HomeMy WebLinkAboutA6 ITEM #: 5
DATE: 08-08-12
CITY OF AMES
DEPARTMENT OF PLANNING AND HOUSING
REPORT TO THE ZONING BOARD OF ADJUSTMENT
DATE PREPARED: August 3, 2012
CASE FILE NO.: ZBA-12-18
REQUEST: To allow excavation in the floodway at 1400 SE 16th Street
PROPERTY OWNER: Pyle Land LLC, Dennis Pyle
CONTACT: Scott Renaud, FOX Engineering
LOCATION: 1400 SE 16th Street
ZONING: A (Agriculture)
ZONING OVERLAY: FW Floodway Overlay District
FEMA F.I.R.M. DESIGNATION: AE-Floodway
BACKGROUND AND PROJECT DESCRIPTION:
The applicant proposes to excavate the east bank of the Skunk River in order to
improve water flow. This request is driven by the desire of the prospective owner (Deery
Brothers) to seek tax abatement for a proposed auto dealership on land adjacent to this
site. The criteria for having the property designated as an urban revitalization area is
that, among other things, the owner must "...perform channel improvements (widening,
straightening, clearing, etc.) and provide certification from an engineer registered in
Iowa that the improvements will mitigate flooding...."
The proposed channel improvements involve relocating the top of the east bank about
115 feet to the east at its greatest extent. The bank will be regraded with a "bench"
about 20 feet wide. The portion of the bank above the bench will be graded to a 4:1
slope. The portion of the bank below the bench will be graded to a 3:1 slope. The
upstream portion of the realigned channel will have riprap installed to reduce erosion.
The remainder will be seeded.
The Board may remember that a Conditional Use Permit in the Floodway was approved
for this site in March, 2012. The permit was to allow the construction of a borrow pit to
extract fill for development on the adjacent property. That permit included a number of
conditions, including 1) obtain a Flood Plain Development Permit prior to excavation
and comply with any conditions imposed therein, 2) obtain a COSESCO permit prior to
1
excavation, and 3) provide a signed easement for recording to establish the proposed
easement prior to excavation. These conditions have not yet been met, nor has
excavation started.
APPLICABLE CODE SUMMARY:
Below are excerpts of Chapter 9, Flood Plain Zoning Regulations, of the Ames
Municipal Code. These excerpts provide the standards on which the project is to be
evaluated (Section 9.4(3) and Section 9.5(2)), and describe the factors on which the
Zoning Board of Adjustment must consider in rendering a decision (Section
9.7(3)(e)(ii)(a)). Following the standards and the factors, staff has provided comments
based upon an analysis of the site, the submitted project details, and consultation with
appropriate City and State officials.
Conditional Uses Allowed
(2) Conditional Uses. The following uses which involve structures (temporary or
permanent), fill, or storage of materials or equipment may be permitted only upon
issuance of a Conditional Use Permit by the Zoning Board of Adjustment as
provided for in Sec. 9.7. Such uses must also meet the applicable provisions of
the Floodway Overlay District Performance Standards.
(a) Uses or structures accessory to open-space uses.
(b) Circuses, carnivals, and similar transient amusement enterprises.
(c) Drive-in theaters, new and used car lots, roadside stands, signs, and
billboards.
(d) Extraction of sand, gravel, and other materials.
(e) Marinas, boat rentals, docks, piers, wharves.
(f) Utility transmission lines, underground pipelines.
(g) Other uses similar in nature to uses described as permitted uses or
listed conditional uses, which are consistent with the performance
standards of Subsection (3) below and the general spirit and purpose of
this ordinance.
Floodway Performance Standards
Section 9.4(3) describes the performance standards for conditional uses that are
allowed by the Board. Following the code excerpts are staff comments. The applicant's
statements addressing these standards are included in his application.
(3) Performance Standards. All Floodway Overlay District uses allowed as a
Permitted or Conditional Use shall meet the following standards:
(a) No use shall be permitted in the Floodway Overlay District that would
result in any increase in the base flood elevation level. Consideration of
the effects of any development on flood levels shall be based upon the
assumption that an equal degree of development would be allowed for
similarly situated lands. Evidence required will be a hydraulic study
performed by a registered professional engineer for the area of drainage
involved.
2
(b) All uses within the Floodway Overlay District shall:
(i) Be consistent with the need to minimize flood damage.
(ii) Use construction methods and practices that will minimize and
resist flood damage.
(iii) Use construction materials and utility equipment that are
resistant to flood damage.
(c) No use shall affect the capacity or conveyance of the channel or
floodway or any tributary to the main stream, drainage ditch, or any other
drainage facility or system.
(d) Structures, buildings and sanitary and utility systems, if permitted, shall
meet the applicable performance standards of the Floodway Fringe
Overlay District and shall be constructed or aligned to present the
minimum possible resistance to flood flows.
(e) Buildings, if permitted, shall have a low flood damage potential and
shall not be for human habitation.
(f) Storage of materials or equipment that are buoyant, flammable,
explosive or injurious to human, animal or plant life is prohibited. Storage
of other material may be allowed if readily removable from the Floodway
Overlay District within the time available after flood warning.
(g) Watercourse alterations or relocations (channel changes and
modifications) must be designed to maintain the flood carrying capacity
within the altered or relocated portion. In addition, such alterations or
relocations must be approved by the Department of Natural Resources.
(h) Any fill allowed in the floodway must be shown to have some public
beneficial purpose and shall be limited to the minimum amount necessary.
(i) Pipeline river or stream crossings shall be buried in the streambed and
banks or otherwise sufficiently protected to prevent rupture due to channel
degradation and meandering or due to the action of flood flows.
(j) It shall be the responsibility of adjacent property owners to maintain the
location and carrying capacity of the floodway adjacent to their property.
(a) The applicant has not yet provided an "Engineering `No-Rise' Certificate".
Once it is submitted, it will be reviewed by City planning and engineering staff. A
report will be submitted at or prior to the Zoning Board of Adjustment meeting.
(b) There is no construction planned. The site will be excavated and seeded. The
purpose of the realignment is to allow the owner to meet the requirements of the City
Council to apply for an urban revitalization area. If the area is so designated, the owner
may apply for tax abatement.
(c) The excavation site is adjacent to the channel of the river. The Iowa Department
of Natural Resources is reviewing the proposal to determine whether an IDNR and
Army Corp of Engineer Joint Permit is needed. One alternative noted below includes a
condition that approval from the IDNR and Army Corp be obtained, if needed.
City staff also provided copies of the application and request to the Iowa Department of
Transportation for their review. Approximately 40 percent of the proposed project lies
3
within the right-of-way of US 30. The IDOT is reviewing the project and, if acceptable to
them, will issue a Permit to Perform Work in the Right-of-Way. One alternative noted
below includes a condition that approval from the IDOT be obtained.
(d) There will be no structures.
(e) There will be no buildings.
(f) There will be no storage within the floodway.
(g) As noted above, the IDNR is evaluating whether the proposed excavation will
require a formal permit from IDNR and the Army Corps of Engineers.
(h) No fill will be introduced on site. All excavated material will be removed from the
Floodway.
(i) The project does not include any stream crossings. However, there is a water line
adjacent to the excavation site that carries the city's raw water from the well fields south
of US 30. This water line is parallel to and on the east bank of the Skunk River. The
water main lies within a 30-foot easement. The top of the proposed excavation is 60 feet
(at its closest) from the edge of the easement. Water and Pollution Control staff has
reviewed the proposed excavation and are satisfied that the water main is sufficiently
protected, although they would like to note that the excavation that was anticipated was
the borrow pit that was approved in March. There was no indication that the river would
be aligned during the design of the raw water main installation.
0) The property owner is the responsible party for maintaining the area within and
around the project site. City staff and the IDNR are awaiting information from the
applicant to verify the claim that the capacity of the channel is increased approximately
25 percent.
Factors Upon Which the Decision Shall be Based
Section 9.7(3)(e)(2)(a) describes the factors that the Board must consider when
approving a Conditional Use Permit.
a. Factors Upon Which the Decision of the Board Shall be Based. In passing
upon requests for Conditional Uses or Variances, the Zoning Board shall
consider all relevant factors specified in other sections of this ordinance and:
1. The danger to life and property due to increased flood heights or
velocities caused by encroachments.
2. The danger that materials may be swept onto other lands or
downstream to the injury of others.
3. The proposed water supply and sanitation systems and the ability of
these systems to prevent disease, contamination and unsanitary
conditions.
4. The susceptibility of the proposed facility and its contents to flood
damage and the effect of such damage on the individual owner.
4
5. The importance of the services provided by the proposed facility to the
community.
6. The requirements of the facility for a flood plain location.
7. The availability of alternative locations not subject to flooding for the
proposed use.
8. The compatibility of the proposed use with existing development and
development anticipated in the foreseeable future.
9. The relationship of the proposed use to the comprehensive plan and
flood plain management program for the area.
10. The safety of access to the property in times of flood for ordinary and
emergency vehicles.
11. The expected heights, velocity, duration, rate of rise and sediment
transport of the flood water expected at the site.
12. Such other factors which are relevant to the purpose of this ordinance.
In considering these factors, staff offers the following comments for the consideration of
the Board.
1. The applicant has not yet provided a Certificate of No-Rise for this request.
It is this certificate which provides the evidence that flood heights will not
increase.
2. There will be no structures or materials stored on-site. There will be nothing that
can be swept downstream in the event of a flood.
3. The site will not have water or sanitary sewer service. City staff has reviewed the
proposal and weighed the impact of the proposed project on the raw water main that
lies nearby. City staff believes the remaining cover, while not the best case, is sufficient
for their needs.
4. It is anticipated that this site will be inundated during a flood event. However, there
would be no structural damage as there are no structures proposed in the floodway.
5. The realignment of the channel is to increase water flows through the channel.
6 & 7. The channel realignment can be done only at this location.
8. Staff can find no evidence that the proposed realigned channel and benched bank
will not have a negative impact on the adjacent development.
9. The Ames Land Use Policy Plan identifies this area as Agriculture and Farmstead
with a Greenways overlay. The proposed excavation is not inconsistent with these
designations. The area between the excavation and the river bank will remain as a
riparian corridor, consistent with the Greenway overlay designation.
10. Access to the US 30 bridge, the SE 16th Street bridge, and the raw water line will
be maintained through two access easements across the site. One was established as
5
part of the water main installation and the other will be established as part of the
previously approved project or through the proposed platting of the Deery site.
11 . A signed Certificate of No-Rise by a registered engineer is necessary in
order to state whether this criteria is satisfied. The permanent seeded areas will
likely reduce sedimentation to a greater extent than the current farming practices do.
CONCLUSION:
Based upon the above analysis of the project which included a reading of the relevant
portions of the Flood Plain Zoning Regulations, consideration of the information
supplied by the applicant, and consultation with relevant City officials, staff concludes
that the proposed development meets all criteria for approving the requested conditional
use permit except as noted, that is, the approval of the Iowa Department of Natural
Resources and Army Corps of Engineers, if needed, and the Iowa Department of
Transportation for that portion of the work that is proposed for the US 30 right-of-way.
The applicant has not yet provided an "Engineering `No-Rise' Certificate". Once it
is submitted, it will be reviewed by City planning and engineering staff. A report
will be submitted at or prior to the Zoning Board of Adjustment meeting. If the
Certificate is not provided in time for review, or is not acceptable, City staff will
ask that the Board table this request to a subsequent meeting.
ALTERNATIVES:
1. If the Certificate of No-Rise is submitted, reviewed, and found acceptable, then
the Zoning Board of Adjustment may approve the Conditional Use Permit based
on the staff's analysis and conclusions. Staff proposes the following conditions to
accompany this alternative:
a) The applicant obtain a Flood Plain Development Permit prior to excavation
and comply with any conditions imposed therein.
b) The applicant obtain a COSECSO permit prior to excavation.
c) The applicant meet any permitting requirements of the Iowa Department of
Natural Resources and the Army Corps of Engineers prior to any work being
done and comply with any conditions imposed therein.
d) The applicant obtain an approved Permit to Perform Work in the Right-of-
Way from the Iowa Department of Transportation prior to any work being done
and comply with any conditions imposed therein.
2. The Zoning Board of Adjustment may deny this request for a Conditional Use
Permit if the board's findings are that the standard(s) have not been met,
detailing the specific shortfalls.
3. The Zoning Board of Adjustment may table this request for a Conditional Use
Permit and request additional information from the developer, City staff, or Iowa
Department of Natural Resources, and subsequently render a decision within a
reasonable time period.
6
STAFF RECOMMENDATION:
The Department of Planning & Housing recommends that the Zoning Board of
Adjustments act in accordance with Alternative #1, which is to approve the Conditional
Use Permit for development in the Flood Way Overlay District based on the staff
findings and with the conditions noted.
SAPLAN_SHR\Council Boards Commissions\ZBA\Conditional Use in Floodway\1400_SE 16th-Excavation in Floodway-08-08-
12.docx —
7
Attachment A: Location Map
Floodwvay
Previously Approved
Borrow site
R1 Site
Floodway Fringe
Proposed
-- Excavation Site '------ .�_� 884
SE 1
MP
88
US Ht+GHVVAY-11� _._..._. 882 882
Floodway Fringe
Floodway Fringe
Floodway «,
r•
N
Feet
G 00 400
8
(2) Establishment of Official Flood Plain Zoning Map. The Story County,Iowa and Incorporated
Areas Flood Insurance Rate Map(FIRM),City of Ames Panels 135, 140, 141, 142, 143, 144, 155, 161, 162, 163, 164,
168, 170, 256, 257, 276, and 277 dated February 20, 2008, prepared as part of the Federal Emergency Management
Agency(FEMA)Flood Insurance Rate Map(FIRM),Flood Insurance Study dated February 20,2008,and Digital FIRM
equivalents are hereby adopted by reference and declared to be the Official Flood Plain Zoning Map.
(3) Rules for Interpretation of District Boundaries.The boundaries of the zoning district shall be
determined by scaling distances on the Official Flood Plain Zoning Map.Where interpretation is needed as to the exact
location of the boundaries of the district as shown on the Official Zoning Map,the Flood Plain Administrator shall make
the necessary interpretation,provided however,that the Flood Plain Administrator may require the owner to provide a
topographic survey of the land to assist in that interpretation.The person contesting the location of the district boundary
shall be given a reasonable opportunity to present his or her case and submit technical evidence.
(4) Compliance.No structure or land shall hereafter be used and no structure shall be located,extended,
converted or structurally altered without full compliance with the terms of this chapter and other applicable regulations
which apply to uses within the jurisdiction of this ordinance.
(5) Abrogation and Greater Restrictions.It is not intended by this ordinance to repeal,abrogate or impair
any existing easements,covenants,or deed restrictions.However,where this ordinance imposes greater restrictions,the
provisions of this ordinance shall prevail.All other ordinances inconsistent with this ordinance are hereby repealed to
the extent of the inconsistency only.
(6) Interpretation.In their interpretation and application,the provisions of this ordinance shall be held to
be minimum requirements and shall be liberally construed in favor of the governing body and shall not be deemed a
limitation or repeal of any other powers granted by State statutes.
(7) Warning and Disclaimer of Liability.The degree of flood protection required by this ordinance is
considered reasonable for regulatory purposes and is based on engineering and scientific methods of study.Larger floods
may occur on rare occasions.Flood heights may be increased by man-made or natural causes,such as ice jams and bridge
openings restricted by debris. This ordinance does not imply that areas outside the flood plain districts or land uses
permitted within such districts will be free from flooding or flood damages.This ordinance shall not create liability on
the part of the City of Ames, Iowa,or any officer or employee thereof for any flood damages that result from reliance
on this ordinance or any administrative decision lawfully made thereunder.
(8) Severability.If any section,clause,provision or portion of this ordinance is adjudged unconstitutional
or invalid by a court of competent jurisdiction, the remainder of this ordinance shall not be affected thereby.
Sec.9.3.ESTABLISHMENT OF ZONING OVERLAY DISTRICTS.
The flood plain areas within the jurisdiction of this ordinance are hereby divided into the following zoning
overlay districts:
(1) Floodway Overlay District-The Floodway Overlay District includes the areas shown as"Floodway
Areas in Zone AE"on the Official Flood Plain Zoning Map
(2) Floodway Fringe Overlay District-The Floodway Fringe Overlay District includes the areas shown
as"Zone AE excluding the Floodway Areas in Zone AE"on the Official Flood Plain Zoning Map.
(3) General Flood Plain Overlay District—The General Flood Plain Overlay District includes the areas
shown as"Zone A"on the Official Flood Plain Zoning Map
Within these districts, all uses not allowed as Permitted Uses or authorized as Conditional Uses are prohibited unless
a use variance to the terms of this ordinance is granted after due consideration by the Zoning Board of Adjustment.
Sec.9.4. FLOODWAY OVERLAY DISTRICT.
(1) Permitted Uses. The following uses shall be permitted within the Floodway Overlay District to the
extent they are not prohibited by any other ordinance or underlying zoning district regulation,and provided they do not
include placement of structures, factory-built homes, fill or other obstruction the storage of materials or equipment,
excavation,or alteration of a watercourse(except as needed for public infrastructure):
(a) Agricultural uses such as general farming,pasture,grazing,outdoor plant nurseries,
horticulture,viticulture, truck farming, forestry,sod farming,and wild crop harvesting.
Sup#201 I-4 9-2
Rev. 10-1-1 1
(b) Industrial-commercial uses such as loading areas,parking areas, airport landing strips.
(c) Private and public recreational uses such as golf courses,tennis courts,driving ranges,
archery ranges,picnic grounds,boat launching ramps,swimming areas,parks,wildlife and nature preserves,game farms,
fish hatcheries,shooting preserves,target ranges,trap and skeet ranges,hunting and fishing areas,hiking and horseback
riding trails.
(d) Residential uses such as lawns,gardens,parking areas and play areas.
(e) Such other open-space uses similar in nature to the above uses.
M Public infrastructure such as bridges; roads; trails; culverts; fill, excavation or grading;
channel changes,relocations or placement of riprap or similar material;provided that any required permits from the Iowa
Department of Natural Resources or Army Corps of Engineers have been approved. Such uses must also meet the
applicable provisions of the Floodway Overlay District Performance Standards.This also includes any activity defined
as maintenance under the nationwide permit issued by the Army Corps of Engineers.
(Ord. No. 4086, 09-27-11)
(2) Conditional Uses.The following uses which involve structures(temporary or permanent), fill,or
storage of materials or equipment may be permitted only upon issuance of a Conditional Use Permit by the Zoning
Board of Adjustment as provided for in Sec.9.7. Such uses must also meet the applicable provisions of the
Floodway Overlay District Performance Standards.
(a) Uses or structures accessory to open-space uses.
(b) Circuses, carnivals, and similar transient amusement enterprises.
(c) Drive-in theaters,new and used car lots,roadside stands, signs,and billboards.
(d) Extraction of sand,gravel,and other materials.
(e) Marinas,boat rentals,docks,piers,wharves.
(f) Utility transmission lines,underground pipelines.
(g) Other uses similar in nature to uses described as permitted uses or listed conditional uses,
which are consistent with the performance standards of Subsection(3)below and the general spirit and purpose of
this ordinance.
(3) Performance Standards.All Floodway Overlay District uses allowed as a Permitted or Conditional Use
shall meet the following standards:
(a) No use shall be permitted in the Floodway Overlay District that would result in any
Increase in the base flood elevation level. Consideration of the effects of any development on flood levels shall be
based upon the assumption that an equal degree of development would be allowed for similarly situated lands.
Evidence required will be a hydraulic study performed by a licensed professional engineer for the area of drainage
involved.
(Ord. No. 4087, 09-27-11)
(b) All uses within the Floodway Overlay District shall:
(i) Be consistent with the need to minimize flood damage.
(ii) Use construction methods and practices that will minimize and resist flood
damage.
(iii) Use construction materials and utility equipment that are resistant to flood
damage.
(c) No use shall affect the capacity or conveyance of the channel or floodway or any tributary
to the main stream,drainage ditch,or any other drainage facility or system.
(d) Structures,buildings and sanitary and utility systems,if permitted, shall meet the
applicable performance standards of the Floodway Fringe Overlay District and shall be constructed or aligned to
present the minimum possible resistance to flood flows.
human habitation.(e) Buildings, if permitted,shall have a low flood damage potential and shall not be for
(f) Storage of materials or equipment that are buoyant,flammable,explosive or injurious to
human,animal or plant life is prohibited. Storage of other material may be allowed if readily removable from the
Floodway Overlay District within the time available after flood warning.
(g) Watercourse alterations or relocations(channel changes and modifications)must be
designed to maintain the flood carrying capacity within the altered or relocated portion. In addition,such alterations
or relocations must be approved by the Department of Natural Resources.
Sup#2011-4 9-3
Rev. 10-1-1 1
DRAWING FILENAME
K:!ro 5000 5174-12a car dealershi Drawin s\Crvil 5174-12A DEERY SITEPLAN.dw
PLOT STYLE TABLE LAVER MNGR NAME LAYOUT NAME
F-Gra 5cale.ctb CU-1
1g0.81
Ea `1
`qo0
tl`O�o0856t 867
I
N � I
o r
m�W
0
� 6L8
i
i f
� I
m w o oar W
2 na0
m
m p
n I I
C u m
N �
Z I
A S3?36 �
S I
m > �-
m { r
v s m
>
M rn m Ns
A p�G�
N W
H
T W 881� nQ
•A
\ .9
ymN
X m
mO
n3 �+ GI z
aZ D py
Z
' Z p Z N H
0 m p g o eej W
� mm e � 888 1 86' aw'
n C m
D L =
a � D40 ,
Z Z00
-
II
00 00 o At
Qom \
oinLrl
rl
w ' \
n + m �i \
F w n W 11 ,, „
Q7 A li. N N W
00
b
n m 5'SIDE S BACK
i
. . .
W -
=A - T'E—. . . . . . . .
9IDE
OJ I{{
Pto
ppp VVVVVV
M a c m W
V
A = � a'
:sS T.'i.Q m''. IIII
sow-esz(ste) :xvd 000a'esz(sls):auovd 6uiiaau 133NV1MSOI'S3WV
Ii19THl OOS
01005 eMOl'SaW1 ilWU3d 3Sn IVNOLLION 00
LOL Vld 3115 S'dOlOWSi310M9 A d;](]
saliossyBu 3X0 (dIVdl'd 2OAR MmiS) NVId!I
NOIS(A3N 31V4 oul voa
� G
z 11
� W W
Z W � m
LLI H G
Ix 0. j
/�\ U uf0Q ¢ p LU
VJF Zou Nut in
Zi
QZ Z O 0Vj y 0 Z
fY QZ 1LL W
\\ W F O W Y �U C
/ Su Z0Z =QZ wLU oo
/ QLL JFm Up. Hit+
/ \� a=o� LU
Z mou o�U
F
zx �UOz zQO z to
x�
/ W W a(Zy~Q QY J W W>
Co p, W J O x Vl Q U Ix
J j mO0C ZmQ (D °1
J z (A
/ Vl IA Q V to W" m C C Z 0,W
/ m z Q LL Z W a J n O z
x W O 3�F OCL th
-
IM
CL
wZJ 44X4 -14Z LU
Ca
W J Z f H 0 Q W W J
Q y U Z JZH
Z�x xZzx z3 LWU m aoa
�+ x a C
OUW a
QW x O J WJA
WWzO 0JS V
iZ LU ZX IL AIJOO
0x JW W0 N COW0QU
eg
D U IL Q 0 D W W a x O x =O W m
UaG z W W= �o-~ixF �0 W J
.�H j. i LL.
OC W OC LU JI-j ZNVx
6 m //� 1 IL Q Q z W O Fd z
Lu<0 Lu
/ th C, Z CoLU 0 (A
a.uj
F 7 I O Wu� fIL4Q NWQW (A O WF
.3 Lu 4
IMw z .-�V10' NQzx MV1UM d'(A In Ix
It
W I zo
a oo =
W
E 1-
W F
W
U.
r X' "�kfr, rjt L J
5
Z LU a
W a O Q
a F Q qTe R F (n O f a ~
W �SeM MqN IM U W
,�� fNT > f W
" -' N V h
W
4 Y` z Q C
as Z a
z
o
w,Dow
z,Z. I I I
namo Ii ra l ^= y
�m
zzpz � � I �ar� w cg U)
N
I
>w am 00+{ I[r III (I i _ x =y J
F U U W
���zp5�a II "�.'r � z z
IM
u IIII i uj
U.
II I Ie om¢ I I ` z N V
M H m. W F
LU
coZ U.z
Wa= I N (n
s �`I�II 11 li In a m I Y
DRAWING FILENAME
K:! ro'5wu\5174-12a car dealershi\Drawin s\Cvll\Skunk River Re air.dw
PLOT STYLE TABLE I LAYER MNGR NAME LAYOUT NAME
FoxGra Scale.aD CU-3
A
cy
m ro m m w ro m
a m a v a m
2
F
W
O
8,0
a
O
H 8J5
N
a;
F
O
O
I A
{
Z o rya D �J
O D
n a,g
L
pM D
o A ✓ `
G
SLS
y\
0
0
10 'A LO_'. O A.