HomeMy WebLinkAboutA002 - Staff Report dated November 14, 2012 ITEM #: 5
CITY OF AMES DATE: 11/14/12
DEPARTMENT OF PLANNING AND HOUSING
REPORT TO THE ZONING BOARD OF ADJUSTMENT
DATE PREPARED: November 9, 2012
MEETING DATE: November 14, 2012
REQUEST FOR A CONDITIONAL USE PERMIT TO ALLOW AN ALTERNATIVE
METHOD OF ELEVATION IN THE FLOODWAY FRINGE: To allow the reconstruction
of a multi-family apartment at 301 S. 5th Street.
PROPERTY OWNER: South Meadows Housing Cooperative
APPLICANT: Chuck Winkleblack
LOCATION: 301 S. 5th Street
ZONING: High Density Residential
PROJECT DESCRIPTION: The multi-family structure at 301 S. 5th Street was heavily
damaged by fire in July, 2012. The damage exceeded 50 percent of the value of the
structure, thus requiring that any repair or reconstruction be done to meet the current
flood plain regulations. The Ames Municipal Code requires that residential structures be
elevated to three feet above the base flood elevation (the water surface level of a flood
having a 1 percent annual chance of occurrence, otherwise known as the 100-year
flood). The flood plain regulations also require that the elevation extend 18 feet beyond
the perimeter of the structure.
The owner proposes to reconstruct the apartment (see the accompanying staff report
regarding the Special Use Permit) and to reuse the existing foundation and ground level
parking structure. Since the ground level parking is within the walls of the structure, it is
not possible to place fill 18 feet around the perimeter of the building to meet the
requirements without impacting the existing parking arrangement.
APPLICABLE LAW: A
The laws applicable to this case are as follows:
Chapter 9, Section 9.1(2) of the Ames Municipal Code states:
It is the purpose of this ordinance to promote the public health, safety, and
general welfare by minimizing those flood losses described in Section 9.1(2) with
provisions designed to:
(a) Reserve sufficient floodplain area for the conveyance of flood flows so that
flood heights and velocities will not be increased by greater than one (1)
foot.
(b) Restrict or prohibit uses which are dangerous to health, safety, or property
in times of flood or which cause excessive increases in flood heights or
velocities.
(c) Require that uses vulnerable to floods, including public utilities, which
serve such uses, be protected against flood damage at the time of initial
construction or substantial improvement.
(d) Protect individuals from buying lands, which are unsuited for intended
purposes because of flood hazard.
(e) Assure that eligibility is maintained for property owners in the community
to purchase flood insurance through the National Flood Insurance
Program.
Chapter 9, Section 9.5 of the Ames Municipal Code states:
Section 9.5 Floodway Fringe Overlay District
(2) Performance Standards. All uses must be consistent with the need to minimize
flood damage and shall meet the following applicable performance standards.
(a) All structures shall
(i) be adequately anchored to prevent flotation, collapse or lateral
movement of the structure,
(ii) be constructed with materials and utility equipment resistant to flood
damage, and
(iii) be constructed by methods and practices that minimize flood damage.
(b) Residential buildings. All new or substantially improved residential structures
shall have the lowest floor, including basements, elevated a minimum of three (3)
feet above the base flood elevation level. Construction shall be upon
compacted fill which shall, at all points, be no lower than three (3) feet
above the base flood elevation level and extend at such elevation at least
18 feet beyond the limits of any structure erected thereon. Alternate methods
of elevating (such as piers) may be allowed, subject to favorable consideration by
the Zoning Board of Adjustment and issuance of a Conditional Use Permit, where
existing topography, street grades, or other factors preclude elevating by fill. In
such cases, the methods used must be adequate to support the structure as well
as withstand the various forces and hazards associated with flooding. All new
residential buildings shall be provided with a means of access which will be
passable by wheeled vehicles during the base flood elevation.
2
and
Section 9.5 (2)(k)(ii):
New and substantially improved structures must be designed (or modified) and
adequately anchored to prevent flotation, collapse, or lateral movement of the
structure resulting from hydrodynamic and hydrostatic loads, including the effects
of buoyancy.
Chapter 9, Section 9.7 of the Ames Municipal Code states:
a. Factors upon which the decision of the Board shall be based. In passing
upon requests for Conditional Uses or Variances, the Zoning Board shall
consider all relevant factors specified in other sections of the ordinance and:
(1) The danger to life and property due to increased flood heights or velocities
caused by encroachments.
(2) The danger that materials may be swept onto other lands or down stream
to the injury of others.
(3) The proposed water supply and sanitation systems and the ability of these
systems to prevent disease, contamination, and unsanitary conditions.
(4) The susceptibility of the proposed facility and its contents to flood damage
and the effect of such damage to the individual owner.
(5) The importance of the services provided by the proposed facility to the
community.
(6) The requirements of the facility for a flood plain location.
(7) The availability of alternative locations not subject to flooding for the
proposed use.
(8) The compatibility of the proposed use with existing development and
development anticipated in the foreseeable future.
(9) The relationship of the proposed use to the comprehensive plan and flood
plain management program for the area.
(10) The safety of access to the property in times of flood for ordinary and
emergency vehicles.
(11) The expected heights, velocity, duration, rate of rise, and sediment
transport of floodwater expected at the site.
3
(12) Such other factors which are relevant to the purpose of the ordinance.
FINDINGS OF FACTS & CONCLUSIONS:
Staff makes the following findings of facts:
1. The design of the structure predates the adoption of the City's flood plain
regulations in 1980.
2. The finished floor of the existing structure meets the elevation requirements
of 3 feet above base flood elevation.
3. The open garages under the structure are not elevated. However, the flood
plain regulations (Section 9.5(2)(k)) allow parking areas and other "low
damage potential storage" if the walls have sufficient openings to allow the free
entry and exit of rising flood waters. The garages will not have doors.
4. All mechanical and electrical equipment
e ill be ion or higher.
h gh oved from the lower level
and raised to 3 feet above the base
S. All outdoor condenser units will be raised to 3 feet above base flood
elevation by mounting on the exterior walls of the structure.
6. The entryways to the building are, themselves, below the elevation
requirements. However, construction techniques will be of low damage
potential. The lowest floor of the habitable space meets the elevation
requirements.
7. The parking spaces under the structure preclude the ability to elevate to 18
feet around the perimeter of the structure.
8. Because of the design of the structure, the apartments have survived
several flood events with only minimal damage. None of the previous flood
damage rose to the level that required
didldamagethe structure nce with ewel�beyond
d plain
regulations. However, the July 2
the 50 percent threshold.
9. The perimeter elevation requirements for a residential structure are intended
to provide a safe evacuation area in the event of a flood event, allowing the
residents to escape the structure but remain dry while awaiting rescue. In this
neighborhood, however, neither S. 5'" Street itself, the driveways of all the
apartments along S. 5t" Street, or most of the apartment buildings themselves
t"
are elevated to the base flood level. The water level over S. 5Street is
estimated to be approximately 3 and one-half feet deep in a base flood event.
During past major flooding events, unconventional methods such as front end
loaders and boats have been needed to evacuatepeople
alorom theng the S street.
t Street
apartments by navigating through turbulent flood ong
4
10. The requirement that the reconstructed building provide the perimeter
elevation would result in the loss of 32 parking spaces under the building. It
would also require the reconstruction of driveways that would interfere with the
approved parking arrangements on the buildings to the west and east. It would
also likely require driveways that are very steep as they approach S. 51h Street.
11. As an alternative to the perimeter elevation requirements, the owner
proposes that the existing elevated garage be allowed to provide the
necessary elevation. The garages place the finished floor of the structure at
more than 3 feet above the base flood elevation.
CONCLUSIONS:
Access to the site in the event of a flood event is difficult for all the structures along S.
5th Street due to the elevation of the road. Both driveways and many of the apartment
buildings themselves are also below the base flood elevation. The relief requested from
the 18 foot distance requirement would not increase the risk that already exists. For
there to be an effective means of accessing the site during flooding, S. 5th Street, itself,
would need to be elevated.
After an examination of the submitted plans and an evaluation of those plans as they
pertain to the flood plain regulations, staff concludes that the criteria necessary for the
approval of the Conditional Use Permit to Allow the Alternative Method of Elevation are
met; that is, the use of the existing garages to meet the elevation requirement in lieu of
the requirement that compacted fill be placed 18 feet around the perimeter of the
structure to a minimum height of 3 feet above base flood elevation.
If the Board approves the Conditional Use Permit and the accompanying Special Use
Permit, the applicant will complete the necessary plans for a building permit. Staff will
review those plans and building permit application to ensure compliance with all other
aspects of the flood plain regulations prior to issuing a local Flood Plain Development
Permit.
ALTERNATIVES:
1. The Zoning Board of Adjustment can approve the Conditional Use Permit to
Allow the Alternative Method of Elevation for the reconstruction of the multi-family
housing at 301 S. 5th Street as shown on the site plan updated and submitted on
November 8, 2012 by FOX Engineering and the architectural drawing updated
and submitted on November 8, 2012 by Roseland Mackey Harris Architects
based upon the findings and conclusions of staff.
2. The Zoning Board of Adjustment can deny the Conditional Use Permit to Allow
the Alternative Method of Elevation for the reconstruction of the multi-family
housing at 301 S. 5th Street as shown on the site plan updated and submitted on
November 8, 2012 by FOX Engineering and the architectural drawing updated
5
and submitted on November 8, 2012 by Roseland Mackey Harris Architects if the
Board determines that the proposed elevation results in unnecessary risk to
residents or the other factors as noted in Section 9.7 of the flood plain
regulations.
3. Action on this request can be postponed and referred back to City staff and/or
the applicant for additional information.
DEPARTMENT RECOMMENDATION:
Based upon the Findings of Fact and Conclusions above, it is the recommendation of
the Department of Planning and Housing that the Zoning Board of Adjustment approve
the Conditional Use Permit to Allow the Alternative Method of Elevation for the
reconstruction of the multi-family housing at 301 S. 5th Street as shown on the site plan
updated and submitted on November 8, 2012 by FOX Engineering and the architectural
drawing updated and submitted on November 8, 2012 by Roseland Mackey Harris
Architects based upon the findings and conclusions of staff.
SAPLAN_SWCouncil Boards Commissions\ZBA\Conditional Use in Floodway\301_S_5th_Rebuild_CUP_Alt_Elev-11-14-12.docx