Loading...
HomeMy WebLinkAboutA020 - Council Action Form dated October 10, 2017 ITEM #: 33 DATE: 10-10-17 COUNCIL ACTION FORM REQUEST: MAJOR SITE DEVELOPMENT PLAN FOR 2151 COTTONWOOD ROAD BACKGROUND: Hunziker Development Company, LLC is requesting approval of a Major Site Development Plan for a 12-unit apartment building on the property located at 2151 Cottonwood Road, (Lot 5 of Village Park Subdivision). Lot 5 includes 40,811.28 square feet (0.94 acres), and is zoned as "FS-RM" (Suburban Residential Medium Density), (See Attachment A: Location & Zoning Map & Attachment B: Major Site Development Plan.) The site is located west of University Boulevard, across from the Iowa State University Research Park, and south of Christofferson Park. Land to the west and south of the Village Park Subdivision is outside the Ames corporate limits, in rural Story County. Although the land to the west is outside of the City, it is planned for future annexation and development with single-family homes. A two-story, 12-unit apartment building is proposed for Lot 5 as the final developable lot facing Cottonwood. The proposed building includes four (1-bedroom units), and eight (2-bedroom) units for a total of 20 bedrooms, with an average of 1.67 bedrooms per unit (See Attachment B: Site Plan & E: Floor Plans). The other four lots on the north side of Cottonwood Road were approved for the construction of a 12-unit (3-story) apartment building on each lot along the north side of Cottonwood Road. These four buildings follow a pattern and orientation that features the buildings facing the street, with surface parking along one side of the building, and behind the building in the rear yard, and garages along the north property line of each lot. The proposed development on Lot 5 includes front doors to individual units on the south fagade that are perpendicular to Cottonwood Road, meaning they are not visible directly from the street. The first level units each have a separate entrance at ground level from the exterior of the building. Interior stairs provide access to the second level units, with exterior doors on the east and west sides of the building. The proposed building design is a 2-story building with a flat roof (See Attachment C: Building Elevations and Rendering). Exterior building materials include a combination of vertical flush seam metal panels, and galvalume finish corrugated metal siding with a vertical or a horizontal orientation on various sections of each wall. The metal panels, and galvalume finish corrugated metal siding extend above the roof line at various heights to form a parapet along the south building elevation. The north and south building elevations include four small sections of reddish brown face brick as accents, while the east and west elevations each have one small section of face brick on each wall. The design has a very modern style architectural appearance with the flat roof and parapets that are similar to some commercial building features. The parapets are intended to address architectural interest for the building. Staff believes the design creates some desirable architectural interest but the extended parapet heights also 1 create some disproportionately tall fagade elements compared to the main area of the building. The proposed building design is a departure from the architectural design of the other 12-unit apartment buildings approved along the north side of Cottonwood Road, which are 3-story buildings with gabled roofs. Exterior building materials for the other buildings include vinyl lap siding with cultured stone veneers, and cultured stone pillars that support decks and roofs above the decks, as well as above the primary entry to each building. The developer also intends to propose two-story flat roof buildings of the same type as this application for remaining undeveloped lots located on Aurora. Two garage buildings are planned along the north property line, with six parking stalls in each garage building. Surface parking spaces are located along the east property line, and behind the apartment building. The parking spaces behind the building share an access aisle with the garage parking stalls. Access to the site for parking is a shared access easement centered on the property line between Lot 4 (2135 Cottonwood Road), and Lot 5 (2151 Cottonwood Road). . The FS-RM zone includes requirements for common open space equaling 10% of the overall FS-RM area in a development. The common open space that serves the tenants of the proposed apartment building, and all lots in the FS-RM portion of Village Park Subdivision, is located within outlots (See Attachment F: Open Space Landscape Plan). Notably, Outlot B abuts this site and provides a walkway connection from Cottonwood to the Christofferson Park boundary to the north. The other outlots in the subdivision are principally designed for stormwater treatment facilities. Landscaping on Lot 5 is provided to meet the new residential landscaping standards for residential development. This includes new front yard landscaping requirements and for the parking lot. The site also triggers FS development standards for side and rear yard landscaping, notably for the west property line that will be a future interface with single family development. A high screen is required along the west property line to meet landscape buffer requirement in the FS-RM zone where the lot is adjacent to any lot zoned as FS-RL or RL. Staff has recommended that the developer propose an alternative landscape approach for the high screen and outlot along the west property line. The developer proposes provide the landscape buffer along the west 10 feet of Outlot B, abutting the west property line of this site and to construct the required walk along the east side of the outlot. City staff is supportive of locating the buffer in the Outlot to ensure the walkway is visible and not cutoff by landscaping. The property owner of Lot 5 would be responsible for the long term maintenance of the landscaping if it is not cared for as part of the common area as it is a substitution for onsite landscaping. Off-street parking exceeds minimum parking requirements for apartment dwellings in the FS-RM zone. Access is shared with the adjoining property as required within the subdivision plat. No lighting has been proposed with the site development plan. Further details on the overall plans are found in the Addendum of this report. On September 20, 2017, the Planning and Zoning Commission reviewed the proposed Major Site Development Plan. The Commission discussed the site layout, open space, access, landscaping, and design of the project. The Commission reviewed the architectural plans and details and considered how the style of the buildings would be 2 compatible in appearance with future single-family neighbors to the west, especially for future sites along Aurora. The Commission also discussed the view of the site from Christofferson Park. By a vote of 6-0, the Commission recommended approval of the Major Site Development Plan and added a condition of approval for buffer landscaping along the Park boundary. The Commission believes a landscape buffer is needed to break up the expanse of blank walls on the north side of the two six-stall garage structures. The developer has satisfied the recommended condition from the Commission by adding landscaping to the plans included for the City Council's approval. ALTERNATIVES: 1. The City Council can approve the Major Site Development Plan for the proposed 12- unit apartment building, located at 2151 Cottonwood Road, as proposed, with the following conditions: A. Review of an outdoor lighting plan is deferred for staff review and compliance with the Outdoor Lighting Code, Section 29.411 of the Municipal Code. B. Prior to occupancy, complete the High Screen plantings within Outlot B as a substitute for onsite plantings. 2. The City Council can approve the Major Site Development Plan for the proposed 12- unit apartment building, located at 2151 Cottonwood Road, with modifications. 3. The City Council can deny the Major Site Development Plan for the proposed 12-unit apartment building, if it finds the project does not meet the Major site Development Plan criteria. 4. Action on this request can be postponed and referred back to City staff and/or the applicant for additional information. CITY MANAGER'S RECOMMENDED ACTION: The Major Site Development Plan review is to determine conformance with development standards, and appropriate arrangement and design of the use of the site. FS-RM zoning is intended to implement the LUPP vision of landscaped suburban style development that provides for desirable apartment housing choices. The proposed development project is consistent with the Master Plan for use limitations and meets a community interest of providing for apartment types of various floor plans from one to two bedrooms that will have wide appeal. The specific criteria for the site development plan approval are discussed in greater detail in the addendum. The proposed building design is consistent with the common expectations of apartment homes marketed above an entry level product in that it includes some covered parking and private spaces for individuals and the units are sized for smaller living situations. As a small site there are no unique amenities or characteristics to the project as have been included with the recent Mortenson Heights projects along Mortenson Road. 3 The building design has a modern design style in terms of its massing and use of exterior materials and architectural features. The proposed materials are very contemporary with the metal siding, parapet on the south building elevation, and the flat roof. There are very few examples of this design approach in Ames outside of commercial areas, which makes it hard to visualize how successful the design will be compared to the other buildings in Village Park. Although staff has some concerns on individual features of the design, the modern style in this area of Village Park can be found compatible with the surroundings. Staff has worked with the applicant to provide landscaping on-site to meet front yard, and perimeter parking lot landscaping requirements. The arrangement of the site has a residential appearance for landscaping. With the required street trees and front yard plantings, the development of all the sites along Cottonwood will create a substantial landscaped corridor. Staff supports the use of Outlot B to meet the high screen requirements while accommodating the walkway connection to the park boundary. The developer has added additional landscaping along the park boundary to soften the appearance of the site from the public park. Therefore, it is the City Manager's recommendation that the City Council act in accordance with Alternative #1, approving the Major Site Development Plan with the conditions stated above. 4 ADDENDUM Project Description. Hunziker Development Company, LLC is requesting approval of a Major Site Development Plan for a 12-unit apartment building on the property located at 2151 Cottonwood Road, (Lot 5 of Village Park Subdivision). Lot 5 includes 40,811.28 square feet (0.94 acres), is zoned as "FS-RM" (Suburban Residential Medium Density). (Attachment F: Village Park Subdivision). Development of the property is required to be consistent with the rezoning Master Plan agreement for the property. The Master Plan for this property, originally identified as 3535 S. 530th Avenue (Village Park Subdivision), includes FS-RM and RH (Residential High Density. The Final Plat for Village Park Subdivision includes eleven lots for development in the FS-RM zone, and one lot for development in the "RH" (Residential High Density) zone. Approximately 100 to 120 units, and an approximate density of thirteen to seventeen units per acre is shown on the approved Master Plan for the FS- RM areas. This is the final lot for development along Cottonwood. Attachment F shows the overall layout of the Village Park Subdivision with the open space landscaping. Density limitations in the FS-RM zone requires 7,000 square feet for the first two units, and 1,800 square feet for each additional unit. The subject site could accommodate 20 dwelling units, provided all other site plan requirements are met. The FS-RM zone allows a maximum of 12 units in each building, which is what is proposed for the entire lot. The proposed density of 12 units on 0.94 acres is the equivalent of 12.80 dwelling units per acre, which is within the density range on the approved Master Plan for Village Park Subdivision. The proposed 12-unit building consists of four (1-bedroom units), and eight (2-bedroom units), for a total of twenty bedrooms in the entire building. Parking. The Zoning regulations require a minimum of one parking space per bedroom for units of two bedrooms, or more, and one and one half parking spaces for one-bedroom units. The minimum number of parking spaces required for this site is 22 spaces. The developer is proposing a total of 38 parking spaces, including handicap-accessible spaces and garage stalls. Off-street parking on the site is configured as 19 standard (9'x19') surface parking spaces in the rear yard, north of the building, and 5 standard surface parking spaces, plus 2 van-accessible handicap spaces, as required, in the side yard east of the building. Across the drive aisle from the surface parking spaces in the rear yard, are two (6-stall) garages approximately 12.31 feet from the north property line, and running parallel to the north perimeter of the site. The parking spaces, and garage stalls, are served by a single access from Cottonwood Road, centered on the property line that separates Lots 4 and 5 in a 25-foot wide shared access easement (See Attachment B: Master Plan, Parking Layout). The shared access between Lots 2 and 3, serves as a temporary emergency vehicle access that extends through the Wessex Apartment development adjacent to the north, and out to Oakwood Road, until such time that Cottonwood Road is extended to the west to connect with the existing Cottonwood Road in the Suncrest Subdivision Layout. The proposed building would be constructed on Lot 5, which includes 40,811.28 square feet. The building footprint of the apartment building occupies 6,290 square feet of the 5 site. Garages footprints cover 3,168 square feet, and the parking spaces, driveways, drive aisles, and sidewalks cover an additional 8,945 square feet for a total of 20,013 square feet of the site covered by impervious surfaces, which is 59% of the total site area . The remainder of the lot is landscaped area, which amounts to 41% of the total site. In addition, the minimum requirement of 10% of the gross area of the subdivision to be devoted to common open space, for development in the FS-RL, or FS-RM zones, is accounted for in Outlots A and D, of Village Park Subdivision. Landscaping. Landscaping requirements are derived from parking lot layout, front yard plantings, and transitional buffers. (See Page 20 of the report for the landscape plan). The proposed project's landscaping is predominately required for conformance to the front yard plantings, which are required by the recently adopted residential landscaping standards. The developer has chosen to propose front yard landscaping concentrated along the building fagade rather than distributed throughout the site. Most of the parking areas are screened, with the developer relying upon distance from the street and intervening trees to act as the buffer to parking on the west side of the site. Unlike the properties located east of this site, and north of Cottonwood Road, the rear lot line does not abut the Wessex apartment development. The rear lot line for the property at 2151 Cottonwood abuts Christofferson Park. Screening was not required behind the garages for properties that abut the Wessex apartment development; however, the Planning and Zoning Commission and staff believe it is necessary that large shrubs be included as a buffer between the two 6-stall garage buildings and Christofferson Park to soften the appearance from the open space. The developer has added large shrubs on the back side of the two garage structures, as shown on the revised Landscaping Plan received following the Commission meeting on September 20. A formal high screen planting was not required along the north property line. The west boundary of the site will interface with single-family homes in the future. The FS development standards require a high screen along such an interface. Staff has worked with the developer to place the high screen landscaping within the outlot and move the required walkway connection towards the apartment building. This provide greater visibility and safety along the walkway and meets the intent of a buffer of the use to future single family homes. Front yard plantings requirements include a combination of shrubs, ornamental grasses, as well as understory and overstory trees. The developer has included additional cluster landscaping along the sides of building to meet the minimum screening requirements for the ground-mounted mechanical units. Perimeter parking lot landscaping that includes overstory trees is required along the portions of the driveways, parking spaces, and drive aisles to meet perimeter parking lot landscaping (See Attachment 8: Major Site Development Plan, Landscaping- pg 20). Staff believes the project meets the intended parking lot dispersal requirements as proposed. The trash receptacles are screened with V by 6" vertical cedar wood alternating slats to a height of six feet. The site plan does not include gates for the enclosure due to their orientation. Gates are not necessary to meet screening requirements in Section 6 29.408(3) of the Municipal Code, since the garbage collection enclosure screens the garbage dumpster from all public rights-of-way and from adjacent properties. Circulation. Site access is from one driveway off Cottonwood Road. Cottonwood Road is planned to be extended west to connect to the existing segment of Cottonwood Road, in the Suncrest Subdivision, once the land between Village Park Subdivision and Suncrest Subdivision is annexed into the City and developed as residential. Public sidewalks (5- feet wide) in the right-of-way for Cottonwood Road provide a connection to the shared use path (10-feet wide) that will cross through the site between University Boulevard and the southern boundary of Village Park Subdivision. The shared use path will connect to the Ames community bike trail/shared use path system, and is planned in the future to connect to the regional multi-county bike trail system south of Ames (See Attachment F: Landscape Plan for Outlots A & D, Village Park Subdivision). In addition a 5-foot wide sidewalk in Outlot B, adjacent to the west boundary of Lot 5, will provide access to the Christofferson Park north of Village Park Subdivision. The shared access between Lots 2 and 3, also serves as a temporary emergency vehicle access that extends through the Wessex Apartment development adjacent to the north, and out to Oakwood Road, until such time that Cottonwood Road is extended to the west to connect with the existing Cottonwood Road in the Suncrest Subdivision. Building Design. The overall footprint of the proposed apartment building is approximately 105 feet by 64 feet. Minimum building front, side and rear yard setbacks are all met by the proposed placement of the apartment building on the lot. The site plan shows the garage structures 12.31 feet from the north property line (See Attachment B: Major Site Development Plan). The 12-unit building is consistent with the maximum building size allowed in the FS-RM zoning district. The building is two stories in height. Four stories, or 50 feet, whichever is lower, is the maximum building height permitted for multiple-family dwellings in the FS-RM zone. The apartment building design incorporates a flat roof design with a parapet on the south building elevation. As discussed in the background, the proposed contemporary look is a departure from other designs approaches seen in this area and throughout the community. Staff supports diversity in architectural design overall, but does want to consider the general compatibility and features of a project. Staff believes that use of parapets on one side (front facade) of the building and the elongated height of the parapets does create some disproportionate elements on the front facade. Some modifications to these features could benefit the overall design by extending sidewals back from the parapet into the roof to create the appearance of more mass tied into the overall building rather than a standalone parapet. A different option would be to add shed roof elements with an eave in place of the vertical parapets to enhance interest for the overall massing and create roofline variation. Three primary exterior materials are proposed for the building. The majority of the first and second levels are to be surfaced with a vertical flush seam metal panel and galvalume finished corrugated siding in both a vertical and horizontal orientation. The metal panels and the galvalume corrugated siding will extend above the roof line to form 7 the parapet on the south building elevation. Each unit on the ground level will have an exterior door on the south, or north sides. The doors on the front (south) side of the building will not be visible from the street since they are at a 90 degree angle to the street. Apartment units on the second level will be accessed through an exterior door on the east and west sides of the building leading to stairs to reach the second level. The two (6-stall) garage structures will have similar materials and design features to the apartment building. Galvalume Finish Corrugated Metal Siding, with a horizontal orientation will cover the four walls of each garage. The garages will have a roof that slopes toward the back, but will be concealed by a parapet. Metal trim will be used along the edges of the garage walls, and around each garage door (See Attachment C: Building Elevations &Attachment D: Garage Elevations). Major Site Development Plan Criteria. Additional criteria and standards for review of all Major Site Development Plans are found in Ames Municipal Code Section 29.1502(4)(d) and include the following requirements. When acting upon an application for a Major Site Development Plan approval, the Planning and Zoning Commission and the City Council shall rely upon generally accepted site planning criteria and design standards. These criteria and standards are necessary to fulfill the intent of the Zoning Ordinance, the Land Use Policy Plan, and are the minimum necessary to safeguard the public health, safety, aesthetics, and general welfare. 1. The design of the proposed development shall make adequate provisions for surface and subsurface drainage to limit the rate of increased runoff of surface water to adjacent and downstream property. The Public Works Department has reviewed the storm water management plan and finds that the proposed development has met the required storm water quantity and quality measures by use of the proposed regional detention facilities on the southeast and northeast areas of the site. 2. The design of the proposed development shall make adequate provision for connection to water, sanitary sewer, electrical, and other utility lines within the capacity limits of those utility lines. The existing utilities were reviewed and found adequate to support the anticipated load of 12 dwelling units on this lot, comprising 20 bedrooms, consistent with prior determination at the time of rezoning and subdivision approval. 3. The design of the proposed development shall make adequate provision for fire protection through building placement, acceptable location of flammable materials, and other measures to ensure fire safety. The fire inspector has reviewed access and fire truck circulation, sprinkler, and hydrant requirements and found that the requirements of the Fire Department are met. 4. The design of the proposed development shall not increase the danger of 8 erosion, flooding, landslide, or other endangerment to adjoining and surrounding property. It is not anticipated that this proposed development will be a danger due to its site location and proximity to other uses. 5. Natural topographic and landscape features of the site shall be incorporated into the development design. The site is currently devoid of any significant vegetation. Minimal grading will occur for the construction of the buildings. The site is relatively flat and grading will occur mostly to direct storm water where required. 6. The design of the interior vehicle and pedestrian circulation shall provide for convenient flow of vehicles and movement of pedestrians and shall prevent hazards to adjacent streets or property. Access to this site from Cottonwood Road is through one access point at the southeast corner of the property. Vehicular and pedestrian access is accommodated between the subject property, and other properties (buildings) within the Village Park subdivision. The on-site sidewalks, sidewalks in the public street right-of-ways, and shared use paths provide pathways throughout the site, and to external connections to allow for circulation throughout the community, and eventually within the Central Iowa region. 7. The design of outdoor parking areas, storage yards, trash and dumpster areas, and other exterior features shall be adequately landscaped or screened to minimize potential nuisance and impairment to the use of adjoining property. The general development standards of the zoning ordinance have been met for the screening of parking areas. Gates are not needed on the trash enclosure to comply with the zoning ordinance standards for screening garbage collection areas. In this plan the design has a large opening for rollout of the dumpster with no gate to obscure or secure the dumpster. The apartment building provides a high degree of separation and screening of the parking and garages in the rear yard from adjoining views, and as viewed from Cottonwood Road. 8. The proposed development shall limit entrances and exits upon adjacent streets in order to prevent congestion on adjacent and surrounding streets and in order to provide for safe and orderly vehicle movement. A shared access is planned for the subject property (Lot 5), and the adjacent property to the easement (Lot 4), to minimize the number of curb cuts onto Cottonwood Road. 9. Exterior lighting shall relate to the scale and location of the development in order to maintain adequate security, while preventing a nuisance or hardship to adjacent property or streets. Additional information is needed on the proposed exterior lighting, to determine 9 compliance, prior to the occupancy of the apartment building. The proposed lighting must meet the lighting standards, found in Sec 29.411 of the Municipal Code. 10. The proposed development shall ensure that dust and other forms of air pollution, noise disturbances, odor, glare, and other nuisances will be limited to acceptable levels as prescribed in other applicable State and City regulations. The proposed residential uses are not expected to exceed the level of nuisances, typical of this type of development, beyond acceptable levels, as prescribed in other applicable State and City regulations. 11. Site coverage, building scale, setbacks, and open spaces shall be in proportion with the development property and with existing and planned development and structures, in adjacent and surrounding property. The scale of the proposed apartment building, in relation to the lot size, is appropriate, given minimum building setback requirements, landscaping requirements, and areas of the site planned for parking. The architectural design incorporates various planes to the building and use of exterior materials to create visual interest and address the scale and aesthetics of the building. The developer has proposed the maximum number of units (12) in a multiple family structure within the FS-RM zoning district. The density of development is well within the approximate densities found on the approved Master Plan for this subdivision. Open areas and landscaped areas meet the quantitative standards of the zoning ordinance and allow for informal activities by the future residents of this subdivision. The Development Review Committee has reviewed the Major Site Development Plan and found that it complies with all other requirements of the Ames Municipal Code. 10 Attachment A: Location & Zoning Map UAK!S(> D""D �__ D R Ok' QpD RD— KW.4OD RD" . ptiR M v c y• � �Sl1NCRB38UR _ ' SUNDOWN;DR ' �r' 2151-Cottonwood Rd. � `� TTU;MUYUOD=RD aDTfONNOBD RD•' 9r�t u y ResidentialLowDensdyZbne'RL'[sec29.761); Residential High Qensity-Zone."RH'(sec29.704) �A Highway-Oriented Commercial Zone'HOC'(sec29.804) . ` ',� " Plan ned Industrial Zan a-PI'(see 29.962) �- Research Park Innovation District'RI'(sac29.903):1 4 Government/Airp art District'S-GA'(see 29002) mr. 4�- Suburban Residential Zone Residential LowDensity'FS=RL'(see29.1202(4)-1) 4 . Suburban Residential Zone Residential IAedium Densfty'FS-RIV (see29.1202(4)-2) - " Planned Residence bistrict"F-PRD' (sec29.1263) Location & Zooning Map N 21.51 cottonwood Rd. ° 0. 150300 600 -900 - Feet -. 11 HUNZIKER DEVELOPMENT CO. RECEIVED CONSTRUCTION PLANS FOR OCT 04 2017 '' 2151 COTTON WOOD ROAD, OEPLOFPLRNNNGBH USING ^ GOVERNING SPECIFICATIONS W THEI0I7 UVIMN OFWE'IM—ATEWIDE URBIW SPE-KAROM FOR PUBLIC LIMPOLP�END'AND'IHEUnOFAM[SSUPPIFMEN[ALSPEDFI-1-SHML SHEET INDEX N G LOT 5-VILLAGE PARK SUBDIVISION RIWADEPAMBRI FTRANSPOpiAIION'STANDARDSPKIHGTONSFOR 1 TITLE SHEET HIGHWAYANDBRIWEco 0NSAROM UttAL2wBANMONAL REM0MNEMI /[� SUPPIFMEMALSPFGRGDOMAND MATERWLSINSTRUCTIONAI MEMORANDUM MAJOR SITE DEVELOPMENT PLANS 2 GENERAL NOTES W SHALIGWERNAf RDFAFNCfA JULY2017 3 QUANTITIES AND DETAILS ALLavvlrcaelF FEDERAL,nATE,aNOLOw uwspxooxaxwcfswntBf 4 GRADING AND STORM SEWER coMVlrtOwlmwTxEmxsTRurnoxmTx¢vpoiEn. f MUffD2M9 ADO DBYIOWAO[PMMEMOFTRANSPOR[ATON. S GRADING AND STORM SEWER 6 PARKING LAYOUT 7 PARKING LAYOUT $ a 8 UTILITIES EL o �..=ll a9 UTILITIES i ° R 8 10 LANDSCAPING s S 11 LANDSCAPE DETAILS E , ] OWNER: SIR REST RO 205SITH STREOPMENT COMPANY,LIC 3D6 S 36TH STIIEET CL "- - AMES,IA 5=0 11,° PROJECT LOCATION mmmftz a SUNDOWN - APPLICANT: HUNZIKERDEVELOPMENT COMPANY,IIL _____________ ° _ ____ 1O5S1,50DIOEET O -_....... AMFS,W 50010 N no oHw RD PLAN PREPARED BY: T-1 Q .. ............. BOLTON&MENK,INC. vo.Box 668 2nDFORDSTREET I AMES,IA50010 �/r ...,.. LEGAL DESCRIPnON: T 5 OFL7-5 VILLAGE PARK SUBDIVMON,3ST ADDITION TO THE CITY OF AMES,STORY COUNTY,IOWA L �€ .ZONING DESIGNATION: ' ° ®CIE CALL SUBURBAN RESIDENTVLL MEDIUM DENSTEY FS-RM .� PROPOSED LAND USE: APARTMENT BUILDINGS WWMIDwvononDil.cem MINIMUM BUILDINGSETBAa(5: 4 CITY_OF AMES FRONT LOT UNE:25 FT M NOTE:EInSTING UOUFY IxiopAUDON SNOWN ONTNK yceyxU,y SIDE LOT UNE:10 FT(3 STORY) , ••• I--RE.D(oY.MINTNEUDN[YOWNE0.THE REAR LOT LINE:2S FT cOMMC[ORSHALL FIELD YERI%EfUCT LOCATION PNOR �F TOCOMMENGW CONSfRUrnON AS REQURIFO BY STATE ^� GW,NO[I%IOWAONf GLL]-BOO]B1B989 ^W y THESURSURfAtE UTODYwFORMATN1QU-1EVEL TxeuwimmesinT[m RAVA O,Cav L DMIRMIVAL11Y1F RILING H[ EGUI EUAIIIYLEVFLWAS DEIEPRNNEOAO:ORO—DYNE Gm ES.R 0FcUA5fE o iWESSIU[ COME FN[IRFD STANDARDOUIDELwESFORTNE ® P ROF OW�yyy COLLERIONAND DEPIrnON Oi F%DYING SUBtURfAQ ( UEIUD DATA' GREURY0. e 3l BROUSSPAD �= C , 31�1 Q PLAN REVISIONS 0 yA V nwxom xe u B n]Lmv DATE SHEETNUMBER APPROVED BY MODIFICATIONS SS®CIARPAiS � �E� REALTORS' OWNER ®BOLTON �PD O° HUNZIKER DEVELOPMENT CO. m i HUNZIKER DEVELOPMENT CO. 21S1 COTTONWOOD ROAD 1 Rlsla sFw IDS S.36TH STREET & MENK A.m® AMES,IA50010 TITLE SHEET i i I i ,cxs[iwApArmsxNLcovrt,wrtxAu 4 �� MIxBwRx/m,MANWLB[NUBYeDAw NNCDATMttx,aNlaRf[lud2pumMUlCwnxACTBx sosB,lDe'RufmNo! ���8[ mwni nflTMmmaclroxsuoioA�wnWrtmnn[NnbasartowmsDmxaMmYNaiMrmiEn ' /N wA(rouxfw[wr[nmwau W,NfuU dwflenvoxmolaU,xxaAwlw vnnomLuxnai ruAvxn,wM cBWdAD[swmrvwDtsns[nswu[Dva �{/ AmY[rmn,end[vaumamD[srundamoaouuvmmf[rnwfnytusvn um w.¢nAus'ol Msru�Bummmu,q,n M.UDx.Bwm[nfx[nvrc� � �� Ilpsr,[�[mxlMno119Uuuxn,M[xcBmB/DWnI.m RDWlniuulwfrtnlaV wA(meMlMWmrs[nbN la54 LUTnu __ _ Z _ wmuLmunxrAnor(mmLn[m4LDi'vrwnsAxow[w[s'wrauAxwoss[mxA,4vR u,fx.R nDo[wf(rur�oB�ulMlwRwWn(uAc�twxwxl rtnexraBruMlu(«otYawcxxmx[slmuw[Wwma,dwf[>.nuwGw4v[enGt G I wAUMDAPrtovuwalvx[wv[swn®Im[R6 Ww[uamH iOm,wl frrPdL;WuzGW sassw[vcxs,umrAYw[MMM[MdlvwtB[OPtvf¢BUA¢(rtw1[wMPMUWw[Mwra MUW[unIUfMWms[INvfAssmulDx n¢wrvlq(m'qnn[csvnwrwl[Pmwlx[sLxn®srtorlu,mxyM(ainvPnWLWLmn�wnwnrwxUDrl.wmu,[rmnawxw NL ralnBLl[m�rtinn[BwxAxMlm[oeWOUIDMTufn[mr,rmoLYvsi992•m(alomlrtra WMnoxorrarMcaroux;mrfA0u wv4sal5nWndu,nw.[x[ruenox LwtN,UeU[.wMl°�anrtlm',DIIWfmnup�Wnruna0..Duux,AORl1,.MawlMnmvULL vm[nM61Jmo,rxa vwiyN(utanl�Ts1R[[ vD[osMaMUR1DG1x1 Ww,rawnm, rUa'Smm.WlaOSnuRAY9GxsYUMGIxe w[uw[wxnunAurAwe.rtr[Dw[.Lw(wmer.ouasxed,�nwncewnnucmnfom(rou�sLaDnirnrw,fzsranw® L' ww„xxR.mwMaa[wnunaexwaumixux[�orAxu.Alouww.0 A[m.wxnwmrommr in'M m— � x�M[.w.w[;LTwM`w'"oa"v[o"o"��o.:[°e A:umf',r"ixiuoruG�nlo'r"x[nm„,L.na.Nowdfn[""�oGGo;mf`x`°wL°°:w[""rr ��dw,�w..rswx� I rnoxiura(.ssYwm[woum,vAxwMaumwrrrvMUAxoums.[mrnma o,owmxnrwruxcBPv.AuwfmmoxlMuuumausx.uulw,lwAo[nmwm.na.iww.nw[D[. x¢wa4owx[ewaurawuPraowsssu¢ouu MrwAL[xwum[mdrunoxor Mvmaawmexra,w[sRnnann I �� Wwwv[arv�u(enBu�Browne.w+r�Br uuxmxwiuemoamT.�i¢w�o+s,ra@su(a�iwv[o'ro nrmwiLnm.YmuufRmxo�,xemw�u�nixAo�eDAxa oxm,w xmms[nmv iwaimwdw.mw(ss.[cofoumewMUAxxumss[vxmo. AnDyoxanw[saneuW,eoxwnrexTn[rAYGnmdafxwuuuom � wuzfLufma.11romi+i.d®romGnt:wwnw®to„oommw,nfuuAu..»oDu.aoero[u:n,wn ,(u„swwuu.enamn,x.an�ussoxf�u.AidsxuL�o�.md�nGL I aB[=�,.[ww„GYx[exs�MdroWmwMro,[x,WLmrw�MmxrtA(ro.�a�w[nM >Lmwa�mn(xRLwxx.>EmWA�xnm.�mMnRx,rG(DG.� c 4xAmn„azR�DY[fnD..M ;m� �a, `m����o."�:o�n�R"" PW,nxxw<wm..R,[Dw,�wBxn,�w,wdaB.,Pw.wMfrtm�xf � °,p�mxf.NmxxwRRDDMBD�,d..[m�[(,onwdf.wD,GnRD�DnM.wn.fDx[...[A�nWw�n(�,wnfAddR,�.Aa Q. AAw`mwaox � �: xw mxm m.w wG wRmw. x,w.[R D.m (�om,ro.Wxx�dMwG�dL cf[.��,.P,.w.,14.nD�IfxARro.�A[RDwArux�G�.x[Da,Mm.Dr,� �.,�ra�°�.,,naxwLm�xMm.AYx[w.r[DnaDw,fa,[,wnmM[um�m bx[�mwr,[nlD»LwW>ww.rt.xD.wx�(m.B�,.,�x,arom.�m��w,l[Dmm[m. PB,�wA�[�[nD(Mww.,R[xxLDM(df�n. wmmxmaRn,n.�w„wraro[BwIAW»„N�.wmDM.G�r.�, �, .PM,�nAwGDrtxxGlllwrt.d�BwRYwA...mNwMGx�.[,�,YrwL own: xAr,ww�„.®wdnm,x[.M�[wtxRwM�,.DwBmnn[MeNR.w, Yx,DxwxMB.fw,[� ..�xwRmwL,�w�.(rvfmm�LR�G�x,mWM�WfwxW ,_ __ �,�:[�� ��m�;�fx�; ���_ _�[ffxPnw,.m�R;,°�,� B(wnNDD�RDGPNIG.[n(�dLndfd.�.wn�mwNLnDn�ewMswm,G,�f..Dwwwmw�,.mx.�,wNmrwnDwD VI m[DTs000[oaesammwrtam mx,wc,ousBvwiaeamrouuwe�NLxwwiwAxunv�an ninrartvMmmvAcronrwm��wnn([[Lumuwtawmmunm[e xx[uosshD,ai.uuo..ow.owarr-(.� L uun.(�un�n.YM[xevu[n,rawDwWTB(Dora.MrvxemnroxA[mramu,M[aD[o�A.wn*oMmx,wR,onAnnomDmonwLmlwN ooxAuu.uDimunvtis 0 uwmwmc rmrznfirtrwrx.Bn mRomuxxmuroxd[um,mwexN,nmwuxmomnro.i.wrsw..Duxx,uxe[(uuwu�w�nmuunBdwRo lx[xmuod.uw[xs,suw rxmnuedmux„uoGw.omnsfw[Lxwa,fanw[vwMwuvoxxoxrarunoxxonnvuawnm'wrrnnram[ro � drwW,oxrora[fzweuroenmwNw.®xouavmxuo�mnimaim.lmmfaimorMuu[wwv[oxPrua [nemxf,o.vr.,xamu,oru,wGuiwxrorunwAn[mxmxwu,sw(u � I W m�rcNdruss T �w��L DwmiawllG,(sxn[e45x[Flmcaros[[WDww,uL I }I rAnx[wwA®eDAxnxmxsse,lou)vp,imorranaWosr[osGlm[6YfDr9W[ra,rus[ptwl,mrrsrecrlorAverrtMnsu BaG AT,An®mALLWP1RMu6M1Ml(I[MB[SNALLBFBBOWX(mAlxAR0.WUFisMnWAiNIiWENmGNIiIMmlWwem B[ nrtwA4[sa[aUafMxR �vsBUu[adv nawnWwrmulPws,owesswrn mPaslvwLe(snmMwamuvaxowcrnv[ef[srt[[tvPmi¢ is wnw®sfsrsvuumwaauroanGuf[sasR[uunALv[vfumfu �wUx[uyDxmG roe uxuY.xD mwusoxn v uu L[Auuw[aATA Lr(aUDN Gmr row aw(u txDTmmi(xuvw twxwrd Aoaa[naxtwnvmnmso.nDwsurv- w,ouMxAmum4�MM�+M„�ots�em�raro w�noca m ruMiwvu�Amrsfu,mxmuwumtwsc 1 Qmx,wLo[vxxsAwvBMmatAmsru(w,xt rdv[n. mrw AnmruxcwammomwN[xMUnw Wtsweucxvewnmronrm�cwwrwrrc MEW I�m HUNKER CO.BOLTOd Zul[OUONWOD ROAD ®&MENK D"n � 2 GENERALNOTES i 1 V I �. \\ I • 9Ti 9T5 _ 970 1• _ ^ ''•\ 976 9)6 I6 GARAGESNALLNAWV9EMWALLIFNEEDED �\\ GAMGESNgIL HAVEI ISIEM WAILIi iEEDFD \\\ m 6 STALL GARAGE \ 6 STALL GARAGE FF:974.80 FF-974.10 \• G --- ----- —� -- --- ---% w 4 g75 s— --- --- --- --- --- ---\—^ i V m ^ ^ ^ e� R I I ~ cc lto L '\ I I ^p� ^w•P l i I ❑ ❑ IEGEND SOT fENDE ^,,p ^b^ PROPOSED BUILDING ^w^° ^e✓' I I b q p R:97470 p p I M INIFTPROTECIION Y/ --��_-IXISTING[ONFOURS ' I TIAD„ I \�PRDPOSFDfAN1DUR5 I ��: ElEl❑ ❑ II1J�cc E A=O FORM GRADEUNLESSO7NERWNE NOTFD I ❑ s I'• 69':' I I i Q R FR m IS BOLTON maraxon•Pa m.seR o r� m' awwM HUNZIKER DEVELOPMENT CO. �"ID �,r;1°W°50010 2151 COTTONWOOD ROAD P�, .DDI:.Ialm ,6vMP6 q FFEF & M E N K .,.:WE °° GRADING&STORM SEWER i i i 1 yy'.by, I P 1 ^� l_..wrL... I ]613 _ O I ❑ PROPOSED BUILDING ❑ I i M9)6]0 04 I 1`J„0 11°1 .LO 10 1 I 5 I I I 0 j s 1 I 1 I El El le 74-- i 7931 , , I I ' �'�° l ,p EL JAB �F3 ` •``_- 1°,�11Db '10� 10� \ CONCRETE OUT \ NI — — 975 ISWd -24 I \ SWAIE -� 9)6 1 I rN I— / CyNNEC]TODGSTNG INCAIR za 'Er- _ �srn9u¢FD[OxsmurnaN ENTRMlCE ,�>,,\ ,^ f` ` `CON[AETE WASNOUt a_y �` L R G` x J EG( COTTONWOOD ROAD E �- ' "" u SPCCLDEWANC a�• 1 IEGFND —SILTEENCE COMM _``--INUTPROTE 1P-yiµ` F%UTING MO S1�IlaE 10, PRDPOIEDCON]OURS P — \ ,�/ t• DRAINAGE ROW ARROW n AA•••• A INTERSECTION DETAIL ' \ xoTe Ipp •y S G ALL EIEVATIONSPO—MDEUNlESSOTN SENOTED 1 Q •..woE,w�.....�.w.�.�+...nw�.lu ISBOLTO PI Pn4AND.wvA14444 '^ uss�wN HUNZIKER DEVELOPMENT CO. E® & MENK na'Dnlmslm °G 2351 COTTONWOOD ROAD 5 @ro .m� .A...mnmm.�E� GRADING&STORM SEWER d I I sWavetk�" a•mm. atll�m PaP I r sieadledloa•e 3ome sr Ia / A \CURB WITH SIDEWALK DETAIL(SUDA57030.202) J6 N 30 R I — S PUE — _ _ _ — — — — — — — — Y. � n• s• n• ccL I I d G00 d07.n 6 STALL GARAGE 6 STALL GARAGE 1584 SF 1584 SF ——————————— —————— --- xs•eunDlx srreau43 — cc J— � I � � usEnlwr � f ' > — 14 .i — G — Q. F 'INIE l •d �6'BEGRAI CCVRD I I I d W X I X d 20DNCAETESTEPS - � I N WRN MIDNGRRER J'PCCSRIEWALII I C• y N L - I d 3CONUiE1E SRR O o I d WIIN W TRFAPAml.NwG-ER I 6L68' I SVSANR RY SEW ER EASEMENT ate\ �n C .3' LEGEND: Ig e9A1• ROADWAY.7°PCC(SEE DETAILA.7) to .❑ /❑ ? 1 tP PARKING.6'PCC(SEE DETAIL lL2) I ❑ ❑ �;. �� I SIDEWAIKS.4'PCC(SEEDETAILC.7) ( I3'1PFAD STEPS CUR PAL Vi> I I S L7 F eammee PorWng PmNded i PROPOSED BUILDING rnrscn Y,N I i e lag cc SIaN 3G Numbn tiibgaaWad Garagar 13 I ® � a.01 -1 �I UJO Mam I 1 Bad 0 6 Total 3p I ❑ InP'InIY ❑ n I I xandiupgnW i! �g 3bd a ie i ❑ PAMNRJbMNA -.. }/ 3md D p RepWrM 1 PARKINGGI ID RJ BB x Qii n RPNded i I ❑ VAN ACLESSIBIE SIGN ❑ 9 Van Acaslble } I �I1-1777 IS BOLTON n,PneoxEu wsywu HUNZ51 COTI NWO DROADMENT CO. * �senc Ruwn smlo 2151 COTTONWOOD ROAD ® & M E N K a�PIg15,i33e,m IgsneDG 6 v.•s IFT pEONonaeNm� ��u�� PARKING LAYOUT 4 f i i i I I I TPCC SIDEWAD( ' I I z4• �( I 1 I 3NNCGETE GTEPG •Y x CDN[aEIE STEPS " I ss•TGDID,raGEG lx•TRDID,c NSEa _ I 3 I u 1V SRNRP YSEWER FAGEMFM El Ell T /1 b ib ❑ CIRNfBEGGPL cc El J I ❑ oyy t o J I 3CONCRETESTEPS 2 NSF I Ep", i 11•TGEAD I 86 I PROPOSED BUILDING rnisEn ziN i I NG0.1 D P .aw, L I ❑ B aw, ❑ ^�'� /^cc I ❑ lrrs ir. I—le 1 I.L I ❑ PA N GBG NAND G2M N. -R WNDN I VANACCESSIBU:A. }. I so.Ra D v un -- I +, x Iaul IN SETBAa Jw- E CL $ B B•INEEGML O — — 1P PUE— — — — — — CUI10 — I Q s•vasEDEWAtK I 9 I` I1\ DROPNRQ j co L 5O G i W LEGEND: �R 0 ROADWAY.T PCC(SEE DE TAIL A.2) 1•fteEiw —Oj ❑ PARKING.6•PCC(SEE DETAIL 112) 6• `BWRABIk - ,S—4E'mm I EW ❑ SIDEWALKS.4°PED(SEE DETAIL G2) sR�Ba•exam ,.....r... Ea I- }4-Ai A CURB V4"SIDEWALK DETAIL SUDAS 7030.202 I_ Q , - - - - - - - BBOLTON .ME N 000� NUNMER DEVELOPMENT CO. MENK r1;�Mc=.j IBVMa 2151 COTTONWOOD ROAD u7 SGIE FT ..wea®rnw.n�imn� PARKING LAYOUT I i I I Attachment B: Major Site Development Plan (Utilities) e, F �l ) 6 ? NOO'45'S9'W 191.a1' O/ 1 N DO'45' 'W MAY a y m ————————————— t �n N00'45'S8'W37%5' ❑❑❑ ❑❑❑ ROM 30 m� 1. zo ;Kz -I EIEIO r i Nz N ——————————————— ————————————— — G m a a � ON W N'OOP E 190.50' I`: e"f•�. 00 18 Attachment B: Major Site Development Plan (Utilities) -i d 3 �� o N W45'a'w I� I I I I I I I I I I 6gS ❑ ❑ El El I o f z I e I o I� I Rom 3®Mq 9 m� w ' z0 y I I � h I F5 NI I a enE li I i I zq i � I � I u NG_ I ---------- ------------- � x g a E[!'9AN NW N'N'E 190.3W II 19 Attachment B: Major Site Development Plan (Landscaping) Nn NO 0o D I- v�� v vzvv� nm 5 m= p0 m V m z aSD aQD�zpz F� A-i a,ym Z=> gg5y'7A N m N A _ N ZOO{ C C DCCZ G) FAD1- m n Z O 0 Q G �sdd {Q Z r NIw�r1 to ,n"'IA 0 0 7J 34� O A D z m C N F+D t^r 2 G 0 5 m Fm Q V 01D `{W/1��QNOD m H Z F z T V lTC tp 7JT 0� m m m {Z O m m{\O Z $g m O Z A D pG1 O� P Z O tmil0 ~ ZO�tnAG1 D D t;O,it N r Gl t+ m ;. C rn not�Z.o! 5 G r II NA O Z y ♦N.i FM � � O m1O Cow N II p rn O H to Z W O N N Y I I { � I ♦ fi w W I _ 30 m6izo I Iw f F (3 V G)lCk y 6 . 97 �.s F t 1 1,9 N N Zso I � I o —D—� M 0 1 I I I 20 Attachment B: Major Site Development Plan (Landscape Details) Fs oig R H 05 Fa^ o Ila lit[ e Qs35 �x 4 g �n 7� "�y� ym u kip �'y. �i O y{eIF %qs�� I Hai $g3 a°2g i3 wo= RI WHO �• 5m o �o%m p ��'s � gg 3 � � _° �o5og� �a � �g� E �m sss aaa•aa GGGGG s" URN—. � �6T z �� Ili HIM PPS �P YGST HE NEIGfR .�i'i _ s E• GRE amNEIGHf Raw -1 `. m O W3 F ZO4 7CZ � � �° o ��}a � •W°• 3 s l F a � a � � o =�d 3 zlet�i o �� fiss� N r JS a 9 so ° F.l N a 21 Attachment C: Building Elevations Cover Sheet t,9�'n�ae•pFFGFOFFBYEaF�F"FFFRYaPpFR��"1Re°°�FpFR,'.CfeB°9°FY^�o-•s-a®Y�."9�F�bC�eHBF9&"c�c^$FLRi°PBFS[e�R•ce���9���RBHHh �HHP�BF@�FFae5���6e8°@FAR°� . tE°°° ap° 3R EEE ° Es � ®egg @ Es°aag a a��gi',@gge �oEE� ggaa a :Eg� 5ge gene H W i E v§ SEe °a ° � eiH.I ��il° F � � a°ZaHaAg°a°"gg9FFFPg"Aaeg:�g�ag�gHpaag�"gaA"etpF;=■Fa9P°g@i°s®•Hg'ag°ega"aagHFpF e P g i g gB�g �9�caF�e Eg pg@$1111011sal11@gEglE11g3gt6liE e�i1 allHgEaEeijg qMEN 9�� � �ae sgi► eases ��������g9 t�;t e G t N : cm = m y i o = s � m z N FF m a ■ e _-------- HUNZIKER APARTMENTS-72 PLEX oa¢ _ ____ -__ .k",.�" ate,. as H^��•I 22 Attachment C: Building Elevations , �YAk dtg !1roi. i��t LPti , rrk'4 Jib @° is II I$�(1 �lil �® —_ — I a--1-1 - 85�� lox I I CV MI Ir pilla F jjq kk ° MHL t tl7 h '�I qq ?� (ai t 7I /(�i� •• i� a I �= s -- -- �� . /wF r't I—r a F41 f3 F �I I e s ;aic 'e I I jai {�I I' r P1 P��.I I _ �e�eI g 7� I�Bp� I' Fx � i � f 413kt 14.4 <.4 PliP II 1 Ij �l @ H� NZIKER APARTMENTS-12 PLEX _� 1 s _ 23 Attachment D: Garage Elevations 'Coll co I Ili I I' I I'lll IIIII ,'I II II Ill II I ii rri Ijp rri Id M CD 0 CA I T—I3c: I�it I I II. it v I I I� + � i I I I I'I ' li !. III CO M rri 24 Attachment E: Floor Plans (First Floor) 0 is 01 AIR Fs �o22 !S E. a:8 c 8 EP4e — 1-- ---- - - s a r. o 0 - - -1 - o 0 0 CC ID "'" - --- 01 - Tjkill —111 do P� as L.—— ............ — —— — —_._. e --- _ : HIE va RE FA--W�- S0 � 0 --- - ------- 01 rg c� v F was Ft APARTMENTS-12 PLEX ,.�.�...rm...rs.�.�. I �¢g 25 Attachment E: Floor Plans (Second Floor) gig lit Saxe a9 xc;p �e oa 8s �$, A e x e° e• ° � �e�4 ��� m� I� � f� �e �e o —.—.—.—._._. _._. I�rr�`yyq�` : ------- --- o:l : a of _- x 3 S a ----o-- .a I � I -- — — ® ® I _ I U U - — I I HUNZIKER APARTMENTS-12 PLEX 1�-�;!yll •I 26 d � Attachment F: Village Park Subdivision and Landscape Plan o l o --=Tr I 1 �O�M'/OOD ALRESy1tC \ �J o 71 1, II III III 1 I IIIII� ii, ! I III illy f I'�%YI � ��Il .III I I r $ i FF- 1 III�4�1r' I � !..I�/I� 1`:,' I I l% I`\•'' II',. ~........... � ... ;III II,. I i .I I �''I.�.1.I � a.........it I ,I!,� %•f+'l O 'I 4 .... 10 '' -- -- , �yy e t 4 I q e..r °l�j Y 11 fl t _ 'Y it [[1_ f I I t III 'I! t e n v' � � ' ., � `\ �.• �.g,h , 1 ill I,. i II,!�m � C^ y ! \ II � \, •,;Y �1 1 III 21�A ,��!i, A •RCei • `_..\��` 1 ,\ ; `I !t `l_' •\ � I I � N i 9 �S\t �\ aq .. F+ LCNDSWINNGFI- y i E"a^�^o�°° • an' ®/� �usam lM enoel&Ybi o a. TI C p 3291 IXUv1A511'I, µ'ww W MG3s61 rtom000 en ineerin �A01�61 9 9 FAX I51�2901001�U1 27