HomeMy WebLinkAboutA040 - Letter to Mayor and Council dated December 13, 2012 - reducing Letter of credit to $21,500 Ames
Smart Choice
Public Works Department
515 Clark Avenue, Ames, Iowa 50010
Phone 515-239-5160 ♦ Fax 515-239-5404
December 13, 2012
Honorable Mayor and Council Members
City of Ames
Ames, Iowa 50010
Ladies and Gentlemen:
I hereby certify that the utilities and paving required as a condition for approval of the final
plat of South Fork, 3rd Addition has been completed in an acceptable manner by Ames
Trenching & Excavating of Ames, IA and Manatts, Inc. of Ames, IA. The above-mentioned
improvements have been inspected by the Engineering Division of the Public Works
Department of the City of Ames, Iowa and found to meet City specifications and standards.
As a result of this certification, it is recommended that the financial security for public
improvements on file with the City for this subdivision be set at $21,500. The remaining work
covered by this financial security includes asphalt surface, pedestrian sidewalk ramps, and final
fixture adjustments.
Sincerely,
John C.Joiner, P.E.
Director
JJ/jc
cc: Finance, Contractor, Construction Supervisor, PW Senior Clerk, Planning & Housing,
Subdivision file
Public Works Department 515.239.5160 ..i,, 515 Clark Ave.P.O.Box 811
Engineering
515.239.5404 /ax Ames,IA 50010
t
South Fork, 3 d Addition
December 13, 2012
Page 2
Description Unit Quantity
Class 13 Excavation CY 1400
Sub-grade Preparation SY 2520
4"Sanitary Sewer Service (8" or 10"Saddle Connection) EA 8
Storm Sewer,Trenched, 18" LF 152
Storm Sewer,Trenched, 24" LF 114
Footing Drain Collector, 8" LF 345
Footing Drain Cleanout EA 1
Footing Drain Outlet and Connection,8" EA 3
Storm Sewer Service Stub, PVC, 1-1/2" EA 8
Water main,Trenched, PVC, SDR18,8" LF 640
Water Service Connection, Curb Stop& Box, 1" EA 8
Gate Valve& Box, 8" EA 2
8" MJ Tee EA 1
Fire Hydrant Assembly EA 1
Remove and Relocate Hydrant Assembly EA 1
Intake,Type SW-502 EA 4
Pipe Apron, 24" RCP W/Guard and Footing EA 1
Manhole/Intake Adjustment, Minor EA 2
Manhole/Intake Adjustment, Major EA 2
Silt Fence-Install, Maint. & Removal LF 400
Seeding,Type 1 Lawn Mix ACRE 4
Inlet Protection Device-Install, Maint. & Removal EA 6
Sidewalk, 6" PCC SY 55
Truncated Domes SF 32
Pavement, HMA, 8"-Beedle SY 670
Pavement, HMA, 9.5"-Cochrane SY 1185
30" PCC Curb and Gutter LF 1335