HomeMy WebLinkAboutA020 - Letter certifying completion of utilities and street construction dated May 7, 2010 1 asr>
Public Works Department
515 Clark Avenue, Ames, Iowa 50010
Phone 515-239-5160
Fax 515-239-5404
c{ ig People y.
Qiauhy Program
Erceptional Service
May 7, 2010
Honorable Mayor and Council Members
City of Ames
Ames, Iowa 50010
Ladies and Gentlemen:
hereby certify that the utilities and street construction required as a condition for
approval of the final plat of Estates West 1st Addition has been completed in an
acceptable manner by Halbrook Excavating. The above-mentioned improvements have
been inspected by the Engineering Division of the Public Works Department of the City
of Ames, Iowa and found to meet City Specifications and Standards.
As a result of this certification, it is recommended that the financial security for public
improvements on file with the City for this subdivision be released in full.
Sincerely,
a
t
Tracy L. Warner, P.E.
Municipal Engineer
Acting Public Works Director
City of Ames
TW/ec
cc: Finance, Contractor, PW Admin Asst, Construction Supervisor, Planning &
Housing
Estates West 1st Addition 2
May 7, 2010
Destr~ tion Unit Quantit
Excavation and Embankment CY 8,800
Clearing and Grubbing LS 1
Silt Fence LF 2,000
Inlet Protection EA 11
Stabilized Construction Entrance EA 1
Straw Mulch ACRE 5
Seeding, Type 5 Stabilizing Crop ACRE 5
8-inch Sanitary Sewer LF 831
48-inch Dia. Sanitary Manhole (A) EA 5
4-inch Sanitary Service EA 11
8-inch Water Main LF 887
8-inch 11.25 Degree M.J. Bend EA 2
8-inch 45 Degree M.J. Bend EA 1
16"x8" Tapping Valve and Sleeve EA 1
8"x6"M.J. Reducer EA 1
8-inch M.J. Gate Valve EA 1
Hydrant and Hydrant Run (includes 8"x8"x6" M.J.
Tee, 6" M.J. Gate Valve, 6" Pipe and Hydrant) EA 2
1-inch Water Service EA 11
Rip Rap, Class 'D' TON 5
6-inch Collector Line LF 99
15-inch RCP, Class III LF 748
18-inch RCP, Class III LF 148
24-inch RCP, Class III LF 59
24-inch F.E.S. EA 1
Storm Sewer Manhole (Sanitary T pe 'A') EA 1
Storm Sewer Intake (M-A) EA 1
Storm Sewer Intake (M-C) EA 1
Storm Sewer Intake (M-D) EA 4
Storm Sewer Intake (M-E) EA 4
RCP Area Intake, 24" Dia EA 1
Collector Line Cleanout EA 1
1.5-inch Sump Service EA 11
Subgrade Preparation SY 4,131
30-inch P.C.C. Curb and Gutter LF 2,071
6-inch P.C.C. Pedestrian Ramp SY 46
Detectable Warning Material SF 32
8-inch H.M.A. Pavement SY 3,027