HomeMy WebLinkAboutA050 - Third reading and adoption of ORDINANCE NO. 4890 revising Municipal Code Chapter 28 for Water Meter setting requirementsTo:Mayor & City Council From:John Dunn, Director of Water & Pollution Control Date:March 24, 2026 Subject:Water Meter setting requirements Item No. 54 MEMO The ordinance revising Municipal Code Chapter 28 for Water Meter setting requirements is attached for City Council's review and consideration for third reading and adoption. ATTACHMENT(S): Ordinance Section 28.209(2) New Water Meters.PDF Water & Pollution Control 515.239.5105 main 515.239.5142 fax 515 Clark Ave. P.O. Box 811 Ames, IA 50010 www.CityofAmes.org 1 ORDINANCE NO. ___________ AN ORDINANCE TO AMEND THE MUNICIPAL CODE OF THE CITY OF AMES, IOWA, BY AMENDING SECTION 28.209(1) THEREOF, FOR THE PURPOSE OF AMENDING STANDARD WIRING AND INSTALLATION REQUIREMENTS FOR TRANSISTION TO NEW WATER METER DEVICES REPEALING ANY AND ALL ORDINANCES OR PARTS OF ORDINANCES IN CONFLICT TO THE EXTENT OF SUCH CONFLICT; AND ESTABLISHING AN EFFECTIVE DATE. BE IT ENACTED, by the City Council for the City of Ames, Iowa, that: Section One. The Municipal Code of the City of Ames, Iowa shall be and the same is hereby amended by amending Section 28.209(1) as follows: “Sec. 28.209. RADIO READ DEVICE (1) New meter installations. All new water meter installations shall have a radio read device. Any residential dwelling units located within the City of Ames municipal electric service territory may have the radio read device located inside the dwelling. All commercial buildings, located within the City of Ames municipal electric service territory, and any residential or commercial buildings located outside of the City of Ames municipal electric utility territory, shall install, For each meter, a 22/3 gauge, stranded, shielded wire with plastic sheath shall be installed from the water meter on the inside of the building to within three feet of the electric meter on the outside of the building. Meters located in meter pits or vaults shall have the radio read device located inside the pit or vault or located in a pedestal near the meter pit or vault. If the electric meter is located on a transformer, or other remote location, the wiring for the radio read device shall terminate on the side of the building nearest the transformer or remote location. A minimum of three feet of excess wire shall be left at each end to allow connection to the water meter and installation of the radio read device. Any portion of the wire that will not be exposed (i.e., installed behind finished walls, above finished ceilings, etc.) shall be placed in conduit to protect the wire from damage and to facilitate replacement if necessary. The City will provide and install the radio read device and connect it to the customer-installed wire. * * * .” 2 Section Two. All ordinances, or parts of ordinances in conflict herewith are hereby repealed to the extent of such conflict, if any. Section Three. This ordinance shall be in full force and effect from and after its passage and publication as required by law. Passed this day of , 2026. __________________________________________________________ John A. Haila, Mayor First Reading:__________________ Second Reading:_______________ Third Reading:_________________ Passed on: I, Renee Hall, City Clerk of the City of Ames, Iowa, hereby certify that the above and foregoing is a true copy of Ordinance No. ______________, passed by the City Council of said City at the meeting held on ______________________and signed by the Mayor on ___________________________, and published in the Ames Tribune on ___________________________. _______________________________ Renee Hall, City Clerk 3