
>>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
>
>
>
>
>>>>
>
G
G
G
G
G
G
G
G
l
l
l
l
l
l
l
l
l
l
l
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
OE OE OE OE
OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE
F
F
F
G
G
G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G
F
F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
G G
S
l
l
l
l
l
l
l
l
l
l
l
930
93
5
94
0
94
5
95
0
95
5
927
928
929
931
932
93
3
93
4
93
6
93
7
93
8
93
9
94
1
94
2
94
3
94
4
94
6
94
7
94
8
94
9
95
1
95
2
95
3
95
4
95
6
93
0
93
5
92
8
92
9
93
1
93
293
393
4
93
693
7
938
945
95
0
955
942
943
944
946
94
7
94
8
94
9
95
1
95
2
95
3
954
95
6
95
0
955
95
195
2953954
956
947 945
944
946
935
940
945
950
955
936
937
938
939
941
942
943
944
946
947
948
949
951
952
953
954
956
96
0
95
7
95
8
95
9
96
1
93
5
94
0
932933934
93
6
937
93
8
93
9
94
1
94
1
941
942943
BUILDING A
FFE: 950.20
6,475 SF
BUILDING B
FFE: 932.50
6,955 SF
T
OA
K
L
A
N
D
S
T
HYLAND AVE
945946
947
94
0
937
938
939
94
1
94
2
94
3
93
0
92
792892
993
193
2
933
95
0
951
952
953
930
935
940
94
5
950
929
931
932
933
934
936937938939941942943
94
4
94
6
94
7
94
8
949951952953
945
941
942
943
944
TW
:
9
5
0
.
0
0
BW
:
9
4
2
.
0
0
TW
:
9
5
0
.
2
0
BW
:
9
4
2
.
0
0
TW
:
9
5
0
.
0
8
BW
:
9
4
9
.
8
2
TW
:
9
5
4
.
4
8
BW
:
9
5
7
.
9
8
TW
:
9
5
0
.
2
0
BW
:
9
3
9
.
6
1
TW
:
9
5
0
.
2
0
BW
:
9
4
6
.
0
0
TW
:
9
3
6
.
6
7
BW
:
9
3
4
.
1
2
TW
:
9
2
9
.
0
3
BW
:
9
2
8
.
8
4
TW
:
9
4
1
.
6
5
BW
:
9
3
2
.
8
4
TW
:
9
4
3
.
1
9
BW
:
9
3
2
.
6
8
TW
:
9
3
8
.
0
0
BW
:
9
3
3
.
9
1
TW
:
9
3
7
.
2
0
BW
:
9
3
3
.
7
5
TW
:
9
3
2
.
5
3
BW
:
9
3
2
.
0
1
TW
:
9
4
8
.
0
7
BW
:
9
4
7
.
4
2
950
.
0
4
950
.
1
2
FF:
9
3
2
.
5
0
FG:
9
2
8
.
8
2
TW
:
9
5
5
.
2
0
BW
:
9
5
0
.
2
5
TW
:
9
3
4
.
1
7
BW
:
9
3
2
.
8
6
TW
:
9
3
1
.
7
3
BW
:
9
3
1
.
6
4
TW
:
9
5
8
.
3
8
BW
:
9
5
2
.
9
6
4.55%
5.22%
FF:
9
5
0
.
2
0
FG:
9
5
3
.
7
8
EG
:
9
4
3
.
3
6
FG
:
9
3
9
.
8
2
EG:
9
4
1
.
3
8
FG:
9
3
3
.
2
5
EG:
9
3
7
.
2
6
FG:
9
3
2
.
4
6
EG:
9
4
7
.
1
4
FG:
9
4
1
.
3
0
EG:
9
4
2
.
1
1
FG:
9
3
3
.
5
7
EG:
9
3
8
.
1
0
FG:
9
3
2
.
7
1
EG:
9
5
1
.
5
5
FG:
9
4
2
.
2
9
EG:
9
5
0
.
7
8
FG:
9
4
2
.
4
4
EG:
9
4
2
.
9
4
FG:
9
4
2
.
9
6
EG:
9
5
1
.
9
7
FG:
9
4
3
.
7
8
EG:
9
4
7
.
2
3
FG:
9
4
3
.
5
5
EG:
9
4
3
.
7
1
FG:
9
4
3
.
7
9
EG:
9
5
2
.
2
0
FG:
9
4
5
.
4
4
EG
:
9
4
7
.
3
7
FG
:
9
4
5
.
1
9
EG:
9
4
3
.
8
6
FG:
9
4
4
.
9
5
NOTE:
BUILDING A AVERAGE HEIGHT: 41.25'
BUILDING B AVERAGE HEIGHT: 44.37'
SHEET
B
o
l
t
o
n
&
M
e
n
k
,
I
n
c
.
20
2
6
,
A
l
l
R
i
g
h
t
s
R
e
s
e
r
v
e
d
c H:
\
H
U
N
Z
I
\
2
4
X
1
3
5
5
0
5
0
0
0
\
C
A
D
\
C
3
D
\
1
3
5
5
0
5
C
4
0
1
.
d
w
g
8/
2
1
/
2
0
2
6
1
1
:
1
9
:
1
5
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HUNZIKER DEVELOPMENT
259/263 HYLAND
24X.135505.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100
Email: Ames@bolton-menk.com
www.bolton-menk.comR
C4.01
GRADING PLANFEETSCALE
0 10 20
HORZ.
R
18
LOT 2
0.47 ACRES
20,292 SQ FT
C
M
M
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
G G G
93
0
93
5
92
8
92
9
93
1
93
293
393
4
93
6
93
7
938
T
93
0
92
792892
993
193
2
933
930
929
928
.
7
0
928
.
4
2
927
.
9
7
927
.
9
2
928
.
8
2
932
.
6
5
93
1
.
3
0
932
.
3
1
932
.
3
3
932
.
3
0
932
.
6
3
932
.
5
0
932
.
5
0
932
.
5
0
TW
:
9
3
6
.
6
7
BW
:
9
3
4
.
1
2
TW
:
9
2
9
.
0
3
BW
:
9
2
8
.
8
4
TW
:
9
4
3
.
1
9
BW
:
9
3
2
.
6
8
926
.
8
6
926
.
7
8
926
.
4
9
926
.
9
1
927
.
1
9
927
.
2
7
0.82%4.80%4.80%
2.
0
1
%
2.
0
0
%
2.
0
0
%
2.
0
0
%
2.
0
8
%
2.
0
8
%
928
.
1
7
1.50%
1.50%
2.
0
4
%
2.
0
8
%
FF:
9
3
2
.
5
0
FG:
9
2
8
.
8
2
TW
:
9
3
4
.
1
7
BW
:
9
3
2
.
8
6
TW
:
9
3
1
.
7
3
BW
:
9
3
1
.
6
4
4.55%
5.22%
EG:
9
4
1
.
3
8
FG:
9
3
3
.
2
5
EG:
9
3
7
.
2
6
FG:
9
3
2
.
4
6
EG:
9
4
2
.
1
1
FG:
9
3
3
.
5
7
EG:
9
3
8
.
1
0
FG:
9
3
2
.
7
1
EG:
9
4
2
.
9
4
FG:
9
4
2
.
9
6
SHEET
B
o
l
t
o
n
&
M
e
n
k
,
I
n
c
.
20
2
6
,
A
l
l
R
i
g
h
t
s
R
e
s
e
r
v
e
d
c H:
\
H
U
N
Z
I
\
2
4
X
1
3
5
5
0
5
0
0
0
\
C
A
D
\
C
3
D
\
1
3
5
5
0
5
C
4
0
1
.
d
w
g
8/
2
1
/
2
0
2
6
1
1
:
1
9
:
1
7
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HUNZIKER DEVELOPMENT
259/263 HYLAND
24X.135505.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100
Email: Ames@bolton-menk.com
www.bolton-menk.comR
C4.02
GRADING PLANFEETSCALE
0 5 10
HORZ.
R
BUILDING B
FFE: 932.50
19
LOT 1
0.27 ACRES
11,798 SQ FT
D
C
D
GGGGGG
>>>>>>>>>>>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>>>>>>>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
G G G G G G G G
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
T
>>>>>>>>>>>>>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>>>>
>
>
>
>
>
>
>
>
>
>
>
>
>>>>
l l l l l l l l l l l l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l l l l l l l l l l l
l
l
l
l
l
l
l
l
l
l
l
l
l
l l l l l
l
l
l
l
l
l
l l l l l l l
>
>
l l l l l
l
l
l
l
l
l
l
l
l
l
l
l
l l l l l l l
>>>>>>>>
HY
L
A
N
D
A
V
E
CONNECT TO EXISTING 8" PVC
SANITARY SEWER
FL ELEV: 937.03
CONTRACTOR SHALL INSTALL 2' RISER
6" TAPPING VALVE & SLEEVE
6" TAPPING VALVE & SLEEVE
6" SANITARY SERVICE
6" FIRE SUPPRESSION
2" WATER SERVICE
6" WMN
6" WMN
6" SAN
6" FIRE SUPPRESSION
2" WATER SERVICE
EX
1
2
"
W
M
N
INSTALL 6"X2" TEE
2" CURBSTOP
6" FIRE VALVE
INSTALL 6"X2" TEE
2" CURBSTOP
6" FIRE VALVE
END SSWR
FL ELEV: 943.00
INSTALL 160 LF
OF SSWR @ 2%
INSTALL SANITARY CLEANOUT
RIM: 950.02
FL:938.17
INSTALL SANITARY CLEANOUT
RIM: 932.37
FL: 924.96
INSTALL 18 LF OF 12" STRM @ 2%
END STRM
FL ELEV: 938.19
END STRM
FL ELEV: 943.15
POTENTIAL SUBDRAIN
OUTLET LOCATION
IN
S
T
A
L
L
1
0
8
L
F
O
F
1
2
"
S
T
R
M
@
5
%
NOTE:
FULL DEPTH PATCH SHALL MATCH EXISTING
PAVEMENT THICKNESS OR 8", WHICHEVER IS
GREATER. FULL DEPTH PATCH SHALL INCLUDE
INSTALLATION OF 6" GRANULAR SUBBASE
AND SUBGRADE PREPARATION ON EXISTING
MATERIAL. INCLUDES ALL PAVEMENT
REMOVAL, SUBBASE REMOVAL, AND
SAWCUTTING.
SHEET
B
o
l
t
o
n
&
M
e
n
k
,
I
n
c
.
20
2
6
,
A
l
l
R
i
g
h
t
s
R
e
s
e
r
v
e
d
c H:
\
H
U
N
Z
I
\
2
4
X
1
3
5
5
0
5
0
0
0
\
C
A
D
\
C
3
D
\
1
3
5
5
0
5
C
5
0
1
.
d
w
g
8/
2
1
/
2
0
2
6
1
1
:
1
9
:
3
9
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HUNZIKER DEVELOPMENT
259/263 HYLAND
24X.135505.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100
Email: Ames@bolton-menk.com
www.bolton-menk.comR
C5.01
UTILITY PLANFEETSCALE
0 10 20
HORZ.
R
BUILDING A
FFE: 950.20
20
LOT 2
0.47 ACRES
20,292 SQ FT
D
C
H
H
C
S S
S
S
U
OEOE
OE OE OE OE OE OE OE OE OE OE OE
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>>>>>>>>>
>
>
>
>
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>>>>>>>>>>>>>>
>
>
G G G G G G G G
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
F
F
F
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
FFFFFF
F
F
FFFFFFFFFFFFFF
G
G
S
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
T
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>
>
>>>>
l
l
l l l l l l l l l l l
l
l
l
l
l
l
l
l
l
l
l
l
l
l l l l l
l
l
l
l
l
l
l l l l l l l
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
l
l l l l l l l
>>>>>>>>
>>>>
OAKLAND ST
HY
L
A
N
D
A
V
E
CONNECT TO EXISTING 8" PVC
SANITARY SEWER
FL ELEV: 911.87
CONTRACTOR SHALL INSTALL 10' RISER
6" TAPPING VALVE & SLEEVE
6" TAPPING VALVE & SLEEVE
6" WMN
6" WMN
6" SAN
6"
S
A
N
I
T
A
R
Y
S
E
R
V
I
C
E
6" FIRE SUPPRESSION
2" WATER SERVICE
EX
1
2
"
W
M
N
INSTALL 6"X2" TEE
2" CURBSTOP
6" FIRE VALVE
INSTALL 160 LF
OF SSWR @ 2%
INSTALL SANITARY CLEANOUT
RIM: 950.02
FL:938.17
INSTALL SANITARY CLEANOUT
RIM: 932.37
FL: 924.96
INSTALL SANITARY CLEANOUT
RIM: 929.04
FL: 923.48
END SSWR
FL ELEV: 925.00
INSTALL 144 LF OF
SSWR @ 2%
IN
S
T
A
L
L
5
4
L
F
O
F
1
2
"
S
T
R
M
@
5
%
INSTALL 18 LF OF 12" STRM @ 2%
END STRM
FL ELEV: 938.19
CONNECT TO EXISTING INTAKE
FL ELEV: 934.82SW - 301, 48"
RIM: 938.35
FL E: 934.92
FL SW: 935.02
POTENTIAL SUBDRAIN
OUTLET LOCATION
INSTALL 10 LF OF 12" STRM @ 1%
IN
S
T
A
L
L
1
0
8
L
F
O
F
1
2
"
S
T
R
M
@
5
%
NOTE:
FULL DEPTH PATCH SHALL MATCH EXISTING
PAVEMENT THICKNESS OR 8", WHICHEVER IS
GREATER. FULL DEPTH PATCH SHALL INCLUDE
INSTALLATION OF 6" GRANULAR SUBBASE
AND SUBGRADE PREPARATION ON EXISTING
MATERIAL. INCLUDES ALL PAVEMENT
REMOVAL, SUBBASE REMOVAL, AND
SAWCUTTING.
SHEET
B
o
l
t
o
n
&
M
e
n
k
,
I
n
c
.
20
2
6
,
A
l
l
R
i
g
h
t
s
R
e
s
e
r
v
e
d
c H:
\
H
U
N
Z
I
\
2
4
X
1
3
5
5
0
5
0
0
0
\
C
A
D
\
C
3
D
\
1
3
5
5
0
5
C
5
0
1
.
d
w
g
8/
2
1
/
2
0
2
6
1
1
:
1
9
:
4
0
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HUNZIKER DEVELOPMENT
259/263 HYLAND
24X.135505.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100
Email: Ames@bolton-menk.com
www.bolton-menk.comR
C5.02
UTILITY PLANFEETSCALE
0 10 20
HORZ.
R
BUILDING B
FFE: 932.50
21
M
G
G
G
G
G
G
G
G
G
G
G
G
G
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
>>>>>>>>>>>>>>>>>>>>>>
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
G
G
G
G
G
G G G G G G G G G G G G G G G G G G
F F F F F F F F F F F F F F F F F F F F F F F
950
.
2
0
950
.
1
5
950
.
1
3
950
.
2
0
950
.
1
3
950
.
2
0
950
.
2
0
950
.
1
2
950
.
1
2
950
.
2
0
949
.
5
5
949
.
6
2
949
.
2
0
950
.
8
9
950
.
8
0
950
.
9
6
953
.
7
6
953
.
2
7
953
.
2
0
953
.
6
8
954
.
0
1
953
.
8
7
3.37%
4.
3
3
%
5.
3
5
%
12.16%
1.
5
0
%
12.16%
1.
5
0
%
1.
0
0
%
0.30%
1.
5
1
%
1.
5
0
%
1.
5
0
%
1.
5
0
%
4.
3
8
%
1.
5
0
%
6.
5
6
%
7.
3
4
%
0.02%
6.62%
1.
5
0
%
1.
0
7
%
6.02%
950
.
1
2
950
.
2
0
950
.
9
0
950
.
8
5
0.
9
4
%
0.87%
6.
8
8
%
1.56%
0.29%
1.50%
1.
5
0
%
1.50%
1.
5
0
%
4.
5
0
%
4.
0
4
%
95
3
.
6
2
953.56
953.50
95
3
.
5
6 C
M
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
>>>>>>>>>>>>>>>>>>>>>>
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G G G G G G G G G G G G G G G G G G G G G G G G
F F F F F F F F F F F F F F F F F F F F F F F
HYLAND AVE
950
.
1
2
950
.
1
2
950
.
2
0
944.19 944
.
2
5
944
.
1
9
944
.
2
5
944
.
0
9
944
.
2
3
945
.
7
6
945
.
8
2
945
.
8
9
945
.
6
8
1.
5
0
%
1.50%
1.50%
0.
2
5
%
1.88%
7.
9
2
%
1.
4
0
%
5.07%
1.
5
0
%
1.50%
7.
9
7
%
SHEET
B
o
l
t
o
n
&
M
e
n
k
,
I
n
c
.
20
2
6
,
A
l
l
R
i
g
h
t
s
R
e
s
e
r
v
e
d
c H:
\
H
U
N
Z
I
\
2
4
X
1
3
5
5
0
5
0
0
0
\
C
A
D
\
C
3
D
\
1
3
5
5
0
5
C
6
0
1
.
d
w
g
8/
2
1
/
2
0
2
6
1
1
:
1
9
:
4
4
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HUNZIKER DEVELOPMENT
259/263 HYLAND
24X.135505.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100
Email: Ames@bolton-menk.com
www.bolton-menk.comR
C6.01
SIDEWALK ADAFEETSCALE
0 5 10
HORZ.
R
R
22
LOT 2
0.47 ACRES
20,292 SQ FT
D H H S
S
M
OE
OE
OE
OE
OE
OE
>>>>>>>>>>>>>>>>>>>>
>>
>>
>>
>>
>>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>>>>
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
F
G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G
F FFFFFFFFFFFFFFFFFFFFFFFFFFFF
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
OA
K
L
A
N
D
S
T
HYLAND AVE
932
.
5
0
932
.
5
0
932
.
4
2
932
.
4
2
932
.
3
6
932
.
2
8
932
.
2
1
932
.
2
8
932
.
5
0
932
.
4
2
932
.
3
9
932
.
5
0
931
.
9
0
931
.
9
8
931
.
9
0
931
.
8
3
932
.
7
1
932
.
8
1
933
.
8
8
933
.
9
0
1.
5
0
%
0.39%
2.
1
4
%
1.
5
2
%
1.50%
1.
5
0
%
1.50%
2.21%
1.36%1.50%
1.
5
0
%
1.50%
1.
5
0
%
2.63%
0.
4
9
%
1.50%
1.50%
1.
0
0
%
1.10%
SHEET
B
o
l
t
o
n
&
M
e
n
k
,
I
n
c
.
20
2
6
,
A
l
l
R
i
g
h
t
s
R
e
s
e
r
v
e
d
c H:
\
H
U
N
Z
I
\
2
4
X
1
3
5
5
0
5
0
0
0
\
C
A
D
\
C
3
D
\
1
3
5
5
0
5
C
6
0
1
.
d
w
g
8/
2
1
/
2
0
2
6
1
1
:
1
9
:
4
6
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HUNZIKER DEVELOPMENT
259/263 HYLAND
24X.135505.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100
Email: Ames@bolton-menk.com
www.bolton-menk.comR
C6.02
SIDEWALK ADAFEETSCALE
0 5 10
HORZ.
R
23
LOT 2
0.47 ACRES
20,292 SQ FTLOT 1
0.27 ACRES
11,798 SQ FT
D
D
C
H H
C
M
M
M
M
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
G
G
G
G
G
G
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
>>>>>>
>>
>>
>>
>>
>>
G
G
G
G
G
G
G
G
l
l
l
E
E
E
E
E
OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE
F
F
F
G
G
G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G
F
F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
G
l
l
l
l
l
l
BUILDING A
FFE: 950.20
6,475 SF
BUILDING B
FFE: 932.50
6,955 SF
T
RETAINING WALL AND
FENCE TO EQUAL 6'
TOTAL HEIGHT.
RETAINING
WALL
RETAINING
WALL
RETAINING
WALL
RETAINING
WALL
SPADE CUT
EDGE, TYP.
(1) AG
(1) GT (1) GT (1) QB
(1) AP(1) AP
(3) TO
(3) SH
(12) PD
(3) SS
(2) SH (3) SH(1) JP
(5) SP
(12) CK (8) SH
(3) SP
(3) SS
(8) SH
(3) SP
(4) PD
(1) VL
(1) SP (1) FN
(3) SH
(3) SH
(3) SH
(8) JP
(3) UJ
(27) CK
(3) MP
(3) SM (2) SM
(5) SM
CODE QTY DETAIL BOTANICAL NAME COMMON NAME CALIPER HEIGHT CONTAINER
CANOPY TREES
GT 4 GLEDITSIA TRIACANTHOS INERMIS 'SKYCOLE'SKYLINE® HONEY LOCUST 2" CAL.40-65' MAT. HT.B&B
QB 1 QUERCUS BICOLOR SWAMP WHITE OAK 2" CAL.55-65' MAT.HT.B&B
UJ 3 ULMUS AMERICANA 'JEFFERSON'JEFFERSON AMERICAN ELM 2" CAL.40-65' MAT. HT.B&B
ORNAMENTAL TREES
AP 2 ACER PLATANOIDES X TRUNCATUM 'PACIFIC SUNSET'PACIFIC SUNSET MAPLE 1.5" CAL.35' MAT.HT.B&B
AG 1 AMELANCHIER X GRANDIFLORA 'AUTUMN BRILLIANCE'AUTUMN BRILLIANCE APPLE SERVICEBERRY 1.5" CAL.20' MAT.HT.B&B
MP 3 MALUS X 'PRAIRIFIRE'PRAIRIFIRE CRABAPPLE 1.5" CAL.20' MAT.HT.B&B
PLANT SCHEDULE
MALUS X 'PRAIRIFIRE'PRAIRIFIRE CRABAPPLE 20' MAT.HT.
CODE QTY BOTANICAL NAME COMMON NAME SPREAD HEIGHT CONTAINER
SHRUBSFN1 FORSYTHIA X 'NORTHERN GOLD'NORTHERN GOLD FORSYTHIA N.A.6 - 8` HT.#5 CONT.
JP 9 JUNIPERUS X PFITZERIANA 'SEA GREEN'SEA GREEN PFITZER JUNIPER N.A.4 - 6` HT.#5 CONT.
PD 17 PHYSOCARPUS OPULIFOLIUS 'DONNA MAY'LITTLE DEVIL™ DWARF NINEBARK N.A.3 - 4` HT.#3 CONT.
SM 10 SPIRAEA MEDIA 'SMSMBK'BLUE KAZOO® DOUBLE PLAY® SPIREA N.A.2 - 3' HT.#5 CONT.
SP 9 SYRINGA PUBESCENS PATULA 'MISS KIM'MISS KIM KOREAN LILAC N.A.6 - 8` HT.#5 CONT.
TO 4 THUJA OCCIDENTALIS 'HOLMSTRUP'HOLMSTRUP ARBORVITAE N.A.5 - 7` HT.#5 CONT.
VL 1 VIBURNUM LENTAGO NANNYBERRY VIBURNUM N.A.12 - 14` HT.#5 CONT.
PERENNIALSCK49 CALAMAGROSTIS X ACUTIFLORA 'KARL FOERSTER'KARL FOERSTER GRASS N.A.4 - 6` HT.#1 CONT.
SS 6 SCHIZACHYRIUM SCOPARIUM 'CAROUSEL'CAROUSEL LITTLE BLUESTEM N.A.2 - 3' HT.#1 CONT.
SH 50 SPOROBOLUS HETEROLEPIS PRAIRIE DROPSEED N.A.2 - 3' HT.#1 CONT.
SHEET
B
o
l
t
o
n
&
M
e
n
k
,
I
n
c
.
20
2
6
,
A
l
l
R
i
g
h
t
s
R
e
s
e
r
v
e
d
c H:
\
H
U
N
Z
I
\
2
4
X
1
3
5
5
0
5
0
0
0
\
C
A
D
\
C
3
D
\
1
3
5
5
0
5
C
7
0
1
.
d
w
g
8/
2
1
/
2
0
2
6
1
1
:
2
0
:
0
7
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HUNZIKER DEVELOPMENT
259/263 HYLAND
24X.135505.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100
Email: Ames@bolton-menk.com
www.bolton-menk.comR
C7.01
LANDSCAPING PLANFEETSCALE
0 10 20
HORZ.
R
GENERAL NOTES: LANDSCAPE PLANTING
1.MASTER PLANT SCHEDULE: ALL TREES, SHRUBS, AND ORNAMENTAL GRASSES
ARE LISTED IN THE MASTER PLANT SCHEDULE. IF THERE IS A CONFLICT
BETWEEN THE QUANTITIES SHOWN ON THE DRAWINGS AND THE QUANTITIES
SHOWN IN THE PLANT SCHEDULE, THE PLAN QUANTITIES SHALL PREVAIL.
2.PLANTING LAYOUT: STAKE ALL TREE LOCATIONS AND A TYPICAL
SHRUB/ORNAMENTAL GRASS BED LAYOUT AND OBTAIN APPROVAL OF THE
OWNER'S REPRESENTATIVE PRIOR TO PLANTING.
3.SHRUB/ORNAMENTAL GRASS GROUPINGS SHALL BE PLANTED AND MULCHED
IN ONE CONTINUOUSLY MULCHED BED. ALL OVERSTORY TREES SHALL BE
MULCHED TO 18 INCHES FROM TRUNK (3' DIA. RING) IN ALL DIRECTIONS AND
TO A DEPTH OF 3" UNLESS OTHERWISE NOTED.
4.CONTRACTOR TO PROVIDE AMENDED SOIL MIX FOR INCORPORATION INTO
BACKFILL OF ALL ORNAMENTAL GRASS, SHRUB AND TREE AREAS, AND ALL
AREAS LABELED "LANDSCAPE AREA". THIS AMENDED SOIL MIX SHALL
CONSIST OF 5% ORGANIC MATTER INCORPORATED INTO THE TOP 8 INCHES
OF PLANTING AREAS AROUND ALL ORNAMENTAL GRASSES, SHRUBS AND
TREES. AMENDED SOIL MIX SHOULD INCORPORATE SOIL FROM THE SITE AS
WELL AS AN ORGANIC COMPOST, BUT MAY ALSO USE EXISTING SOIL IF
ORGANIC CONTENT MEETS THE 5% MINIMUM REQUIREMENT. CONTRACTOR
TO PROVIDE CERTIFICATION OF ORGANIC MATTER CONTENT OF EXISTING
SOIL AND/OR COMPOST AND EXISTING SOIL BLEND PRIOR TO
INCORPORATING MATERIAL AROUND ORNAMENTAL GRASSES, SHRUBS AND
TREES.
5.PREPARING SPADE-CUT EDGE AND PLACING AMENDED SOIL AND SHREDDED
HARDWOOD MULCH SHALL BE INCIDENTAL TO THE PLANTING BID ITEMS AND
SHALL BE INSTALLED AS PER SPECIFICATIONS. ALL MULCH SHALL BE
SHREDDED HARDWOOD MULCH.
6.ALL AREAS NOT CALLED OUT AS PLANTING BEDS TO RECEIVE SUDAS TYPE 1
PERMANENT LAWN SEEDING WITH HYDROMULCH COVER, UNLESS
OTHERWISE SPECIFIED ON EROSION CONTROL PLAN. SEEDING, FERTILIZING
AND STABILIZATION TO BE PERFORMED PER SUDAS SPECIFICATIONS.
LANDSCAPE AREA (TYP.) SEE
GENERAL PLANTING NOTES
LANDSCAPE REQUIREMENTS:
RESIDENTIAL
FRONT YARD LANDSCAPE (372 LF):
1 / 50 LF FOR OVERSTORY TREES, 12 / 50 LF FOR SHRUBS
(3:1 ORNAMENTAL GRASS REPLACEMENT RATIO)
REQUIRED TREES: (372 LF/50) = 8
PROVIDED: 8 OVERSTORY TREES
REQUIRED SHRUBS & GRASSES:
REQUIRED SHRUBS BTWN STREET AND PARKING LOT: 27 / 50 = 1 * 12 = 12
PROVIDED: 12 SHRUBS
REQUIRED SHRUBS IN OTHER FRONT YARD AREAS: 345 / 50 = 6.9 * 9 = 63
PROVIDED: 38 SHRUBS (25 SHRUBS ACCOUNTED FOR BY 75 GRASSES AT 3:1 RATIO)
LANDSCAPE AREA AT PARKING (4,900 SF):
REQUIRED: (4,900 SF*0.1) = 490 SF
PROVIDED: 546 SF
PARKING OVERSTORY TREES:
REQUIRED TREES: (546 SF / 200) = 2.73, RND TO (3)
PROVIDED: 3 UNDERSTORY TREES PER CITY COMMENT
PARKING SCREEN (122 LF):
NORTH PARKING LOT IS SCREENED BY 6' HEIGHT RETAINING WALL
REQUIRED PER CITY COMMENT: 3 GRASSES PER 20 LF = 122/ 20 = 6.1*3 = RND TO (19)
PROVIDED: 27 ORNAMENTAL GRASSES
HIGH SCREEN DISSIMILAR USE (117 LF):
TWO UNDERSTORY TREES ALONG SOUTH AND 1 UNDERSTORY TREE ALONG NORTH,
HIGH SCREEN DISSIMILAR USE NOT REQUIRED PER CITY COMMENT.
REQUIRED TREES: (117 LF/50) = 2.34, RND TO (3)
PROVIDED: 3 UNDERSTORY TREES (DUE TO O.H. ELECTRICAL LINES)
24
NOTES:
1.O.C. TRIANGULAR PLANT SPACING PER PLANS
2.AREAS IDENTIFIED ON PLANTING PLAN AS O.C.
SHALL BE TRIANGULAR SPACED
3.SEE PLANTING PLAN/SCHEDULE FOR SPECIES
1 PERENNIAL PLANT SPACING
SCALE: N.T.S.
AMENDED PLANTING SOIL, AS SPECIFIED
3" DEPTH MULCH AS SPECIFIED,
KEEP MULCH CLEAR OF PLANT STEM AS SHOWN
18
"
2x ROOT BALL DIAMETER
O.C. SPACING PER PLANS
2 PERENNIAL / SHRUB PLANTING
SCALE: N.T.S.
NOTES:
SPADE-CUT EDGE TO BE INCIDENTAL TO PLANT
MATERIAL AND SHALL BE USED WHERE ALL LANDSCAPE
BEDS MEET ADJACENT SEEDED OR LAWN AREAS.
SHRUB/PERENNIAL BED
HARDWOOD MULCH
6"
6"
LAWN
SPADE-CUT EDGE
FILLED WITH MULCH
3 SECTION: SPADE-CUT EDGE
SCALE: N.T.S.
1'-0"
DEPTH AS SPECIFIED
HARDWOOD MULCH
3" DEPTH
AMENDED SOIL,
AS SPECIFIED
HAND DUG TRENCH
AT WALK EDGE
3"
4 PLANTING EDGE AT HARDSCAPE SURFACE
SCALE: N.T.S.
AMENDED PLANTING SOIL BACKFILL
REMOVE TOP 1/3 OF WIRE BASKET
AFTER TREE IS IN THE PIT.
REMOVE TWINE, & PULL BURLAP
FROM TREE TRUNK
NOTE: SET TOP OF ROOT BALL
1" TO 2" ABOVE SURROUNDING
FINISH GRADE
NYLON STRAP GUY ASSEMBLY
STEEL POST NOTCHED OR
DRILLED FOR GUY WIRE.
DO NOT CUT LEADER
USE 3 GUY ASSEMBLIES FOR
EVERGREENS
4" TREE WRAP ON
DECIDUOUS TREES
3" MULCH DEPTH, PULL BACK
4" FROM TREE TRUNK
4'
-
0
"
PO
S
T
H
E
I
G
H
T
3'
-
0
"
GU
Y
H
E
I
G
H
T
ROOT FLARE OF TREE
FINISH GRADE
MIN. 2X ROOT BALL DIA.
5 TREE PLANTING
SCALE: N.T.S.
SOIL RIDGE TO HOLD
WATER IN BASIN.
SOIL BACKFILL PER SPECIFICATIONS
EXISTING GRADE
ON 2:1 SLOPES OR GREATER, DO NOT CONSTRUCT
THE UPHILL HALF OF THE WATERING BASIN.
6 TREE PLANTING ON SLOPES
SCALE: N.T.S
SHEET
B
o
l
t
o
n
&
M
e
n
k
,
I
n
c
.
20
2
6
,
A
l
l
R
i
g
h
t
s
R
e
s
e
r
v
e
d
c H:
\
H
U
N
Z
I
\
2
4
X
1
3
5
5
0
5
0
0
0
\
C
A
D
\
C
3
D
\
1
3
5
5
0
5
C
7
0
1
.
d
w
g
8/
2
1
/
2
0
2
6
1
1
:
2
0
:
0
8
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HUNZIKER DEVELOPMENT
259/263 HYLAND
24X.135505.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100
Email: Ames@bolton-menk.com
www.bolton-menk.comR
C7.02
LANDSCAPING DETAILS 25
LOT 2
0.47 ACRES
20,292 SQ FTLOT 1
0.27 ACRES
11,798 SQ FT
D
D
C
H H
C
S
S
S
S
M
M
M
M
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
G
G
G
G
G
G
>>
>>
>>
>>
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
>>>>>>
>>
>>
>>
>>
>>
>>
>>
>>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
>
>
>
>
>>>>
>
G
G
G
G
G
G
G
G
l
l
l
l
l
l
l
l
l
l
l
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
OE OE OE OE
OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE
F
F
F
G
G
G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G
F
F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
G G
S
l
l
l
l
l
l
l
l
l
l
l
BUILDING A
FFE: 950.20
6,475 SF
BUILDING B
FFE: 932.50
6,955 SF
T
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
>
>>>>>>>>>>
>
>
>
>
>
>
>
>
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
>>
>>
>>
>>
>>
>>
OA
K
L
A
N
D
S
T
HYLAND AVE
HYLAND AVE
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXX X X XX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXXXXX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
PHASE 1 WALL REMOVAL
PHASE 2 WALL REMOVAL
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
GRADE TEMPORARY
DRAINAGE SWALE
SHEET
B
o
l
t
o
n
&
M
e
n
k
,
I
n
c
.
20
2
6
,
A
l
l
R
i
g
h
t
s
R
e
s
e
r
v
e
d
c H:
\
H
U
N
Z
I
\
2
4
X
1
3
5
5
0
5
0
0
0
\
C
A
D
\
C
3
D
\
1
3
5
5
0
5
C
8
0
1
.
d
w
g
8/
2
1
/
2
0
2
6
1
1
:
2
0
:
3
0
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HUNZIKER DEVELOPMENT
259/263 HYLAND
24X.135505.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100
Email: Ames@bolton-menk.com
www.bolton-menk.comR
C8.01
PHASING PLANFEETSCALE
0 10 20
HORZ.
R
LEGEND
PHASE 1
PHASE 2
26
OAKLAND ST
SHEL
D
O
N
A
V
E
HY
L
A
N
D
A
V
E
WEST ST
SH
E
L
D
O
N
A
V
E
CA
M
P
U
S
A
V
E
WO
O
D
L
A
N
D
S
T
WEST ST
HY
L
A
N
D
A
V
E
UNION DR
1
2
2
1
SHEET
B
o
l
t
o
n
&
M
e
n
k
,
I
n
c
.
20
2
6
,
A
l
l
R
i
g
h
t
s
R
e
s
e
r
v
e
d
c H:
\
H
U
N
Z
I
\
2
4
X
1
3
5
5
0
5
0
0
0
\
C
A
D
\
C
3
D
\
1
3
5
5
0
5
C
9
0
1
.
d
w
g
8/
2
1
/
2
0
2
6
1
1
:
2
1
:
2
0
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV HUNZIKER DEVELOPMENT
259/263 HYLAND
24X.135505.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100
Email: Ames@bolton-menk.com
www.bolton-menk.comR
C9.01
TRAFFIC CONTROL PLANFEETSCALE
0 10 20
HORZ.
AHEAD
CLOSED
ROAD
W20-3
(48 X 48)
SIGN 1
AHEAD
DETOUR
W20-2
(48 X 48)
SIGN 2
LEGEND
TRAFFIC SIGN
TYPE III BARRICADE
WORK AREA
ROAD CLOSURE
M4-10L
(48x18)
DETOUR
ROADTOTRAFFICTHRU
CLOSED
R11-4
(60 X 30)
M4
-
9
R
(3
0
X
2
4
)
DE
T
O
U
R
HY
L
A
N
D
A
V
E
M4-9L
(30 X 24)
DETOUR
HYLAND AVE
M4-9R
(30 X 24)
DETOUR
HYLAND AVE
M4
-
9
L
(3
0
X
2
4
)
DE
T
O
U
R
HY
L
A
N
D
A
V
E
M4-9L
(30 X 24)
DETOUR
HYLAND AVE M4
-
9
R
(3
0
X
2
4
)
DE
T
O
U
R
HY
L
A
N
D
A
V
E
M4-
9
R
(30
X
2
4
)
DET
O
U
R
HYL
A
N
D
A
V
E
ROADTOTRAFFICTHRU
CLOSED
R11-4
(60 X 30)
DETOUR
M4-10R
(48 X 18)
CLOSED
ROAD
R11-2
(48 X 30)
CLOSED
ROAD
R11-2
(48 X 30)
END
DETOUR
M4-8A
(24 X 18)
END
DETOUR
M4-8A
(24 X 18)
R
PROJECT LOCATION
27
S. BLDG. LV 1
0"
S. BLDG. LV 2
11'-6"
S. BLDG. LV 3
23'-0"
S. BLDG. ROOF
34'-6"
101'-0"
S. BLDG. LV 1
0"
S. BLDG. LV 2
11'-6"
S. BLDG. LV 3
23'-0"
S. BLDG. ROOF
34'-6"
101'-1"
S. BLDG. LV 1
0"
S. BLDG. LV 2
11'-6"
S. BLDG. LV 3
23'-0"
S. BLDG. ROOF
34'-6"
TYP
6'-0"
TY
P
6'
-
0
"
TYP
3'-0"
64'.
S. BLDG. LV 1
0"
S. BLDG. LV 2
11'-6"
S. BLDG. LV 3
23'-0"
S. BLDG. ROOF
34'-6"
PARAPET
37'-6"
1
SD ELEVS S BLDG
05/29/26
Re
s
i
d
e
n
t
i
a
l
D
e
v
e
l
o
p
m
e
n
t
Da
y
t
o
n
P
a
r
k
L
L
C
25
9
/
2
6
3
H
y
l
a
n
d
A
v
e
,
A
m
e
s
,
I
o
w
a
SCALE:1/16" = 1'-0"4 SOUTH ELEVATION
SCALE:1/16" = 1'-0"2 NORTH ELEVATION
SCALE:1/16" = 1'-0"3 WEST ELEVATION
SCALE:1/16" = 1'-0"1 EAST ELEVATION
THIN BRICK (68% OF FACADE EXCLUDING WINDOWS)
HARDIE ARCHITECTURAL PANEL
HARDIE ARTISAN
28
N. BLDG. LV 1
-17'-6"
N. BLDG. LV 2
-6'-0"
N. BLDG. LV 3
5'-6"
N. BLDG. LV 4
17'-0"
N. BLDG. ROOF
28'-6"
107'-2"
N. BLDG. LV 1
-17'-6"
N. BLDG. LV 2
-6'-0"
N. BLDG. LV 3
5'-6"
N. BLDG. LV 4
17'-0"
N. BLDG. ROOF
28'-6"
65'-0"
THIN BRICK 60%
N. BLDG. LV 1
-17'-6"
N. BLDG. LV 2
-6'-0"
N. BLDG. LV 3
5'-6"
N. BLDG. LV 4
17'-0"
N. BLDG. ROOF
28'-6"
107'-2"
N. BLDG. LV 1
-17'-6"
N. BLDG. LV 2
-6'-0"
N. BLDG. LV 3
5'-6"
N. BLDG. LV 4
17'-0"
N. BLDG. ROOF
28'-6"
65'-0"
2
SD ELEVS N BLDG
05/19/26
Re
s
i
d
e
n
t
i
a
l
D
e
v
e
l
o
p
m
e
n
t
Da
y
t
o
n
P
a
r
k
L
L
C
25
9
/
2
6
3
H
y
l
a
n
d
A
v
e
,
A
m
e
s
,
I
o
w
a
SCALE:1/16" = 1'-0"1 EAST ELEVATION
SCALE:1/16" = 1'-0"2 NORTH ELEVATION
SCALE:1/16" = 1'-0"3 WEST ELEVATION
SCALE:1/16" = 1'-0"4 SOUTH ELEVATION
THIN BRICK 64%
29
ME
C
H
/
SP
R
I
N
K
AD
A
TRASH
8'-1"
18
'
-
6
"
8'
-
0
"
5'-4"11'-0"9'-0"1'-6"9'-0"9'-0"9'-0"37'-6"9'-1"
19
'
-
0
"
24
'
-
0
"
19
'
-
0
"
9'
-
1
1
"
8'-9"8'-11"8'-0"8'-0"9'-0"1'-6"9'-0"9'-0"9'-0"1'-6"9'-0"9'-0"
8'-6"8'-6"
101'-2"
64
'
.
37'-8"24'-11"37'-8"
19
'
-
1
"
9'
-
6
"
5'
-
6
"
28
'
-
7
"
0
'
16'4'8'
Project StatusResidential Development
259 / 263 Hyland Ave, Ames, Iowa
Dayton Park LLC
SCALE:1/8" = 1'-0"1 SOUTH BUILDING LEVEL 1
SOUTH BUILDING
• THREE STORIES
• 13 UNITS
• 3 STUDIO
• 4 ONE-BED
• 6 TWO-BED
• 13 INTERIOR PARKING STALLS
SCALE:1/8" = 1'-0"2 SOUTH BUILDING LEVELS 2 & 3
30
MECH/SPRINK
ADA
1'-1"19'-0"25'-0"10"18'-2"1'-1"
3'
-
6
"
18
'
-
0
"
3'
-
6
"
9'
-
0
"
9'
-
0
"
9'
-
0
"
1'
-
6
"
9'
-
0
"
9'
-
0
"
9'
-
0
"
1'
-
6
"
9'
-
0
"
9'
-
0
"
5'
-
0
"
7'
-
8
"
18'-4"
59
'
-
0
"
5'
-
0
"
11
'
-
0
"
1'
-
6
"
9'
-
0
"
9'
-
4
"
10
'
-
2
"
13
'
-
7
"
12
'
-
1
0
"
13
'
-
6
"
13
'
-
9
"
12
'
-
7
"
13
'
-
6
"
12
'
-
1
0
"
13
'
-
7
"
10
7
'
-
0
"
65'-0"
28'-5"7"5'-5"7"28'-0"
10
'
-
4
"
24
'
-
0
"
24
'
-
0
"
37
'
-
3
"
10
'
-
5
"
0
'
16'4'8'
Project StatusResidential Development
259 / 263 Hyland Ave, Ames, Iowa
Dayton Park LLC
NORTH BUILDING
• FOUR STORIES
• 19 UNITS
• 10 ONE-BED
• 9 TWO-BED
• 10 INTERIOR PARKING STALLS
• 11 EXTERIOR PARKING STALLS
SCALE:1/8" = 1'-0"1 NORTH BUILDING LEVEL 1
SCALE:1/8" = 1'-0"2 NORTH BUILDING LEVELS 2-4
31
32
1
ADDENDUM
The project is a rezoning with a Major Site Development Plan to ensure consistency with
the purpose of the requested O-WUPED. The rezoning request conformity to the
Comprehensive Plan is guided by the Major Site Development Plan details.
To approve the rezoning, the application must be found to conform to:
Sec. 29.1115. "O-WUPED" West University Pedestrian Enhancement District
(1) Purpose. The intent of O-WUPED is to implement the Comprehensive Plan
Residential Neighborhood 4 (RN-4) (Walkable Urban) Land Use Designation by
encouraging new multi-family or mixed-use development with an enhanced relationship
between buildings, the pedestrian environment, and the character of the area as a distinct
place.
(2) Establishment. O-WUPED applies to all lands that have a base zoning district of
Residential High Density (RH) and are zoned O-WUPED on the Zoning Map. O-WUPED
replaces the O-UIW West University Impacted District upon approval. A Zoning Map
Amendment may be approved provided the City Council makes the following findings:
a. The designation is consistent with the Comprehensive Plan and has a future land use
designation of RN-4 or, subject to review of commercial opportunities as mixed use, is
within the Neighborhood Commercial Mixed Use sub-designation of RN-4.
b. The property has a residential zoning of RH or is concurrently proposed to be changed
to RH.
c. The property is located along and/or between Sheldon Avenue or Hyland Avenues,
north of Lincoln Way and south of Oakland.
d. The proposed development is a new construction apartment dwelling or mixed-use
development. O-WUPED shall not apply to development that involves conversions of or
additions to existing structures or to single- and two-family dwellings.
e. The existing and proposed infrastructure for the development is sufficient in design and
capacity to support the project with water, sanitary sewer, storm drainage, streets and
other transportation related facilities including pedestrian facilities.
f. A Major Site Development Plan (MSDP), consistent with Sec. 29.1502, is submitted
concurrently with the petition for rezoning. The MSDP must demonstrate consistency with
all requirements and standards of the Overlay.
PROJECT DESCRIPTION:
The applicants request a rezoning of the property and approval of a Major Site
Development Plan for 259 and 263 Hyland Avenue. The proposal is for two apartment
buildings and a total of 32 units with 47 total bedrooms. The proposal will require approval
of a Plat of Survey to alter the existing property lines and allow both properties to meet
setback requirements.
33
2
SURROUNDING AREA:
Surround land to the north, south, and east is zoned RH. Property to the west is zoned
RL.
The RL land immediately abutting the site is developed as single-family detached homes
on standard lots. There are four homes that immediately abut the subject property.
Along Hyland and Sheldon Ave to the east, the properties are zoned RH and developed
as higher density apartment buildings. Property located east of the Hyland, Oakland, and
Sheldon intersection is zoned S-GA and used for the Iowa State University Campus.
Existing Zoning
The properties currently have a base zone of RH. This Zone is intended to accommodate
high-density residential areas in the City, including areas on or adjacent to the Iowa State
University campus and areas adjacent to existing commercial and employment centers.
The properties are located west of ISU campus and contain existing multi -family
development.
The property also contains the existing overlay of “O-UIW” (West University Impacted
District). The O-UIW was established in 2006 with the purpose to include areas adjacent
to the Iowa State University campus and affiliated facilities, in order to inc rease housing
diversity opportunities and housing density, to the extent that base zoning would allow,
while assuring adequate parking and architectural compatibility with the characteristics of
existing structures, such as location, height, materials and the appearance of façades
facing streets, by creating regulatory standards for commercial and high density
residential uses, but not impacting single or two family uses.
AMES PLAN 2040:
Comprehensive Plan (Ames Plan 2040). The Ames Plan 2040 Comprehensive Plan
designation of the subject area is Residential Neighborhood 4 (RN-4 Walkable Urban
Neighborhood)(See attached excerpt). The proposed change of the overlay zone to O-
WUPED is consistent with that designation. O-WUPED was recently established to better
align the current goals of the Comprehensive Plan, which was not established in 2006
when O-UIW was created. The O-WUPED was also established to align with the RN-4
designations, which emphasizes walkability, pedestrian oriented design, higher density,
and mixed-use development. See the RN-4 Excerpt for complete details.
The proposed rezoning consistent with the Ames Plan 2040 Comprehensive Plan.
There are several goals in Ames Plan 2040 that can support the proposed rezoning.
Goals:
- G3. Ames will take advantage of existing infill sites within the existing urbanized
area to increase both the efficiency and quality of its urban environment. Infill
development may change the types and intensities of land use and introduce new
34
3
building forms. Larger areas planned for change are described as redirection or
redevelopment areas. As such, it requires an assessment of community needs
and character of the surrounding area to guide planning and policy decisions on
specific changes.
- G3-2. Coordinate infill development with the capacity of existing infrastructure.
- G3-3. Use prevailing density as the guide for redevelopment but allow for building
variations to meet infill objectives. Make smooth transudations in scale and
intensity of use from pre-existing context to higher intensity development. Support
high-density redevelopment only in planned or targeted land use redirections
areas.
- G3-4. Establish design standards and guidelines for individual infill sites that are
compatible with the scale of surrounding neighborhoods or other urban design
factors. In specific areas, planned increases in intensity of use will determine
increased height and an urban form, but still include architectural design quality
- G5-2. Apply guidelines and processes in advance that increase the level of
predictability to all parties in the development process.
259 Hyland Building A- Discussion
Summary Table Major Standards for Building A. Items with a * discussed below.
Standard (allows
20% variation)
Proposed Principle/Supplemental Standard
Front
Setback*
25 Feet
15 Feet to
Façade, 25 feet to
garage entrance
Front setback reduction
Supplemental Standard to 15 feet:
“15 feet for buildings with first floor
residential units facing the street.”
Side Setback 10 feet (3-stories) 14 and 11 feet None
Height 45 feet 41.25 feet None
Rear
Setback*
25 Feet 20.5 feet None
Primary
Façade Max.
Setback
25 feet 15 feet None
Materials 60% brick front
façade
68% brick High quality visually interesting and
durable building materials should
be used that include a mix of clay
brick/masonry and contemporary
cement board, wood, and metal
paneling as materials to accentuate
and create interest on the building.
Brick and similar materials should
wrap corners and be present on all
facades to maintain design
cohesiveness and interest.
Architectural None 2-Foot Parapet Buildings three-stories or greater in
35
4
Relief * Height, 8inch
projecting window
box, material
emphasis
height or requesting reduced
setbacks should minimize overall
massing with relief in the building
plane through recessed façade(s)
of at least 30 inches, variable roofs
forms, pitched roofs parallel to the
primary façade, and other
architectural treatments.
Windows 40 % of building
length
49% None
Accents Architectural details
to create visual
interest
Brick soldier
course, parapets,
lintels, 8”
projecting
windows, varying
material (brick,
Hardie panel &
board)
See Materials
Entrances * One main
pedestrian entrance
per primary façade
shall be recessed or
framed by a
sheltering element
such as an
overhang, arcade or
portico providing at
least six feet of
width and four feet
of depth that is
architecturally
integrated into the
overall design.
4x6 metal
overhangs
-Building orientation shall
emphasize a front to a building,
especially along Hyland Avenue,
with an identifiable main building
entrance.
-Alternatively, the Council may
approve a contemporary building
design accentuating modern
building materials and emphasizing
vertical elements of a building with
massing, roof elements, and corner
connections to a street.
Coverage/
Open Space
None 66% impervious None
Landscaping Front Yard-
Overstory trees,
shrubs, grasses.
Front Yard
ornamental trees
and ground
covers due to
reduced front
yard depth.
Additional
ornamental trees
in rear yard for
reduced setback.
None
Parking 1 Space per unit up
to 2 Bedrooms
13 units = 13
parking stalls
Design to deemphasize parking
appearance along the street.
36
5
Staff has highlighted the four specific applicant requests for Building A to support
alternative design features and application of O-WUPED requirements as proposed with
the MSDP that follow the table
Reduction in the rear yard setback to 20.5 feet from 25 feet.
Although a single-family home exists to the rear of the site, the adjacent property
is a very deep lot. The subject site is approximately 20 feet higher in elevation than
the house on Campus Avenue. Originally the project would have been a combined
site with a side setback requirement of 10 feet rather than a rear setback of 25 feet
for a three-story building. Staff supports the alternative design request to reduce
the rear yard setback to facilitate the project design. No specific landscape buffer
was required, but the applicant has included ornamental trees in the rear to soften
the transition.
Reduction of the walkway width to the front door from five feet to four feet adjacent
to the driveway.
Due to cross slope and the short distance to the street, staff supports this request.
The applicant requests that the Commission find the proposal consistent with the
design principles for architectural relief for buildings 3 -stories or greater in height
or requesting reduced setback based upon the variable 2-foot parapet heights, 8-
inch projecting window boxes, the changes in material with brick and siding to
create visual interest. (Design Principle 7.b.) The building is to be evaluated
against all the design principles for orientation, entrance design, building materials,
accents, etc. In this case the project includes many of the features listed in the
principles, but does not achieve the recommended 30 inches of relief due to the
site constraints and building size. Staff supports the design approach for
Building A due to its limited façade length of 64 feet along the street as not
necessitating substantial degrees of relief. The garage door is also inset to create
some change in façade depth at ground level.
The applicant asked that the Commission support an interpretation the front
setback can be further reduced from 20 feet to 15 feet as permitted by a
supplemental design standard for units facing the street at ground level.
(Supplement Design Standards) Staff does not believe that as designed the
supplement standard supports a 15-foot setback. The Commission agreed
the standard did not permit a 15 foot setback for single ground floor unit
access.
The 15-foot setback standard was designed for a building with multiple units
facing a street with their access directly to the street, e.g. townhome or walk-
up units. If a building does not have multiple units facing the street the
minimum setback is required to be 20 feet with an alternative design
approval.
37
6
Staff recommended to the applicant and Commission that the appropriate
approach to this building proposal is to seek a rear yard setback variance to
allow the building to shift 5 feet towards the rear and create a 20 -foot front
setback to conform to the alternative design allowances. The 20-foot
setback is also more in line with the existing front setbacks of apartment
buildings in the area that are commonly at 25 feet. The applicant has filed a
variance application with the intent of it being approved before 2nd reading
of the rezoning ordinance.
The owner proposes landscaping for Building A that is consistent with the requirements
of the zoning code. With the proposed reduced front yard 15 -foot setback, overstory trees
that are normally required with apartment buildings will not fit in the space. Subst itute
smaller trees are proposed as a result. If the setback increased overstory trees can be
added returned to the landscape plan.
Access is proposed through a 20-foot driveway along Hyland Avenue. The O -WUPED
allows for reduced driveway width to minimize the sidewalk crossings. Pedestrians can
access the site through sidewalks along the south side yard or to the front door of Hyland
adjacent to the driveway. No bike parking was specified for the building.
263 Hyland Building B- Discussion
Summary Table Major Standards for Building B. Items with a * discussed below.
Standard (allows
20% variation)
Proposed Principle/Supplemental
Standard
Front
Setback*
25 Feet
20 Feet to Hyland
Façade. 25 feet to
Oakland.
Front setback reduction
Supplemental Standard to 15 feet:
“15 feet for buildings with first floor
residential units facing the street.”
Side Setback 12 feet (4-stories) 15.37 feet and 51.8
feet
None
Height 45 feet 44.37 feet None
Rear
Setback
25 Feet
N/A on a Corner
Lot (two sides and
two fronts)
None
Primary
Façade
Maximum
Setback*
25 feet 26.03 feet (corner
of building at
Oakland)
Materials 60% brick front
façade
64% (Hyland) &
60% (Oakland)
brick
High quality visually interesting and
durable building materials should
be used that include a mix of clay
brick/masonry and contemporary
cement board, wood, and metal
38
7
paneling as materials to accentuate
and create interest on the building.
Brick and similar materials should
wrap corners and be present on all
facades to maintain design
cohesiveness and interest.
Architectural
Relief*
None 2-Foot Parapet
Height, 8inch
projecting window
box, material
emphasis
Buildings three-stories or greater in
height or requesting reduced
setbacks should minimize overall
massing with relief in the building
plane through recessed façade(s)
of at least 30 inches, variable roofs
forms, pitched roofs parallel to the
primary façade, and other
architectural treatments.
Windows 40 % of building
length
48% (Hyland) &
44% (Oakland)
None
Accents Architectural details
to create visual
interest
Brick soldier
course, parapets,
lintels, 8”
projecting
windows, varying
material (brick,
Hardie panel &
board)
See Materials
Entrances* One main
pedestrian entrance
per primary façade
shall be recessed or
framed by a
sheltering element
such as an
overhang, arcade or
portico providing at
least six feet of
width and four feet
of depth that is
architecturally
integrated into the
overall design.
4x6 metal
overhangs
-Building orientation shall
emphasize a front to a building,
especially along Hyland Avenue,
with an identifiable main building
entrance.
-Alternatively, the Council may
approve a contemporary building
design accentuating modern
building materials and emphasizing
vertical elements of a building with
massing, roof elements, and corner
connections to a street.
Coverage/O
pen Space
None 63% None
Landscaping Front Yard-
Overstory trees,
shrubs, grasses.
Parking Lot High
Screen and
Front Yard trees
and ground covers.
Alt Design for High
Screen with Fence
and Change of
None
39
8
Overstory Trees Trees
Parking 1 Space per unit up
to 2 Bedrooms
19 units = 19
parking stalls/21
provided
Design to deemphasize parking
appearance along the street.
Staff has highlighted specific applicant requests for Building B to support alternative
design features and application of O-WUPED requirements as proposed with the MSDP:
Maximum setback of 26.25 feet from Oakland rather than 25 feet.
Staff supports this relief as it applies to a corner of the building and the almost all
of the façade is otherwise at 25 feet along Oakland.
Reduction in the Hyland front yard setback to 20 feet from 25
The applicant narrative states 22 feet, but the site plan is set at 20 feet. Staff
generally supports the reduction to 20 feet, the front yard space is similar to typical
25-foot front setbacks along Hyland. Standard front yard landscaping for
apartments can still be accomplished with trees. However, staff addresses
building relief options related to height and setback below.
The applicant requests that the Commission find the proposal consistent with the
design principles for architectural relief for buildings 3 -stories or greater in height
or requesting reduced setback based upon the variable 2-foot parapet heights, 8
inch projecting window boxes, the changes in material with brick and siding to
create visual interest. (Design Principle 7.b.) The building is to be evaluated
against all the design principles for orientation, entrance design, building materials,
accents, etc. In this case the project includes many of the features listed in the
principles, but does not achieve the recommended 30 inches of relief due to the
site constraints.
Building B is 107 feet in length along Hyland compared to 64 feet for Building A.
Staff believes that the larger Building A should incorporate more design relief for
conformance with Principle 7.b. Staff offered an alternative to increase the setback
to 22 feet with adjustments to the rear parking area, which would allow for either
greater amounts of front yard setback open area or for building modulation along
the Hyland façade between 20 and 22 feet. The architect expressed that adding
additional relief with insets across the façade would be complicated by the building
design and interior floor plan considerations and were not feasible. Staff believes
a two-foot offset near the mid-point of the building would better achieve the intent
of the design principle for emphasizing relief than the current proposal.
The Commission did not add a condition to modify the design to add relief.
The applicant requested that the Commission find the proposal consistent with the
design principles for the primary entrance feature along Oakland wit h the 6-foot
canopy (Principles 7.a and f.) Design standards required an entrance per primary
façade, which in this case is defined as Oakland. Hyland is a secondary façade
because access is from Oakland. The project achieves the minimum design
40
9
standards for entrances and sheltering features.
However, the Design Principles of 7.a. and f. look at design emphasis of the
entrance features for identify and overall integration into the design.
a. Building orientation shall emphasize a front to a building, especially along
Hyland Avenue, with an identifiable main building entrance.
f. ….” Alternatively, the Council may approve a contemporary building design
accentuating modern building materials and emphasizing vertical elements of a
building with massing, roof elements, and corner connections to a street.”
The Commission concurred with staff about adding a condition to modify the
entrance.
Staff believes that the contemporary design does incorporate some of the
elements described in the principles to emphasize the entrance, primarily with the
vertical brick accent with the Oakland entrance, but it has not fully addressed the
intent of a presence along Hyland or to the corner. The proposed 6 x 4 -foot canopy
does scale to the doorway that leads to a stairwell, but it does not substantially
emphasize an entrance that matches the scale of the building. Staff identified an
option of extending the features of the entrance materials and canopy to the corner
and wrapping the corner to have a presence on Hyland. The canopy design could
be modified to be more substantial in size or converted to a covered porch type
element connecting extending more towards Hyland.
Landscaping is generally met. However, the applicant proposes an alternative landscape
related to the surface parking area with no over-story trees by removing three required
trees along the west parking area of the building and substituting the three trees for 27
Karl Foreseter Grasses along the property line. Additionally, the owner reque sts to
substitute the requirement of three overstory trees for four understory trees (grows to less
than 30 feet in height). The request is due to electrical power lines that run along the west
property line and the requirement that the trees do not interf ere with public utilities. The
configuration of the site with tall buildings and the retaining wall also inhibit parking lot
tree plantings. High Screening requirements are also needed to buffer the parking area
from the residential uses to the west. A retaining wall will be installed with a fence that
provides a minimum of a 6-foot screening element along the west property line.
41
10
GENERAL AND OTHER DEVELOPMENT STANDARDS
259 Hyland development is oriented toward Hyland Ave. A 20 -foot driveway provides
access to 13 internal ground floor parking spaces. The trash enclosure is incorporated
into the building near the garage entrance and is not expected to have a negative impact
on vehicle access or the appearance of the building.
263 Hyland development is oriented towards Oakland Street with an entry focal point
located at the corner of Hyland and Oakland. A 24-foot driveway provides access to the
site and both surface parking and garage parking for a total of 21 parking spaces. The
building offers both surface parking and internal garage parking. The trash enclosure is
located in the northwest corner of the parking lot outside of the front setback and is not
expected to have a negative impact on traffic or aesthetics.
Landscaping
Residential development requires a diverse mix of shrubs, grasses and trees to be
planted within the front yard and around the parking area. Each site meets the landscape
requirements.
However, an overhead utility line exists along the west property line. Tre es should not
grow to a maturity that may interfere with utilities. In the event of utility interference zoning
code states the following standard:
“If overhead utilities exist and are not planned to be placed underground, the
Planning Director may approve overstory trees to be substituted with alternative
locations for planting of trees or for the planting of smaller trees.”
The applicants proposes substituting the three required overstory trees located around
the parking area of the north building for smaller tress that will not interfere with the
overhead utility lines.
Signs and Lighting
No lighting plan has been submitted at this time. A lighting plan will need to be reviewed
and approved by staff prior to issuance of a building permit.
Infrastructure
Water, storm sewer, sanitary sewer mains, and electric service are all located in close
proximity to the site. Connections will primarily be from Hyland. A short closure of Hyland
is expected to make connections.
Stormwater Management
42
11
The site is subject to conformance with Municipal Code Chapter 5a and 5b requirements
for stormwater control and treatment. The Public Works Department has reviewed the
submitted plans and has concluded that existing stormwater facilities can handle the
increased runoff from the construction of the building.
Major Site Development Plan Criteria. The standards are found in Ames Municipal
Code Section 29.1502(4)(d) and include the following requirements. When acting upon
an application for a Major Site Development Plan approval, the Planning and Zoning
Commission and the City Council shall rely upon generally accepted site planning
criteria and design standards. These criteria and standards are necessary to fulfill the
intent of the Zoning Ordinance, the Comprehensive PLan, and are the minimum
necessary to safeguard the public health, safety, aesthetics, and general welfare.
43
12
Major Site Development Plan Criteria
1. The design of the proposed development shall make adequate provisions for
surface and subsurface drainage to limit the rate of increased runoff of surface
water to adjacent and downstream property.
The site is less than 1-acre and exempt from mandatory Chapter 5b stormwater
treatment measures. The project includes drainage design that dire ct water from the
site to the existing storm sewer system. It does not detain water on site.
2. The design of the proposed development shall make adequate provision for
connection to water, sanitary sewer, electrical, and other utility lines within the
capacity limits of those utility lines.
The existing utilities were reviewed and found adequate to support the anticipated
load of the proposed development. There are no offsite upgrades needed to serve the
site for any utility.
3. The design of the proposed development shall make adequate provision for fire
protection through building placement, acceptable location of flammable
materials, and other measures to ensure fire safety.
The fire inspector has reviewed access and fire truck circulation and found tha t the
needs of the Fire Department are met for access and circulation.
4. The design of the proposed development shall not increase the danger of
erosion, flooding, landslide, or other endangerment to adjoining and
surrounding property.
It is not anticipated that this proposed development will be a danger due to its location
on the site, the flatness of the parcel, and the distance from a floodplain.
5. Natural topographic and landscape features of the site shall be incorporated
into the development design.
The applicant is working with the existing topography of the site. The disturbed areas
of the site are required to come into compliance with current landscape requirements.
6. The design of the interior vehicle and pedestrian circulation shall provide for
convenient flow of vehicles and movement of pedestrians and shall prevent
hazards to adjacent streets or property.
The proposed developments will provide for vehicular access off Hyland and
Oakland. Each site will function independently, and shared access or cross access
is not proposed. The sidewalks onsite will connect with the public sidewalks along
Hyland Ave and Oakland Street.
44
13
7. The design of outdoor parking areas, storage yards, trash and dumpster areas,
and other exterior features shall be adequately landscaped or screened to
minimize potential nuisance and impairment to the use of adjoining property.
The parking area is screened to meet front yard landscaping requirements along
Hyland Ave and Oakland Street. The trash enclosure for 259 Hyland will be
incorporated in the building, use similar building materials for complete screening, and
be further screened by landscaping. The trash enclosure for 263 Hyland will use
similar building materials for complete screening and be further screened by
landscaping. The enclosures meet the zoning requirements for solid waste collection
areas.
8. The proposed development shall limit entrances and exits upon adjacent streets
in order to prevent congestion on adjacent and surrounding streets and in order
to provide for safe and orderly vehicle movement.
Access to the proposed developments will be from Hyland Avenue and Oakland
Avenue in the general locations of the existing access points.
9. Exterior lighting shall relate to the scale and location of the development in
order to maintain adequate security, while preventing a nuisance or hardship to
adjacent property or streets.
All lighting will be required to comply with the City’s Outdoor Lighting code. Lighting
will be reviewed by staff prior to the issuance of a b uilding permit.
10. The proposed development shall ensure that dust and other forms of air
pollution, noise disturbances, odor, glare, and other nuisances will be limited
to acceptable levels as prescribed in other applicable State and City regulations.
The proposed development is not expected to generate any nuisances.
11. Site coverage, building scale, setbacks, and open spaces shall be in proportion
with the development property and with existing and planned development and
structures, in adjacent and surrounding property.
Site coverage and building scale is generally consistent with the surrounding
development. Please see the setback discussion in the report above.
45
14
Location Map
46
15
Zoning Map
47
16
RN-4 Comp Plan Excerpt
48
H:\HUNZI\24X135505000\1_Corres\C_To Others\2026.07.31 - City Submittal\HYLAND APARTMENTS - Rezoning Narrative.docx
Rezoning Narrative
Date: August 4, 2026
To: City of Ames
From: Greg Broussard, PE
Subject: Hyland Apartments
259 & 263 Hyland, Ames, IA 50010
Hunziker Development
1. Reasons for Requesting Rezoning
a. Rezoning is requested to change from Residential High Density (RH) with an overlay of
West University Impacted District (O-UIW) to Residential High Density (RH) with an
overlay of West University Pedestrian Enhancement District (O-WUPED) for construction
of apartments located at the SW corner of Hyland and Oakland in Ames
2. Consistency with Ames Plan 2040, the City of Ames Comprehensive Plan
a. Ames Plan 2040 designates the Hunziker properties at the corner of Oakland and Hyland,
along with the surrounding area, as RN-4 “ Walkable Urban Neighborhood.” The
purpose of the Designation is to encourage higher density housing, mixed uses,
walkability, and redevelopment that creates a high-quality built environment and sense
of place. Addition of the O-WUPED overlay will help meet the goals of the RN-4 zone by
reducing parking, adjusting setbacks and increasing density allowances. The O-WUPED
zone was create to help projects like the proposed development be approved and to help
meet the goals of Ames Plan 2040
3. Proposed Use
a. The proposed use will be to create two new apartment buildings on the site.
4. Masterplan
a. No required since there is a major site development plan
5. Rezoning Map
a. Rezoning map has been submitted for the parcel
49