Loading...
HomeMy WebLinkAboutA001 - Salvage Yard Special Use Permit and staff report dated March 12, 2025ITEM #: 3 DATE: 03-26-2025 CITY OF AMES DEPARTMENT OF PLANNING AND HOUSING REPORT TO THE ZONING BOARD OF ADJUSTMENT REQUEST: Public Hearing on a request for a Special Use Permit for a new Building and Truck Scale at a Salvage Yard within the General Industrial (GI) Zoning District. BACKGROUND: The applicant, Matt Bell on behalf Charles Bell, dba Bell Salvage is requesting approval of a Special Use Permit to add a new industrial building and truck scale at a Salvage Yard located at 501 Freel Drive. The Special Use Permit request is accompanied by a Site Development Plan. The site is zoned General Industrial (GI). The site is also located within the 100-year Floodplain. The existing site is 5.02 acres on the west side of Freel Drive. Bell Salvage currently has a scale on the other side of Freel Drive. The new facility will allow for a better flow of trucks, more convenient unloading of material, and updated equipment. Any development activity for a Salvage Yard Use requiring a Site Development Plan must be accompanied by a Special Use Permit. This site was originally granted a Special Use Permit in 1992. The site has operated as a permitted Salvage Yard since that time with some minor updates and amendments throughout the years. The owner is requesting to construct a 4,200 square foot building in the center of the site along with a new truck scale for weighing materials that are brought to the site. Additionally, paved parking will be constructed for the new building and paving of drive aisle access from the parking area and scale location to Freel Drive. The building is being constructed for workshop space and sorting of materials from customers onto trucks. A small exiting building near the front of the site will be demolished to make way for this project. The project will not expand the existing stockpiles approved on the original Special Use Permit. Stockpiling will still occur to the north, west and southwest of the new building and truck scale. Front yard landscaping of trees, shrubs and grasses and parking lot landscaping is being proposed in accordance with the Landscape standards in Chapter 29.403. The project will require 10 parking stalls which are being provided directly north of the new building. The area along Freel Drive where the new building and scale is proposed will be permitted to remove the existing screen wall as there will be landscaping and open front yard with the new building being constructed. (The original SUP required screening fences along Freel Drive.) This will help screen and soften against the stockpiles behind the building. This will be between the south entrance immediately south of the new building and north entrance immediately north of the new building. The new truck scale will facilitate truck weighing on-site. Currently trucks are weighed off site on the east side of Freel opposite of this location and then travel to the salvage yard to process material. The new scale will have trucks entering from Freel east of the new scale and circulating around to the north and exiting north of the new building. This will contain operations of weighing and breaking items down on one site. Staff is conditioning that the existing screen wall that is required to screen the site on the north, south and remaining portions along the east property boundaries along Freel Drive be repaired in any area it is damaged. Staff is requiring that with any approval of the proposed plan that all of the other requirements from the previous Special Use Permit remain. This includes a chain-link gate system at the entrance to the site. Staff is also requiring that a tire pile near the center of the site be removed to comply with the original Plan and the Fire Code. The Fire Inspector has safety concerns about the size of the existing accumulation. The site is located within the 100-year floodplain. The proposed building and any other electrical or mechanical items on site are required to be elevated to 3’ above the Base Flood Elevation (BFE). This helps to ensure a greater degree of protection for the building and any vital electrical or mechanical equipment that may be prone to damage. In the case of the building this applies to the lowest floor of the building which in the case is the building pad. The proposed lowest floor of the building is proposed to be 3’ above the BFE of the site. In the case of the truck scale this applies as well. The scale is proposed at 3’ above the BFE. STATEMENT OF APPLICANT IN SUPPORT OF PROPOSAL: The applicant’s complete application and supporting information accompany this report. These materials discuss characteristics of the proposed use and their impacts. The applicant states the appearance of the building and site will not need to be altered to accommodate the use (other than the addition of an entrance door) and that the proposed use will not negatively impact any of the other businesses in the area. APPLICABLE LAW: Chapter 29, Section 29.1503(5)(a) and (e) of the Municipal Code states the following: (5) Review Criteria. Before a Special Use Permit application can be approved, the Zoning Board of Adjustment shall establish that the following general standards, as well as the specific standards outlined in subsections (b), (c), and (d) below, where applicable, have been or shall be satisfied. The Board's action shall be based on stated findings of fact. The conditions imposed shall be construed as limitations on the power of the Board to act. A mere finding that a use conforms to those conditions or a recitation of those conditions, unaccompanied by specific findings of fact, shall not be considered findings of fact for the purpose of complying with this Ordinance. (a) General Standards. The Zoning Board of Adjustment shall review each application for the purpose of determining that each proposed use meets the following standards, and in addition, shall find adequate evidence that each use in its proposed location will: [The standards are listed in this report below.] …. (e) Conditions. The Board may impose such additional conditions it deems necessary for the general welfare, for the protection of individual property rights, and for ensuring that the intent and objectives of this Ordinance will be observed." Chapter 29.1306 Salvage Yards (1) It is found that the keeping of salvaged parts and materials and the storage of motor vehicles out of doors can detract from the beneficial use and enjoyment of neighboring properties. A salvage yard is prohibited anywhere except in the GI Zone. Such salvage yard shall be authorized only by a Special Use Permit issued after a public hearing by the Zoning Board of Adjustment in accordance with the procedures set out in Section 29.1503 and shall be subject to such protective conditions that may be warranted by the nature of the salvage operation. A salvage yard operation is also subject to all the submittal and approval requirements set out in Section 29.901. (2) The Zoning Board of Adjustment shall not grant any Special Use Permit as authorized and required in Subsection A above, unless it shall first find as a fact that the keeping of motor vehicles that are stored or displayed under their present or proposed conditions or circumstances will not: (a) Provide an attractive and dangerous nuisance for young children; (b) Be a harborage for rats and other forms of vermin; or (c) Be an unsightly detraction from the use and enjoyment of adjacent properties. In granting a Special Use Permit, the Zoning Board of Adjustment may impose such time limits and other special protective conditions as it shall find useful and reasonable to the concerns expressed in Subsections a, b, and c above. PUBLIC NOTIFICATION: Notification was made to all owners of property within 200 feet. A notice of public hearing was placed on the property and published in the newspaper. As of this writing, no comments have been received. ALTERNATIVES: 1. The Zoning Board of Adjustment can approve the requested Special Use Permit to construct a Building and Truck Scale at 501 Freel Drive for a Salvage Yard business with the following conditions: a. The requirements of the previously issued Special Use Permit to operate the Salvage Yard apply for area not affected by this request. b. That the required high screen wall be repaired in any area it is in a state of disrepair prior to issuance of a certificate of occupancy for the new building. c. A tire pile located on site must be removed prior to occupancy of the new building. d. The chain-link fence and gate system be maintained where the screen walls are being removed. 2. The Zoning Board of Adjustment can approve the requested Special Use Permit to construct a Building and Truck Scale at 501 Freel Drive for a Salvage Yard business with its own set of conditions. 3. The Zoning Board of Adjustment can deny the requested Special Use Permit to construct a Building and Truck Scale at 501 Freel Drive for a Salvage Yard business. PLANNING AND HOUSING DEPARTMENT RECOMMENDED ACTION: The request to construct a Building and a Truck scale here has been reviewed by Staff and meets the City’s General Industrial (GI) zoning requirements and floodplain requirements. The building is not increasing the area of coverage of salvage piles or the extent of the Salvage Yard Use. The proposed Building and Truck Scale will require paved parking and paved access from Freel Drive as well as front yard landscaping and green space. Staff believes that the appearance of this section of the site will be enhanced by adding landscaping and the proposed new Building. Staff also believes all of the Special Use Permit general standards and Salvage Yard standards have been met. Based upon review of the operations and the findings of fact for the Special Use Permit included in the addendum, the Planning & Housing Department recommends Alternative #1 with the attached conditions. Addendum FINDINGS OF FACT & CONCLUSIONS: Based upon the submitted site plan in addition to the facts provided in the application, the following findings of fact and conclusions may be made regarding the standards of approval. General Standards. (i) Be harmonious with and in accordance with the general principles and proposals of the Comprehensive Plan of the City. Findings of Fact: The land use designation here is ‘Employment’ and supports Industrial activities such as the proposed use and current use. The zoning designation of General Industrial is supported by Ames Plan 2040 and the site will operate according to the zoning designation. Conclusions: The proposed building and truck scale will serve the existing business and use of the property which is supported by Ames Plan 2040. This standard can be found to be met. (ii) Be designed, constructed, operated and maintained so as to be harmonious and appropriate in appearance with the existing and intended character of the general vicinity and that such a use will not change the essential character of the area in which it is proposed. Findings of Fact: The proposed new building and truck scale have been designed to comply with the zoning standards in Chapter 29 of the Ames Municipal Code and Chapter 9 of the City’s Floodplain Ordinance. The proposed use of the building is industrial, and the proposed design is typical of other buildings in the General Industrial Zone. The building meets and exceeds required setbacks and meets minimum height requirements. The proposed truck scale is being moved to this site from across the street on the east side of Freel Drive. The proposal will add landscaping and paving on site. A separate salvage operation exists adjacent to this site to the southeast. Conclusions: The proposed new building and truck scale are permissible in the General Industrial zone. The use of the property will remain as it has been since the 1990’s as a Salvage Yard. This use can be expected to occur in this area and a separate salvage business exists nearby. This standard can be found to be met. (iii) Not be hazardous or disturbing to existing or future uses in the same general vicinity. Findings of Fact: The proposed site plan is for construction of an industrial building to serve the Salvage Yard use and construction of a truck scale to weigh material. The development affects only the central portion of the site. The salvage use will continue as it has been under the previously approved Special Use Permit in the 1990’s. No additional uses are being added to the site. Conclusions: The current use and activity have been in place since the 1990’s. The addition of the building and truck scale are permitted uses and function as part of the salvage use. The addition of the building and scale are not seen to create a disturbance to existing or future uses. This standard can be found to be met. (iv) Be served adequately by essential public facilities and services such as highways, streets, police, fire protection, drainage structures, refuse disposal, water and sewage facilities, and/or schools. Findings of Fact: The site is served by Freel Drive. The new building will be connecting to City water and sewer that already exists along Freel Drive. The site will continue to be served by Freel Drive adequately. No other City services are required or will be affected. According to the owner, traffic levels on this section of Freel Drive are not anticipated to increase as a result of the new building and truck scale. Conclusions: City services are adequate to serve this site. The proposed development is not seen to create an undue burden or require additional unforeseen City services. This standard can be found to be met. (v) Not create excessive additional requirements at public cost for public facilities or services. Findings of Fact: No additional public serves are required to serve this development. Conclusions: This standard can be found to be met. (vi) Not involve uses, activities, processes, materials, and equipment or conditions of operation that will be detrimental to any person, property, or general welfare by reason of excessive production of traffic, noise, smoke, fumes, glare, or odors. Findings of Fact: The Salvage Yard activities here have been ongoing for several decades. The proposal is for construction of a building and a truck scale to serve the existing salvage use. Paved parking and landscaping will also be constructed. Traffic levels to the business on Freel Drive are not anticipated to change according to the applicant. The proposed site plan will not expand the salvage yard beyond the existing site it is located on. Conclusions: This standard can be found to be met. (vii) Be consistent with the intent and purpose of the Zone in which it is proposed to locate such use. Findings of Fact: The General Industrial zone is intended for Industrial uses which include Salvage Yards, subject to a Special Use Permit approval. The proposed building and truck scale meet General Industrial and General Development standards in Chapter 29. Conclusions: The proposed industrial building, paved parking and truck scale comply with the General Industrial zone standards. This standard can be found to be met. CONCLUSION: Based on the staff’s analysis and the findings above, staff finds that the General Standards of the Ames Municipal Code Section 29.1503(5)(a) can be satisfied. Salvage Yard Criteria (i) Provide an attractive and dangerous nuisance for young children; Findings of Fact: The proposed site plan for a building and truck scale will not expand the size of the salvage yard. The screen wall around the site is being maintained which will limit access to the site. The site is not located in the immediate vicinity of a residential neighborhood or school. The only access to the site will be from Freel Drive along the east side of the site. The owner states motion activated cameras will be installed. The site will be supervised during regular business hours. A chain-link gate system will remain in place. Conclusions: The site is not easily accessible on all sides and is not located near a residential area or schools. The construction of the building and truck scale are not seen to create elements a more attractive and dangerous nuisance for young children. This standard can be found to be met. (ii) Be a harborage for rats and other forms of vermin; Findings of Fact: The proposed site plan will not expand the salvage yard storage activity. The development activity here will be for an industrial building and a truck scale with paved parking and access. Conclusions: The addition of a new building and truck scale is not seen to add to or increase the risk or presence of rats or other forms of vermin. This standard can be found to be met. (iii) Be an unsightly detraction from the use and enjoyment of adjacent properties. Findings of Fact: The current Salvage Yard has existed for many years and has a high screen wall as required in a previous Special Use Permit. The development here will involve construction of a building and a truck scale with paved access and parking. Conclusions: The creation of a building and truck scale is not unexpected in the General Industrial zone. The request does not expand the size of the salvage yard or increase intensity in such a way that neighboring properties cannot be utilized. This standard can be found to be met. Attachment A- Location Map LINCOLN WAY SE 5TH STREET FR E E L D R I V E S D A Y T O N A V E N U E PROJECT LOCATION SHEET C.100CGA PROJECT NO. 24-DA-0464 BELL SALVAGE SITE IMPROVEMENTS AMES, IOWA ~2025~ J: \ 2 4 - D A - 0 4 6 4 \ d w g s \ 5 _ S h e e t s \ 2 4 D A 0 4 6 4 - C . 1 0 0 ( T i t l e L e g e n d ) . d w g - C . 1 0 0 - 0 2 - 1 4 - 2 5 - 1 1 : 5 0 a m - s p e t e r s Pages or sheets covered by this seal: Signature Date I hereby certify that this engineering document was prepared by me or under my direct personal supervision and that I am a duly licensed Professional Engineer under the laws of the State of Iowa. OI AW 25470 CLI DESEN RP EFO SS O LNAI GNE INEER My license renewal date is December 31, 2026 Iowa License Number 25470 Brad A. Freeman, PE RAD A .FREEMANB Clapsaddle-Garber Associates, Inc 2413 Grand Avenue Des Moines, Iowa 50312 Phone 515-288-4823 www.cgaconsultants.com INDEX OF SHEETS SHEET NO. DESCRIPTION C.100 TITLE SHEET C.101 SYMBOLS, LEGEND AND GENERAL INFORMATION C.110 EXISTING CONDITIONS & DEMOLITION PLAN C.200 SITE PLAN C.201 OVERALL SITE LAYOUT C.300 GRADING PLAN C.400 LANDSCAPE PLAN C.500 DETAILS C.501 DETAILS CONTINUED LOCATION MAP Council Bluffs Sioux City Burlington Des Moines I-80 Mason City I-35 Waterloo Marshalltown Davenport Dubuque Cedar RapidsAMES VICINITY MAP NOT TO SCALE WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE IOWA STATEWIDE URBAN STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS, CURRENT EDITION (SUDAS) AND THE CITY OF AMES STANDARD SPECIFICATIONS PRELIM I N A R Y N PLAN SET IS INTENDED TO BE PRINTED IN COLOR. PRINTING WITHOUT COLOR MAY AFFECT LEGIBILITY OF THE PLANS Attachment B- Site Development Plan SHEET NO. DRAWN: CHECKED: DATE: DATE: APPROVED:DATE: PROJECT NO.DESIGNED:DATE:REVISIONNO.DATEBY DATEBYREVISIONNO. J: \ 2 4 - D A - 0 4 6 4 \ d w g s \ 5 _ S h e e t s \ 2 4 D A 0 4 6 4 - C . 1 0 0 ( T i t l e L e g e n d ) . d w g - C . 1 0 1 - 0 2 - 1 4 - 2 5 - 1 1 : 5 0 a m - s p e t e r s CGA BELL SALVAGE SITE IMPROVEMENTS C.101 24-DA-0464 AMES, IOWA -------- -------- -------- -------- SYMBOLS, LEGEND, AND GENERAL INFORMATION Clapsaddle-Garber Associates, Inc 2413 Grand Avenue Des Moines, Iowa 50312 Ph 515-288-4823 www.cgaconsultants.com Zoning Compliance Summary (Based upon Chapter 29, Zoning & Chapter 9, Flood Plains Zoning Regulations of the City of Ames, County of Story, State of Iowa, in current usage) CRITERION REQUIRED/PERMITTED PROPOSED PRIMARY CODE REFERENCE Applicable Zoning District General Industrial - GI Zoning Map & FIRM Principal Permitted Use Salvage Yard Salvage Yard 29.901(2) Minimum Lot Area in Square Feet No Limit 86,825 SQ.FT.29.901(3) Minimum Lot Frontage in Feet 25 FT 216.56 FT 29.901(3) Minimum Front Lot Line 10 FT 95.33 FT 29.901(3) Minimum Side Lot Line 12 FT 75.33 FT 29.901(3) Minimum Rear Lot Line 20 FT 236.93 FT 29.901(3) Maximum Building Coverage in Percent 85%5%29.901(3) Minimum Landscape Area in Percent 15%13.6%29.901(3) Maximum Building Height in Feet or Stories 100 FT or 9 Stories 23 FT 29.901(3) Parking Allowed Between Buildings & Streets Yes No 29.901(3) Drive-Through Facilities Permitted Yes No 29.901(3) Outdoor Display Permitted Yes Yes 29.901(3) Outdoor Storage Permitted Yes Yes 29.901(3) Trucks & Equipment Permitted Yes Yes 29.901(3) Parking Spaces Required 7 Spaces 6 Spaces + 1 Handicap = 7 Spaces LEGEND EXISTING PROPOSED EVERGREEN TREE DECIDUOUS TREE FRUIT TREE SHRUBS (BUSHES) TREE LINE STUMP SWAMP CEMETERY GRAVE CAVE SINK HOLE WELL WINDMILL CISTERN SEPTIC TANK LP GAS TANK UNDERGROUND STORAGE TANK SATELLITE DISH SIGN (TYPE AS NOTED) FLAGPOLE SOIL BORING MONITORING WELL PARKING METER MAILBOX POST BOLLARD SPRINKLER HEAD SPRINKLER HEAD VALVE GUARDRAIL (BEAM OR CABLE) FENCE TILE OUTLET DRAINAGE WAY EDGE OF WATER SILT FENCE CONTOUR LINE SPOT ELEVATION BUILDING F F G CV SH W C ST LP UST SIGN PM PM P P B B SPH SPV X X O O 105 00.0 0 EXISTING PROPOSED WATERLINE WATER VALVE FIRE HYDRANT WATER METER CURB STOP YARD HYDRANT FIRE DEPT. CONNECTION POST INDICATOR VALVE SANITARY SEWER LINE STORM SEWER LINE DRAIN TILE SUBDRAIN MANHOLE CLEANOUT INTAKE BEEHIVE INTAKE ROOF DRAIN ROOF DRAIN (SURFACE) ROOF DRAIN (UNDERGROUND) GAS LINE GAS VALVE GAS METER OVERHEAD ELECTRICAL LINE BURIED ELECTRICAL LINE POWER POLE ELECTRICAL METER ELECTRICAL HIGHLINE TOWER TRAFFIC SIGNAL TRAFFIC SIGNAL LINE STREET LIGHT LUMINAIRE ELECTRICAL BOX/TRANSFORMER FIBER OPTICS LINE FIBER OPTICS BOX FIBER PEDESTAL TELEPHONE LINE TELEPHONE POLE TELEPHONE PEDESTAL TELEPHONE BOX CABLE TELEVISION LINE TELEVISION PEDESTAL TELEVISION BOX AIR CONDITIONER W (*)W W W FDC FDC PIV PIV San(*)San StS (*)StS DT DT SD SD M C C R R RS RS RU RU G (*)G G G OH E OH E E (*)E E E TS(*)TS FO(*)FO FO FO FO FO T(*)T T T T T TV TV TV(*)TV TV TV AC AC EXISTING PROPOSED SECTION/R.O.W. LINE BOUNDARY LINE PROPERTY LINE EASEMENT LINE SETBACK LINE R.O.W. RAIL OR LOT CORNER CONCRETE MONUMENT GOVERNMENT CORNER MONUMENT PARCEL OR LOT CORNER MONUMENT TEMP. CONSTRUCTION EASEMENT CORNER SURVEY CONTROL POINT PROPERTY ADDRESS: OWNER OF RECORD: 501 FREEL DRIVE AMES, IOWA 50010 CHARLES R BELL 500 FREEL DRIVE AMES, IOWA 50010 APPLICANT: BELL SALVAGE 500 FREEL DRIVE AMES, IOWA 50010 FIELD WORK COMPLETED: 11-01-2024 SURVEY PREPARED BY: SITE PLAN PREPARED BY: DATE OF PREPARATION: 01-28-2024 LEGAL DESCRIPTION LOTS NINETEEN (19) AND TWENTY (20) IN WOODLAND ACRES, A PLAT OF THE WEST HALF (W1/2) OF THE NORTHEAST QUARTER (NE1/4) OF SECTION TWELVE (12), TOWNSHIP EIGHTY-THREE (83) NORTH, RANGE TWENTY-FOUR (24) WEST OF THE 5TH P.M., STORY COUNTY, IOWA. CONTAINING 86,825 SQUARE FEET (1.99 ACRES). PROPOSED USE SALVAGE YARD PROJECT MANAGER: BRAD FREEMAN CLAPSADDLE-GARBER ASSOCIATES, INC 2413 GRAND AVENUE DES MOINES, IOWA 50312 PH 515-288-4823 WWW.CGACONSULTANTS.COM CLAPSADDLE-GARBER ASSOCIATES, INC 2413 GRAND AVENUE DES MOINES, IOWA 50312 PH 515-288-4823 WWW.CGACONSULTANTS.COM THE FOLLOWING UTILITIES ARE PRESENT ON THIS PROJECT UTILITY COMPANIES NOTE: Alliant Energy Field Engineer 800-255-4268 City of Ames Utility Maintenance Lisa Mondt 515-239-5162 Ames Electric Services Mark Carran 515-239-5189 MediaCom Wolfgang Spencer 845-587-2497 Metro FiberNet LLC Lori Kemper 812-213-1050 UNDERGROUND STRUCTURES, FACILITIES, AND UTILITIES HAVE BEEN PLATTED FROM AVAILABLE SURVEYS, RECORDS AND DEEDS. THEREFORE THEIR LOCATIONS MUST BE CONSIDERED APPROXIMATE ONLY. THERE MAY BE OTHERS, THE EXISTENCE OF WHICH IS PRESENTLY NOT KNOWN. TYPICAL DEPTH OF COVER ON WATERMAIN PIPE IN AMES IS 5.5 FT. VALUE ENGINEERING SAVES. REFER TO ARTICLE 1105.15 OF THE SPECIFICATIONS. NOTES: 1. ALL BEARINGS ARE THE RESULT OF G.P.S. OBSERVATIONS. 2. ALL UNDERGROUND UTILITIES ON THIS SITE HAVE BEEN LOCATED AT ASCE LEVEL C OR D SURVEY QUALITY. 3. UTILITY LINETYPES WITH A QUALITY LEVEL INDICATOR (*) HAVE BEEN LOCATED PER THE FOLLOWING ASCE STANDARD GUIDELINE FOR THE COLLECTION & DEPICTION OF EXISTING SUBSURFACE UTILITY DATA" : (A)- PRECISE HORIZONTAL & VERTICAL LOCATION OF UTILITIES OBTAINED BY THE ACTUAL EXPOSURE (OR VERIFICATION OF PREVIOUSLY EXPOSED & SURVEYED UTILITIES) & SUBSEQUENT MEASUREMENT OF SUBSURFACE UTILITIES, USUALLY AT A SPECIFIC POINT. MINIMALLY INTRUSIVE EXCAVATION EQUIPMENT IS TYPICALLY USED TO MINIMIZE THE POTENTIAL FOR UTILITY DAMAGE. A PRECISE HORIZONTAL & VERTICAL LOCATION, AS WELL AS OTHER UTILITY ATTRIBUTES, IS SHOWN ON PLAN DOCUMENTS. ACCURACY IS TYPICALLY SET TO 15- MM VERTICAL & TO APPLICABLE HORIZONTAL SURVEY & MAPPING ACCURACY AS DEFINED OR EXPECTED BY THE PROJECT OWNER. (B)- INFORMATION OBTAINED THROUGH THE APPLICATION OF APPROPRIATE SURFACE GEOPHYSICAL METHODS TO DETERMINE THE EXISTENCE & APPROXIMATE HORIZONTAL POSITION OF SUBSURFACE UTILITIES. QUALITY LEVEL B DATA SHOULD BE REPRODUCIBLE BY SURFACE GEOPHYSICS AT ANY POINT OF THEIR DEPICTION. THIS INFORMATION IS SURVEYED TO APPLICABLE TOLERANCES DEFINED BY THE PROJECT & REDUCED ONTO PLAN DOCUMENTS. (C)- INFORMATION OBTAINED BY SURVEYING & PLOTTING VISIBLE ABOVE-GROUND UTILITY FEATURES & BY USING PROFESSIONAL JUDGEMENT IN CORRELATING THIS INFORMATION TO QUALITY LEVEL D INFORMATION. (D)- INFORMATION DERIVED FROM EXISTING RECORDS OR ORAL RECOLLECTIONS. CONTROL POINTS: IOWA REGIONAL COORDINATE SYSTEM IOWA NORTH NAD83(2011)(EPOCH 2010) IARTN DERIVED -US SURVEY FEET NUMBER NORTHING EASTING ELEV.DESCRIPTION 550 3469455.73 4896987.20 885.81 60D NAIL 800 3469511.80 4896930.02 885.40 PAVEMENT NAIL 801 3469389.44 4896929.90 884.96 CUT 'X' BENCHMARKS NORTH AMERICAN VERTICAL DATUM OF 1988 (NAV88-GEOID83A) IARTN DERIVED-US SURVEY FEET NUMBER NORTHING EASTING ELEV.DESCRIPTION 518 3469037.57 4896977.95 885.19 BURY BOLT ON HYDRANT 519 3469442.19 4896993.51 887.39 BURY BOLT ON HYDRANT ABBREVIATIONS PCC PORTLAND CEMENT CONCRETE ACC ASPHALT CEMENT CONCRETE STM STORM SEWER MANHOLE INT STORM SEWER INTAKE INT-MH STORM SEWER INTAKE WITH MANHOLE STCO STORM SEWER CLEANOUT FES STORM SEWER FLARED END SECTION STP STORM SEWER PIPE STFM STORM SEWER FORCE MAIN SMH SANITARY SEWER MANHOLE SACO SANITARY SEWER CLEANOUT SAP SANITARY SEWER PIPE SAFM SANITARY SEWER FORCE MAIN FH FIRE HYDRANT ASSEMBLY YH YARD HYDRANT ASSEMBLY WV WATER VALVE CS CURB STOP PIV POST INDICATOR VALVE FDC FIRE DEPT. CONNECTION RCP REINFORCED CONCRETE PIPE CMP CORRUGATED METAL PIPE HDPE HIGH-DENSITY POLYETHYLENE PIPE PVC POLYVINYL CHLORIDE PIPE DI DUCTILE IRON PIPE CP SURVEY CONTROL POINT BM SURVEY BENCHMARK SB SOIL BORING MW MONITORING WELL PM PARKING METER SH SPRINKLER HEAD GV GAS VALVE GM GAS METER PP POWER POLE EM ELECTRIC METER TS TRAFFIC SIGNAL LP LIGHT POLE/STREET LIGHT EB ELECTRICAL BOX/TRANSFORMER FB FIBER OPTICS BOX/PEDESTAL TB TELEPHONE BOX/PEDESTAL TP TELEPHONE POLE CB CABLE/TELEVISION BOX AC AIR CONDITIONER UNIT CBU CLUSTER MAILBOX UNIT 12 ' S E T B A C K 12' SETBACK 12 ' S E T B A C K 10' SETBACK 65' ROW XXXXXXXXXXX X X X X X X X P P P E M StS( D ) StS( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) StS(D)StS(D)StS(D) StS(D) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) X X X X X X X X X X OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W(D)12" WATER LINE 12 " W A T E R L I N E 12 " S A N I T A R Y S E W E R 24 " S T O R M S E W E R 24" STORM SEWER 12 " S A N I T A R Y S E W E R SALVAGE PILE SALVAGE PILE SALVAGE PILE CP #550 BM #519 EXISTING INT RIM: 885.11 EXISTING MH RIM: 884.76 FL: 875.61 (N-S) CP #801 DIESEL FUEL TANKS LP TANK 10" I-BEAM 10" I-BEAM SALVAGE PILE SALVAGE PILE FENCELINE FENCELINE BARBWIRE EXISTING BUILDING EXISTING SHED CP #800 EXISTING APRON 6" PLASTIC FL: 882.48 (W) 100-YEAR FLOOD GRAVEL G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G(D)G(D)G(D) G(D)G(D)G(D) 1/2" IRON REBAR 1/2" IRON REBAR w/YELLOW PLASTIC CAP #11804 1/2" IRON REBAR w/YELLOW PLASTIC CAP #6586 1/2" IRON REBAR w/YELLOW PLASTIC CAP #6586 N0 0 ° 1 9 ' 1 3 " W 10 7 . 5 4 ' S0 0 ° 0 9 ' 4 8 " E 10 8 . 2 8 ' 402.63' N89°06'25"E 21 6 . 5 6 ' S0 0 ° 0 9 ' 4 8 " E 402.02' S89°19'06"W 21 5 . 0 7 ' N0 0 ° 1 9 ' 1 3 " W (1 0 8 . 9 ' ) (1 0 8 . 9 ' ) (1 0 8 . 9 ' ) S89°00'05"W 402.94' (S89°10'20"W 402.84') PARCEL B 86,825 SQUARE FEET (1.99 ACRES) N 0 GRAPHIC SCALE 40'20'60' Clapsaddle-Garber Associates, Inc 2413 Grand Avenue Des Moines, Iowa 50312 Ph 515-288-4823 www.cgaconsultants.com SHEET NO. DRAWN: CHECKED: DATE: DATE: APPROVED:DATE: PROJECT NO.DESIGNED:DATE:REVISIONNO.DATEBY DATEBYREVISIONNO. J: \ 2 4 - D A - 0 4 6 4 \ d w g s \ 5 _ S h e e t s \ 2 4 D A 0 4 6 4 - C . 1 1 0 ( E x i s t i n g C o n d ) . d w g - C . 1 1 0 - 0 2 - 1 4 - 2 5 - 1 1 : 5 0 a m - s p e t e r s CGA BELL SALVAGE SITE IMPROVEMENTS C.110 24-DA-0464 AMES, IOWA EXISTING CONDITIONS & DEMOLITION PLAN ---- ---- ---- -------- ---- ---- ---- GENERAL DEMOLITION NOTES: 1.ADJOINING PROPERTIES SHALL BE PROTECTED DURING DEMOLITION OPERATIONS. DEBRIS ON ADJOINING PROPERTIES SHALL BE CAREFULLY REMOVED BY CONTRACTOR. 2.ANY DAMAGE TO EXISTING PAVEMENT TO REMAIN DUE TO CONSTRUCTION ACTIVITIES SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE. ALL EFFORTS SHALL BE MADE TO NOT DISTURB EXISTING PAVEMENT TO REMAIN. 3.REMOVE ALL SIGNS, LIGHTS, POSTS, POLES, WALLS, AND ASSOCIATED FOUNDATIONS AS INDICATED. BACKFILL ALL HOLES AND DEPRESSIONS WITH SUITABLE SOIL. 4.CONTRACTOR SHALL SUPPLY DETAILED CONSTRUCTION SCHEDULE TO THE CITY. 5.ONE WEEK PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY: A. CITY OF AMES B. OWNER C. CLAPSADDLE-GARBER ASSOCIATES, INC. 6.CONTRACTOR SHALL DISPOSE OF PAVEMENT & FENCING OFF-SITE. 7.ALL CONSTRUCTION MATERIALS, DUMPSTERS, DETACHED TRAILERS, OR SIMILAR ITEMS ARE PROHIBITED ON PUBLIC STREETS OR WITHIN THE PUBLIC RIGHT-OF-WAY. KEY DEMOLITION CONSTRUCTION NOTES: REMOVE BUILDING & ALL EXISTING PAVING, CURBS, & BOLLARDS. COMPLETELY REMOVE EXISTING TREE/SHRUB & ROOTBALL. DISPOSE OF OFFSITE. BACKFILL DEPRESSIONS WITH SUITABLE SOIL. REMOVE & REPLACE EXISTING PAVEMENT/GRAVEL TO THE NEAREST JOINT LINE. PATCH SHALL BE BACKFILLED WITH ROCK FROM TOP OF SERVICE PIPES TO BOTTOM OF PAVEMENT. A B C A A C B B B B B B XXXXXXXXXXX X X X X X X X P P P E M StS( D ) StS( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) StS(D)StS(D)StS(D) StS(D) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) X X X X X X X X X X OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W(D)12" WATER LINE 12 " W A T E R L I N E 12 " S A N I T A R Y S E W E R 24 " S T O R M S E W E R 24" STORM SEWER 12 " S A N I T A R Y S E W E R SALVAGE PILE SALVAGE PILE SALVAGE PILE CP #550 BM #519 EXISTING INT RIM: 885.11 EXISTING MH RIM: 884.76 FL: 875.61 (N-S) CP #801 DIESEL FUEL TANKS LP TANK 10" I-BEAM 10" I-BEAM SALVAGE PILE SALVAGE PILE FENCELINE FENCELINE BARBWIRE CP #800 EXISTING APRON 6" PLASTIC FL: 882.48 (W) 100-YEAR FLOOD GRAVEL G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G(D)G(D)G(D) G(D)G(D)G(D) 1/2" IRON REBAR 1/2" IRON REBAR w/YELLOW PLASTIC CAP #11804 1/2" IRON REBAR w/YELLOW PLASTIC CAP #6586 1/2" IRON REBAR w/YELLOW PLASTIC CAP #6586 (1 0 8 . 9 ' ) (1 0 8 . 9 ' ) (1 0 8 . 9 ' ) (S89°10'20"W 402.84') PARCEL B 86,825 SQUARE FEET (1.99 ACRES) W W W W W W G G G G San San San San PROPOSED BUILDING PROPOSED SCALE 11.00'9.00' (TYP) R5.0 0 ' R15 . 0 0 ' R15 . 0 0 ' 18 . 0 0 ' 6. 0 0 ' 60 ' 70'5.00' 5. 0 0 ' 20.00' 15.00' 15 . 0 0 ' R15 . 0 0 ' R15.00' R44 . 0 0 ' R44 . 0 0 ' 30.00'30.00' 12 . 8 3 ' 11 . 0 0 ' 13 . 0 0 ' R15.00 ' R15 . 0 0 ' 15.00' 24 . 0 0 ' 5. 0 0 ' 37.00 15 . 5 0 ' 34 . 0 0 ' 45 . 0 0 ' 2.00' 34 . 0 0 ' 24 . 0 0 ' 16.00' 6. 0 0 ' N 0 GRAPHIC SCALE 40'20'60' Clapsaddle-Garber Associates, Inc 2413 Grand Avenue Des Moines, Iowa 50312 Ph 515-288-4823 www.cgaconsultants.com SHEET NO. DRAWN: CHECKED: DATE: DATE: APPROVED:DATE: PROJECT NO.DESIGNED:DATE:REVISIONNO.DATEBY DATEBYREVISIONNO. J: \ 2 4 - D A - 0 4 6 4 \ d w g s \ 5 _ S h e e t s \ 2 4 D A 0 4 6 4 - C . 2 0 0 ( S i t e P l a n ) . d w g - C . 2 0 0 - 0 2 - 1 4 - 2 5 - 1 1 : 5 0 a m - s p e t e r s CGA BELL SALVAGE SITE IMPROVEMENTS C.200 24-DA-0464 AMES, IOWA SITE PLAN ---- ---- ---- -------- ---- ---- ---- GENERAL LAYOUT NOTES: 1.ALL DIMENSIONS ARE TO BACK OF CURB UNLESS OTHERWISE NOTED. 2.ALL WORK SHALL BE IN ACCORDANCE WITH OSHA CODES & STANDARDS. NOTHING INDICATED ON THESE DRAWINGS SHALL RELIEVE THE CONTRACTOR FROM COMPLYING WITH APPROPRIATE SAFETY REGULATIONS. 3.SIGHT LIGHTING SHALL BE DETERMINED BY THE OWNER. 4.ALL DISTURBED AREAS SHALL BE SEEDED, FERTILIZED & MULCHED UNLESS OTHERWISE NOTED IN PLANS. REFER TO LANDSCAPING PLAN. 5.ANY DAMAGE TO THE PAVEMENT NOT SHOWN FOR REMOVAL ON THE PLANS DUE TO CONSTRUCTION ACTIVITIES SHALL BE REPAIRED AT THE CONTRACTORS EXPENSE. ALL EFFORTS SHALL BE MADE TO NOT DISTURB EXISTING PAVEMENT. 6.COORDINATE GAS, ELECTRIC, TELEPHONE, & FIBER OPTIC WITH RESPECTIVE UTILITY COMPANIES. 7.ALL CONSTRUCTION MATERIALS, DUMPSTERS, DETACHED TRAILERS, OR SIMILAR ITEMS ARE PROHIBITED ON PUBLIC STREETS OR WITHIN PUBLIC RIGHT-OF-WAY. CONSTRUCTION DETAILS INSTALL 6" PCC PAVEMENT INSTALL PCC SIDEWALK PAVEMENT INSTALL AGGREGATE INSTALL STRAIGHT CLASS A SIDEWALK INSTALL PARALLEL CURB RAMP FOR CLASS A SIDEWALK INSTALL MARKING INSTALL SINGLE-ACCESSIBLE PARKING SPACE INSTALL SANITARY SERVICE, C/O AT BUILDING CONNECTION AND EVERY 100 LF INSTALL CONCRETE CURB STOP BACKFILL MATERIAL (SEE C.501 FOR BACKFILL DETAIL) C.500 1 C.500 2 TRAFFIC CONTROL NOTES 1.ALL TRAFFIC CONTROL DEVICES & BARRIERS SHALL BE FURNISHED, ERECTED, MAINTAINED, & REMOVED BY THE CONTRACTOR. 2.PROPOSED CHANGES TO THE TRAFFIC CONTROL PLAN SHALL BE REVIEWED WITH THE ENGINEER BEFORE CHANGES ARE MADE. 3.ACCESS TO NEIGHBORING BUILDINGS SHALL BE MAINTAINED AT ALL TIMES. 4.ALL UTILITY WORK WITHIN THE PUBLIC R.O.W. SHALL CONFORM TO THE CITY OF AMES STANDARDS & THE CURRENT ADDITION OF THE MUTCD. 5.TWO-WAY TRAFFIC SHALL BE MAINTAINED AT ALL TIMES ALONG FREEL DRIVE. 6.THE CONTRACTOR SHALL USE CARE WHEN WORKING UNDER/OVER/AROUND ELECTRICAL LINES. 7.FLASHING OR STEADY BURN WARNING LIGHTS ARE REQUIRED ON TYPE II BARRICADES FOR OVERNIGHT CLOSURES. 8.WORK AREA MUST BE ENCLOSED WITH BARRICADES, FENCING, OR A COMBINATION OF THE TWO. CONSTRUCTION NOTES: INSTALL STOOP. SEE ARCHITECTURAL PLANS. INSTALL 4" DOMESTIC WATER SERVICE WITH CURB STOP, 4" WATER SERVICE WILL BE REDUCED TO A 2" WATER SERVICE AT THE BUILDING PRIOR TO THE METER CONNECTION. LIVE TAP 4" WATER SERVICE TO EXISTING 8" WATER MAIN PER CITY OF AMES SPECIFICATIONS. INSTALL 6" SANITARY SEWER SERVICE. SLOPE MUST BE 1% OR GREATER. C/O AT BUILDING CONNECTION AND EVERY 100 LF CONNECT 6" SANITARY SEWER SERVICE TO EXISTING 12" SANITARY SEWER MAIN PER CITY OF AMES SPECIFICATIONS. FIELD VERIFY FLOWLINE PRIOR TO ORDERING PIPE. CONNECT ELECTRIC SERVICE TO EXISTING POLE MOUNTED TRANSFORMER. COORDINATE WITH CITY OF AMES. COORDINATE GAS SERVICE CONNECTION WITH UTILITY COMPANY. A B C C.500 3 C.500 4 C.500 5 C.500 6 C.500 7 C.500 8 D E F G AA A B C D E C.500 1 C.500 1 C.500 1 C.500 2 C.500 2 C.500 3 C.500 3 C.500 3 C.500 4 C.500 5 C.500 7 C.500 6 C.500 6 C.500 8 G C.500 9 C.500 9 C.501 10C.501 10 5.00' C.500 1 C.500 2 5' FLARE 5' FLARE 5' FLARE 5' FLARESIDEWALK CROSSING XXXXXXX X X XXX X X X X P P P E M StS( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) StS(D)StS(D)StS(D)StS(D)StS(D)StS(D)StS(D)StS(D) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) X X X X X X X X XXX OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W( D ) W(D)W(D)W(D)W(D)W(D)W(D)12" WATER LINE 12 " W A T E R L I N E 12 " S A N I T A R Y S E W E R 24 " S T O R M S E W E R 24" STORM SEWER 12 " S A N I T A R Y S E W E R SALVAGE PILE SALVAGE PILE SALVAGE PILE CP #550 BM #519 EXISTING INT RIM: 885.11 EXISTING MH RIM: 884.76 FL: 875.61 (N-S)CP #801 DIESEL FUEL TANKS LP TANK 10" I-BEAM 10" I-BEAM SALVAGE PILE SALVAGE PILE FENCELINE FENCELINE BARBWIRE CP #800 EXISTING APRON 6" PLASTIC FL: 882.48 (W) 100-YEAR FLOOD 100-YEAR FLOOD GRAVEL G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G(D)G(D)G(D)G(D)G(D)G(D)G(D)G(D) G(D)G(D) 1/2" IRON REBAR 1/2" IRON REBAR w/YELLOW PLASTIC CAP #11804 1/2" IRON REBAR w/YELLOW PLASTIC CAP #6586 1/2" IRON REBAR w/YELLOW PLASTIC CAP #6586 (1 0 8 . 9 ' ) (1 0 8 . 9 ' ) (1 0 8 . 9 ' ) (1 0 8 . 9 ' ) (1 0 8 . 9 ' ) (S89°10'20"W 402.84') PARCEL B 86,825 SQUARE FEET (1.99 ACRES) W W W WGGG San San San PROPOSED BUILDING PROPOSED SCALE 11.00'9.00' (TYP) R5.0 0 ' R15 . 0 0 ' R15 . 0 0 ' 18 . 0 0 ' 6. 0 0 ' 60 ' 70'5.00' 5. 0 0 ' 20.00' 15.00' 15 . 0 0 ' R15 . 0 0 ' R15.00' R44 . 0 0 ' R44 . 0 0 ' 30.00'30.00' 12 . 8 3 ' 11 . 0 0 ' 13 . 0 0 ' R15.00 ' R15 . 0 0 ' 15.00' 24 . 0 0 ' 5. 0 0 ' 37.00 15 . 5 0 ' 34 . 0 0 ' 45 . 0 0 ' 2.00' 34 . 0 0 ' 24 . 0 0 ' 16.00' 6. 0 0 ' N 0 GRAPHIC SCALE 60'30'90' Clapsaddle-Garber Associates, Inc 2413 Grand Avenue Des Moines, Iowa 50312 Ph 515-288-4823 www.cgaconsultants.com SHEET NO. DRAWN: CHECKED: DATE: DATE: APPROVED:DATE: PROJECT NO.DESIGNED:DATE:REVISIONNO.DATEBY DATEBYREVISIONNO. J: \ 2 4 - D A - 0 4 6 4 \ d w g s \ 5 _ S h e e t s \ 2 4 D A 0 4 6 4 - C . 2 0 0 ( S i t e P l a n ) . d w g - C . 2 0 1 - 0 2 - 1 4 - 2 5 - 1 1 : 5 0 a m - s p e t e r s CGA BELL SALVAGE SITE IMPROVEMENTS C.201 24-DA-0464 AMES, IOWA OVERALL SITE LAYOUT ---- ---- ---- -------- ---- ---- ---- FIRE CODE 1.EXISTING TIRE STORAGE YARDS SHALL BE PROVIDED WITH FIRE APPARATUS ACCESS ROADS IN ACCORDANCE WITH THE INTERNATIONAL FIRE CODE SECTIONS 1106.1.1 AND 1106.2.2 2.SALVAGE PILES SHALL NOT EXCEED 20 FEET IN HEIGHT. 3.OUTDOOR STORAGE WITHIN THE UTILITY EASEMENT UNDERNEATH HIGH VOLTAGE TRANSMISSION LINES SHALL BE LIMITED TO NONCOMBUSTIBLE MATERIAL. STORAGE OF HAZARDOUS MATERIAL IN PROHIBITED. 4.GATEWAYS SHALL BE KEPT CLEAR OF OBSTRUCTION AND BE FULLY ACCESSIBLE AT ALL TIMES. 5.NEW TIRE STORAGE YARDS SHALL BE PROVIDED WITH FIRE APPARATUS ACCESS ROADS N ACCORDANCE WITH SECTION 503 AND SECTION 3406.2. EXISTING TIRE STORAGE YARDS SHALL BE PROVIDED WITH FIRE APPARATUS ACCESS ROADS WHERE REQUIRED IN CHAPTER 11. 6.OUTSIDE STORAGE OF COMBUSTIBLE MATERIAL SHALL NOT BE LOCATED WITHIN 10 FEET OF A LOT LINE WITH THE FOLLOWING EXCEPTION. 6.1.THE SEPARATION DISTANCE MAY BE REDUCED TO 3 FEET FOR STORAGE NOT EXCEEDING 6 FEET OF HEIGHT. 7.STRUCTURES SHALL NOT BE CONSTRUCTED WITHIN THE UTILITY EASEMENT BENEATH HIGH VOLTAGE TRANSMISSION LINES. 8.STORAGE BENEATH OVERHEAD PROJECTIONS FROM BUILDINGS. WHERE BUILDINGS ARE PROTECTED BY AUTOMATED SPRINKLERS, THE OUTDOOR STORAGE, DISPLAY AND HANDLING OF COMBUSTIBLE MATERIALS UNDER EAVES, CANOPIES OR OTHER PROJECTIONS OR OVERHANGS ARE PROHIBITED EXCEPT WHERE AUTOMATED SPRINKLERS ARE PRESENT. 9.IF BULK VOLUME OF STORED MATERIAL IS MORE THAN 20,000 CUBIC FEET, A FIRMLY ANCHORED FENCE OR OTHER APPROVED METHOD OF SECURITY THAT CONTROLS UNAUTHORIZED ACCESS TO THE STORAGE YARD SHALL SURROUND THE STORAGE YARD. 10.00' EXISTING SALVAGE PILES TO BE CUT BACK 10' FROM THE PROPERTY LINE, ANY EXCESS SALVAGE SHALL BE DISTRIBUTED TO OTHER LOCATIONS OPEN SPACE 10.00' XXXXXXXXXXX X X X X X X X P P P E M X X X X X X X X X X OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G(D)G(D)G(D) G(D)G(D)G(D) 1/2" IRON REBAR 1/2" IRON REBAR w/YELLOW PLASTIC CAP #11804 1/2" IRON REBAR w/YELLOW PLASTIC CAP #6586 1/2" IRON REBAR w/YELLOW PLASTIC CAP #6586 (1 0 8 . 9 ' ) (1 0 8 . 9 ' ) (1 0 8 . 9 ' ) (S89°10'20"W 402.84') PARCEL B 86,825 SQUARE FEET (1.99 ACRES) G G G G 886887 88 8 88 8 886 887 88 8 888 88 8 889 PROPOSED SCALE 888 . 1 1 888.20 888.18 888 . 3 8 888.38 888.36 888 . 8 8 888.30 887 . 9 9 887 . 2 2 887.66 888 . 3 9 888 . 9 0 888.48 888.90 888.90888.50 885 . 3 1 885 . 5 9 886 . 5 2 887 . 2 9 887 . 5 6 887 . 7 9 888 . 6 0 888 . 9 0 888.90888.90 888.90 887 . 6 7 ??? 887 . 7 2 888 . 1 5 888 . 2 4 887 . 9 8 887 . 5 2 887 . 0 5 887 . 0 0 887 . 0 0 886 . 7 0 886 . 8 0 889.00 889.00 887 . 3 9 887 . 3 9 889.00 889.00 887 . 2 0 887 . 2 0 PROPOSED BUILDING FFE: 889.00 886 . 7 5 884 . 9 9 885 . 0 9 4. 0 % 1. 0 % 0.8% 0.5% 1. 5 % 2. 0 % 2. 0 % 18 . 1 % 2.0%2.0% 3.0% 2.0% 8. 1 % 0. 6 % 1.7%1.6% 3. 4 % 3.9% 0. 3 % 6.0%5.4% 0.1%0.0% 1. 0 % 2. 0 % 0. 9 % 4. 7 % 0. 2 % 3.0%1.2% 4.2% 1.3% 1.2% 2.3% 1.4% 4.5% 6. 0 % 2.2 % 1.3% 885 . 7 8 886 . 5 4 888.32 888.20 887.93 887 . 8 9 1. 5 % 885. 4 9 885 . 4 9 88 5 888 2.6%2.6%2.4%4.5%4.4% 888.50 884 . 6 0 885 . 0 6 885 . 1 3 885 . 4 4 88 7 N 0 GRAPHIC SCALE 40'20'60' Clapsaddle-Garber Associates, Inc 2413 Grand Avenue Des Moines, Iowa 50312 Ph 515-288-4823 www.cgaconsultants.com SHEET NO. DRAWN: CHECKED: DATE: DATE: APPROVED:DATE: PROJECT NO.DESIGNED:DATE:REVISIONNO.DATEBY DATEBYREVISIONNO. J: \ 2 4 - D A - 0 4 6 4 \ d w g s \ 5 _ S h e e t s \ 2 4 D A 0 4 6 4 - C . 3 0 0 ( G r a d i n g P l a n ) . d w g - C . 3 0 0 - 0 2 - 1 4 - 2 5 - 1 1 : 5 1 a m - s p e t e r s CGA BELL SALVAGE SITE IMPROVEMENTS C.300 24-DA-0464 AMES, IOWA GRADING PLAN ---- ---- ---- -------- ---- ---- ---- LEGEND TOC TOP OF CURB HP HIGH POINT LP LOW POINT T/W TOP OF WALL B/W BOTTOM OF WALL 2.0%PROPOSED SLOPE PROPOSED DRAINAGE PATTERN GENERAL GRADING NOTES 1.SLOPES SHALL NOT BE GREATER THAN 3:1 2.GRADE TO DRAIN AWAY FROM ALL BUILDINGS. 3.SIDEWALK CROSS SLOPES SHALL NOT EXCEED 2%. CONTRACTOR SHALL TARGET 1.5% CROSS SLOPE. 4.STRIP TOPSOIL TO WHATEVER DEPTHS ARE ENCOUNTERED (A MINIMUM OF 6") & STOCKPILE AS PER PLAN. RESPREAD TOPSOIL AT LEAST 8" DEEP AS PER SPECIFICATIONS. 5.GEOTECHNICAL REPORT IS AVAILABLE UPON REQUEST. AREA OF DISTURBANCE 0.95 ACRES XXXXXXX X X X X X X X P P P E M St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) St S ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) Sa n ( D ) X X X X X X X X X OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E 12 " S A N I T A R Y S E W E R 24 " S T O R M S E W E R 12 " S A N I T A R Y S E W E R CP #801 DIESEL FUEL TANKS LP TANK 10" I-BEAM 10" I-BEAMSALVAGE PILE CP #800 G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) G( D ) 1/2" IRON REBAR w/YELLOW PLASTIC CAP #6586 w/YELLOW PLASTIC CAP #6586 (S89°10'20"W 402.84') W W W W W G G G G San San San San PROPOSED BUILDING 30.00' N 0 GRAPHIC SCALE 40'20'60' Clapsaddle-Garber Associates, Inc 2413 Grand Avenue Des Moines, Iowa 50312 Ph 515-288-4823 www.cgaconsultants.com SHEET NO. DRAWN: CHECKED: DATE: DATE: APPROVED:DATE: PROJECT NO.DESIGNED:DATE:REVISIONNO.DATEBY DATEBYREVISIONNO. J: \ 2 4 - D A - 0 4 6 4 \ d w g s \ 5 _ S h e e t s \ 2 4 D A 0 4 6 4 - C . 4 0 0 ( L a n d s c a p e P l a n ) . d w g - C . 4 0 0 - 0 2 - 1 4 - 2 5 - 1 1 : 5 1 a m - s p e t e r s CGA BELL SALVAGE SITE IMPROVEMENTS C.400 24-DA-0464 AMES, IOWA LANDSCAPE PLAN ---- ---- ---- -------- ---- ---- ---- LANDSCAPE NOTES: 1.PLANT QUANTITIES ARE FOR INFORMATION ONLY; DRAWING SHALL PREVAIL IF CONFLICT OCCURS. CONTRACTOR IS RESPONSIBLE FOR CALCULATING OWN QUANTITIES AND BASING BID ACCORDINGLY. 2.CONTRACTOR SHALL PLACE SHREDDED HARDWOOD BARK MULCH AROUND ALL TREES AND IN SPECIFIED PLANTING BEDS (SEE LANDSCAPE CONSTRUCTION NOTES) TO A DEPTH OF 3". WALNUT PRODUCTS ARE PROHIBITED. 3.KIND, SIZE, AND QUALITY OF PLANT MATERIAL SHALL CONFORM TO AMERICAN STANDARD FOR NURSERY STOCK, ANSI 260-2004, OR MOST RECENT EDITION. 4.THE CONTRACTOR SHALL REPORT SUBSURFACE SOIL OR DRAINAGE PROBLEMS TO THE ENGINEER. 5.THE CONTRACTOR SHALL SHOW PROOF OF PROCUREMENT, SOURCES, QUANTITIES AND VARIETIES FOR ALL SHRUBS, PERENNIALS, ORNAMENTAL GRASSES WITHIN 21 DAYS FOLLOWING THE AWARD OF CONTRACT. TIMELY PROCUREMENT OF ALL PLANT MATERIAL IS ESSENTIAL TO THE SUCCESSFUL COMPLETION AND INITIAL ACCEPTANCE OF THE PROJECT. 6.SUBSTITUTIONS SHALL ONLY BE ALLOWED WHEN THE CONTRACTOR HAS EXHAUSTED ALL SOURCES FOR THE SPECIFIED MATERIAL, AND HAS PROVEN THAT THE SPECIFIED MATERIAL IS NOT AVAILABLE. THE CONTRACTOR MUST PROVIDE NAME AND VARIETY OF SUBSTITUTION TO THE ENGINEER FOR APPROVAL PRIOR TO TAGGING OR PLANTING. SUBSTITUTIONS SHALL BE NEAREST EQUIVALENT SIZE OF VARIETY OF PLANT HAVING SAME ESSENTIAL CHARACTERISTICS. 7.ALL PLANT MATERIAL SHALL BE NURSERY GROWN, SOUND, HEALTHY, VIGOROUS AND FREE FROM INSECTS, DISEASE AND INJURIES, WITH HABIT OF GROWTH THAT IS NORMAL FOR THE SPECIES. SIZES SHALL BE EQUAL TO OR EXCEEDING SIZES INDICATED ON THE PLANT SCHEDULE. THE CONTRACTOR SHALL SUPPLY PLANTS IN QUANTITY AS SHOWN ON DRAWINGS. 8.STAKE OR PLACE ALL PLANTS IN FIELD AS INDICATED ON THE DRAWINGS OR AS DIRECTED BY THE ENGINEER FOR APPROVAL BY THE OWNER PRIOR TO PLANTING. REMOVE STAKING AT END OF WARRANTY PERIOD. 9.ALL DISTURBED AREAS NOT OTHERWISE COVERED BY BUILDING, PAVEMENT, AND LANDSCAPE BEDS SHALL BE SEEDED WITH TYPE 3 GRASS OR OTHER SURFACING MATERIAL AS APPROVED BY THE OWNER. 10.CONTRACTOR SHALL PLACE TOPSOIL FROM THE SITE OR SOIL CONDITIONED OR TILLED INTO THE TOP 6 INCHES WITH AT LEAST A 5% ORGANIC CONTENT, INTO REQUIRED PLANTING AREAS (YARD AREAS, BUFFER YARDS, OR PLANTERS). 11.STOCKPILED TOPSOIL SHOULD BE PLIABLE LOAM, SECURE FROM NATURALLY WELL-DRAINED AREAS, FREE OF ADMIXTURE OF SUBSOIL, FREE FROM CLAY LUMPS + STONE AND OTHER DEBRIS OVER 1 INCH IN DIAMETER. (PER IOWA DOT SPEC. SP-155079) 12.TOPSOIL SHALL HAVE A PH VALUE OF MINIMUM 5.5 AND MAXIMUM OF 7.0. (PER IOWA DOT SPEC. SP-155079) 13.CONTRACTOR IS RESPONSIBLE FOR TESTING TOPSOIL AND SUBMITTING TEST RESULTS TO ENGINEER FOR REVIEW AND APPROVAL PRIOR TO USE AND PLACEMENT. (PER IOWA DOT SPEC. SP-155079) SITE INFORMATION: TOTAL SITE AREA = 86,825 SF(1.99 AC) TOTAL OPEN SPACE AREA(GRASS AND PLANTING BEDS) (15% (13,155 SF REQUIRED)) = 13,329.8 SF(15.35%) TOTAL IMPERVIOUS AREA = 18,661 SF PARKING LOT PAVED AREA = 11,348 SF PROPOSED BUILDING AREA = 4,199 SF PARKING LOT LANDSCAPING AREA = 1,174.7 SF PLANT SCHEDULE KEY BOTANICAL NAME COMMON NAME QTY.SIZE Deciduous Overstory Trees OV Ostrya virginiana Autumn Treasure Hophornbeam 2 (38' H & 20' W)1.5" B&B GB Ginkgo biloba 'Princeton Sentry'Princeton Sentry Ginkgo 3 (50' H & 25' W)1.5" B&B Ornamental Understory Trees AG Amelanchier x grandiflora 'Autumn Brilliance' Autumn Brilliance Serviceberry(Tree Form)3 (25' H & 25' W)1.5" B&B CM Cornus mas 'Golden Glory'Golden Glory Dogwood 3 (25 H & 15')1.5" B&B Shrubs TO Thuja occidentalis 'Bailjohn'Technito Arborvitae 14 (10' H & 5' W)#5 CNT TM Taxus x media Stonehenge Dark Druid 22 (4' H & 3' W)#5 CNT IG Ilex glabra Shamrock Inkerry 16 (5' H & 5' W)#5 CNT Perennials & Grasses PV Panicum virgatum 'Shenandoah'Shenandoah Switch Grass 26 (4' H & 3' W)#1 CNT SN Sorghastrum nutans Indian Grass 26 (8' H & 3' W)#1 CNT PA Pennisetum alopecuroides ' Hameln'Dwarf Fountain Grass 26 (3' H & 2' W)#1 CNT Groundcover EF Euonymus fortunei 'Coloratus'Purpleleaf Wintercreeper 2,194 SF (2' H & 8' W)FLAT (24-3") FRONT YARD LANDSCAPING REQUIREMENTS #ZONING DESCRIPTION REQUIRED PROPOSED 1 Landscape Front Yard for Parking Lots shall be Minimum 10' and Landscape Front Yard for Buildings Shall Conform to Dimensional Setback of Base Zone(10') Between Street and Front Yard(8 Shrubs and 12 Grasses per 1,000 SF of Front Yard Area) Freel Dr(52 Shrubs and 78 Grasses(6,495.22 SF))52 Shrubs and 78 Grasses 2 1 Overstory Tree Every 50 Lineal Feet of Street Frontage 217 LF=5 Trees 6 Trees to Meet 50% of 1 Species Rule PARKING LOT LANDSCAPING #ZONING DESCRIPTION REQUIRED PROPOSED 1 10% of Total Gross Parking Lot Area(11,348)(Not Including Driveway in Front Yard) 10%=1,135 SF 10.35%=1,174.7 SF 2 1 Overstory Tree Every 200 SF of the 10%( SF) Landscaped Area 5 Trees 5 Trees 1 OV 1 OV 1 GB 26 SN 13 PV 1 CM LANDSCAPE CONSTRUCTION NOTES: TYPE 3 (PERMANENT WARM-SEASON SLOPE AND DITCH MIXTURE) ORGANIC MULCH NO-DIG PLASTIC EDGING TO BE INSTALLED AROUND SPECIFIED PLANTING BEDS FRONT YARD CALCULATED AREA(SEE ATTACHED EXHIBIT) GROUNDCOVER PLANT PURPLELEAF WINTERCREEPER(SEE PLANT SCHEDULE) A C B A A A CB 1 GB CB CB D A 1 CM 1 AG 1 AG 1 AG E CBCB CB E EE 1 GB E 13 PV 1 CM 8 TO 6 TO 12 PA 13 TM 8 IG 8 IG 14 PA CB 9 TM D D D Clapsaddle-Garber Associates, Inc 2413 Grand Avenue Des Moines, Iowa 50312 Ph 515-288-4823 www.cgaconsultants.com SHEET NO. DRAWN: CHECKED: DATE: DATE: APPROVED:DATE: PROJECT NO.DESIGNED:DATE:REVISIONNO.DATEBY DATEBYREVISIONNO. J: \ 2 4 - D A - 0 4 6 4 \ d w g s \ 5 _ S h e e t s \ 2 4 D A 0 4 6 4 - C . 5 0 0 ( D e t a i l s ) . d w g - C . 5 0 0 - 0 2 - 1 4 - 2 5 - 1 1 : 5 1 a m - s p e t e r s CGA BELL SALVAGE SITE IMPROVEMENTS C.500 24-DA-0464 AMES, IOWA DETAILS ---- ---- ---- -------- ---- ---- ---- SLOPE AS PER PLANS 6" PCC PAVEMENT 4" GRANULAR SUBBASE (MINIMUM) TOP 12" OF SUBGRADE SHALL BE COMPACTED TO 95% STANDARD PROCTOR DENSITY (SPD) 2.0' BEYOND EDGE OF PAVEMENT PCC PAVEMENT SECTION1 4" PCC PAVEMENT 4" GRANULAR SUBBASE (MINIMUM) SLOPE AS PER PLANS TOP 12" OF SUBGRADE SHALL BE COMPACTED TO 95% STANDARD PROCTOR DENSITY (SPD) 2.0' BEYOND EDGE OF PAVEMENT PCC SIDEWALK PAVEMENT SECTION2 8" GRANULAR BASE (MINIMUM) SLOPE AS PER PLANS TOP 12" OF SUBGRADE SHALL BE COMPACTED TO 95% STANDARD PROCTOR DENSITY (SPD) 2.0' BEYOND EDGE OF PAVEMENT AGGREGATE SECTION3 ADJACENT PAVEMENT 2.0% MAX. 12"18" SIDEWALK4" MIN. 6" SEALED 'E' JOINT 1" RADIUS STRAIGHT FACED CLASS A SIDEWALK4 KEY TURNING SPACE 2 1 2 PARALLEL CURB RAMP (FOR CLASS A SIDEWALK) CURB RAMP 1 PARALLEL CURB RAMP: TARGET CROSS SLOPE OF 1.5% WITH A MAXIMUM CROSS SLOPE OF 2.0%. THE LENGTH OF THE PARALLEL RAMP IS NOT REQUIRED TO EXCEED 15 FEET, REGARDLESS OF RESULTING SLOPE. DO NOT EXCEED 8.3% SLOPE FOR PARALLEL RAMPS SHORTER THAN 15 FEET. TURNING SPACE: TARGET SLOPE OF 1.5%, WITH A MAXIMUM SLOPE PERPENDICULAR TO THE TRAVEL DIRECTIONS OF 2.0%. AT MID-BLOCK CROSSINGS, CROSS SLOPE OF LANDING MAY EXCEED 2.0% TO MATCH ROADWAY GRADE. MINIMUM 4 FEET BY 4 FEET. W 4.0' M I N PARALLEL CURB RAMP FOR CLASS A SIDEWALK5 BU I L D I N G 45° 1' PARKING STALLS 4" (TYPICAL) 4" (TYP) NOTES: 1. PAVEMENT MARKINGS (STRIPING) SHALL BE MADE WITH TRAFFIC PAINT OR PERMANENT TAPE. 2. MEASUREMENTS IN PLANS ARE TO CENTER OF MARKING WIDTH. SE E P L A N S F O R L E N G T H SEE PLANS FOR WIDTH SEE PLANS FOR WIDTH 11' MIN 5' MIN 4" WIDE LINES FU L L L E N G T H O F PA R K I N G S P A C E ACCESSIBLE ROUTE 36° TYP 36° 3' 4' ANGLE ORIENTATION FOR FIELD LAYOUT CURB RAMP (SHALL NOT EXTEND INTO THE ACCESS AISLE) SIGN R7-8 5' ABOVE PARKING SURFACE SIGN R7-8P ACCESS AISLE 2' TYP PAVEMENT MARKING REQUIRED DETECTABLE WARNING SURFACE REQUIRED IF CURB RAMP IS LOCATED WITHIN PUBLIC RIGHT-OF-WAY MARKING DETAIL6 SINGLE-ACCESSIBLE PARKING SPACE7 6'-0" 6"6" 11 " 5 12" 1" DIA. HOLE FOR 3 4" X 30" LG. STEEL ANCHOR - 2 PER BUMPER PLAN 3'-0" CL 3"4" 4" 10"8"10"11" ELEVATION SECTION 2" 3" 4" 2 12"2 12"6" 7 12" MIN. REINF. 2-#5 X 5'-6" CONCRETE WHEEL STOP9 Clapsaddle-Garber Associates, Inc 2413 Grand Avenue Des Moines, Iowa 50312 Ph 515-288-4823 www.cgaconsultants.com SHEET NO. DRAWN: CHECKED: DATE: DATE: APPROVED:DATE: PROJECT NO.DESIGNED:DATE:REVISIONNO.DATEBY DATEBYREVISIONNO. J: \ 2 4 - D A - 0 4 6 4 \ d w g s \ 5 _ S h e e t s \ 2 4 D A 0 4 6 4 - C . 5 0 0 ( D e t a i l s ) . d w g - C . 5 0 1 - 0 2 - 1 4 - 2 5 - 1 1 : 5 1 a m - s p e t e r s CGA BELL SALVAGE SITE IMPROVEMENTS C.501 24-DA-0464 AMES, IOWA DETAILS (CONT) ---- ---- ---- -------- ---- ---- ---- KEY PIPE BEDDING HAUNCH SUPPORT PRIMARY BACKFILL FINAL TRENCH BACKFILL BURY DEPTH SECONDARY BACKFILL BACKFILL NOTES: REFER TO SUDAS SPECIFICATIONS MANUAL SECTION 3010 FOR PLACEMENT REQUIREMENTS. PIPE BEDDING SHALL CONSIST OF CLASS 1 GRANULAR MATERIAL HAUNCH SUPPORT SHALL CONSIST OF CLASS 1 GRANULAR MATERIAL PRIMARY AND SECONDARY BACKFILL SHALL CONSIST OF CLASS 3 OR 4A BACKFILL MATERIAL AND SHALL BE COMPACTED TO AT LEAST 95% COMPACTION OF STANDARD PROCTOR DENSITY. FINAL TRENCH BACKFILL SHALL CONSIST OF CLASS 3 OR 4A BACKFILL MATERIAL. FINAL TRENCH MATERIAL SHALL BE COMPACTED TO AT LEAST 95% OF STANDARD PROCTOR DENSITY WITHIN THE RIGHT OF WAY OD D TW d = OUTSIDE DIAMETER OF PIPE = INSIDE DIAMETER OF PIPE = TRENCH WIDTH AT TOP OF PIPE = DEPTH OF BEDDING MATERIAL BELOW PIPE OD/2 OD/2 TW OD SPRINGLINE OF PIPE OD/6 d D 12'' MIN TRENCH BEDDING & BACKFILL FOR SERVICE LINES10 NOTE: IN AREAS TO REMAIN UNPAVED, TERMINATE BACKFILL MATERIAL 8" BELOW FINISHED GRADE. USE TOPSOIL FOR THE FINAL 8" ABOVE TRENCH BACKFILL MATERIAL. COMPLY WITH SPECIFICATIONS FOUND IN SUDAS SECTION 3010 (DIMENSIONS ARE NOMINAL) 1 PLUG CLEANOUT CASTINGSEWER MAIN 7/8'' 9 7/8'' 6''9'' 7/8''15 5 8'' 45° BEND WYE 3 2 1 4'' MIN 1 4 2'' MIN CASTING CAP 2 #4 BAR (TYP.) 20'' MIN CONCRETE PAD 6'' PVC RISER STANDARD DUTY CASTING COMPLYING WITH AASHTO M 306. MARK LID WITH ''SANITARY'' OR ''SANITARY C.O.'' DO NOT ALLOW CASTING TO BEAR ON TOP OF RISER PIPE. 6-INCH PVC SERVICE PIPE THREADED PVC CAP OR IRON BODY FERRULE WITH BRASS SCREW PLUG 3 4 SANITARY SEWER CLEANOUT8.1 10' 10' to 12' ROW LINE LOCATION POST 22.5° TO 45° SERVICE LINE SLOPE SERVICE LINE SLOPE: 4 INCH: 2% TO 5% 6 INCH AND GREATER: 1% TO 5% UNDISTURBED EARTH WHEN REPLACING SERVICE STUB ONLY. CLASS 1 BEDDING MATERIAL WHEN REPLACING MAIN & SERVICE STUB 1 2 TEE OR WYE SANITARY SEWER MAIN SANITARY SEWER SERVICE STUB8 SUBGRADE MATCH PAVEMENT TO EXISTING THICKNESS AND TYPE EXISTING PAVEMENT EXISTING GRANULAR SUBBASE CLEAN 1/2"-1" ROCK, CONSOLIDATED 3 3 SIEVE 1 1/2" 1" 1/2" No. 4 No 8 PERCENT PASSING 100 95 TO 100 25 TO 60 0 TO 10 0 TO 5UNDISTURBED EARTH 2 CLASS 1 BEDDING MATERIAL CAP, PLUG, OR CONNECTION TO EXISTING SERVICE LINE WITH WATERTIGHT CONNECTION 1 4 4 CLEAN 1/2"-1" ROCK TO SIT A MINIMUM OF 6 MONTHS PRIOR TO PAVEMENT INSTALLATION. PAVING MAY BE INSTALLED WHEN THE FORECASTED TEMPERATURES REMAIN ABOVE 38° F FOR THE NEXT 5 DAYS.