HomeMy WebLinkAbout~Master - Amending Chapter 28 of Municipal Code; Allowing for Plastic Plumbing Pipes ORDINANCE NO. 2484 AN ORDINANCE AMENDING CHAPTER #28 OF THE MUNIiCIPAL CODE OF THE CITY OF AMES , IOWA; REPEALING TABLE 9 . 9 AND REPEALING SECTIONS 28-1013 . 4 , 28-1033 . 1, 28-1061 , 28-1067 . 1 , 28-1067 . 2 , 28-1067 . 4 , AND 28-1076 . 2 ; ESTABLISHING A NEW TABLE 9 . 9 AND NEW SECTIONS 28-1013 . 4 , 28-1033 . 1, 28-1061, 28-1067. 1, 28-1067 . 2 28-1067 . 4 , 28-1076 . 2 ; ALLOWING FOR PLASTIC PLUMBING PIPES ;. REPEALING ALL ORDINANCES OR PARTS OF ORDINANCES IN CONFLICT HEREWITH AND ESTABLISHING AN EFFECTIVE DATE. IT IS ORDAINED BY THE CITY COUNCIL OF THE CITY OF AMES, IOWA: Section 1. Table 9 . 9 of Chapter 28 and Sections 28-1013. 4 , 28-1033 . 1 , 28-1061 , 28-1067 . 1, 28-1067 . 2 , 28-1067. 4 , 28-1076 . 2 of the Municipal Code of the City of Ames , Iowa, as heretofore existing are hereby repealed. Section 2 . A new table 9 . 9 of Chapter 28 and new Sections 28-1013 . 4 , 28-1033. 1 , 28-1061 , 28-1067. 1 , 28-1067. 2 , 28-1067 . 4 , and 28-1076 . 2 are hereby adopted to read as follows : TABLE 9 . 9 MATERIALS FOR PLUMBING INSTALLATIONS See Sections 28-1009 . 1 and 28-1009 . 2 OTHER STANDARDS MATERIALS ASA ASTM FS REMARKS NONMETALLIC PIPING Clay Sewer Pipe and Fittings -- -- SS-P-361D-1968 Standard Strength Clay Sewer Pipe A106 . 3-67 C13-69 SS-P-361D-1968 Extra Strength Clay Sewer Pipe -- C200-69 SS-P-361D-1968 Clay Pipe Perforated A106 . 1-69 C211-68 SS-P-359B-1960 CS143-60 Clay Drain Tile A6 . 1-63 C4-62 Concrete Sewer Pipe C76-70 SS-P-375D-1970 Reinforced Concrete Sewer Pipe C14-70 Plastic Water Pipe & Fittings , P .E. Series 2 & 3 B72 . 1-67 D2239-69 PS11-69 nSf Plastic Water Pipe & Fittings , Rigid ABS B72. 3-67 D2282-69a PS19-69 nSf Plastic Water Pipe & Fittings , Rigid PVC B72 . 2-67 D2241-69 PS22-70 nSf Plastic Pipe & Fittings ABS Schedule 40 (DWV) Drainage, Waste & Vent D2661-68 LP-322A-1966 UPC IS-5 Plastic Pipe & Fittings PVC Schedule 40 Schedule 40 (DWV) Drainage Waste & Vent D2665-68 LP-320A-1966 UPC IS-9 Plastic Sewer Pipe & Fittings Styrene Rubber CS228-61 FERROUS PIPE AND FITTINGS Cast Iron Soil Pipe & Fittings A112 . 5 . 1-1971 A74-69 WW-P-401D-1969 CS188-66 Cast Iron Water Pipe A21. 6-1970 WW-P-241C-1967 ATIWA-C106-1970 7- /o- 7� TABLE 9 . 9 MATERIALS FOR PLUMBING I STALLATIONS (CONT. ) OTHER STANDARDS MATERIALS ASA ASTM FS REMARKS Cast Iron (Threaded) Pipe A40. 5-1943 WW-P-356-1936 Cast Iron (Screwed) Fittings B16 . 4-1971 WW-P-501D-1967 Cast Iron Drainage Fittings B16. 12-1971 WW-P-491B-1967 Galvanized Pipe & Fittings WW-P-406C-1969 Wrought Iron Pipe (Welded) B36 . 2-1969 A72-68 Steel Pipe (Seamless & Welded) Black and Hot B125. 2-1970 A120-69 WW-P-406C-1969 Dipped Zinc Coated (Galvanized) Malleable Iron Fittings (Threaded) 150 lbs. B16 . 3-1971 WW-P-521F-1968 Unions , Malleable- Iron or Steel 300 lbs . CS7-29 Valves , Cast Iron Gate 125 & 250 lbs . WW-V-58B-1971 Ferrous Bushings , Plugs & Lock Nuts (Threaded) WW-P-471B-1970 Nipples Pipe , Threaded WW-N-351B (1) -1970 CS5-65 NONFERROUS PIPE & FITTINGS Nonferrous Bushings , Plugs & Lock Nuts (Threaded) WW-P-471B-1970 CS5-65 Brass Tubing, Seamless H36. 1-1969 B135-71a WW-T-791 (1) -1933 Brass Pipe Seamless , Red H27. 1-1967 B43-70 WW-P-351A-1963 Brass or Bronz Flanged Fittings 150 & 300 lbs . B16. 24-1971 Cast Bronze Solder- Joint Fittings B16-18-1963 for Water Tube (Addenda (a) 1967) Brass or Bronze Screwed Fittings 125 & 250 lbs . B16 . 15-1971 WW-P-460B-1967 Copper Pipe- Seamless H26 . 1-1967 B42-70 WW-P-377D-1962 Copper Tube- Seamless H23 . 3-1970 B75-68 WW-T-797C-1963 Copper Pipe- Threadless H26 . 2-1967 B302-70 Copper Water Tube , Types K , L, M H23. 1-1970 B88-71 WW-T-799C-1967 Wrought Copper and Bronze Solder Joint Pressure Fittings B16 . 22-1963 Cast Bronze Fittings for Flared Copper Tubes B16. 26-1967 Copper Drainage Tube, Type DV7V H23. 6-1967 B306-71b CS229-60 Valves , Bronze: Angle Check & Globe , 125 & 150 lbs . , Threaded & Flanged WW-V-51D-1967 -2- 7- ) 0 _ 7 � Sec. 28-1013 . 4. Same--Fixture connections to drainage pipes . Fixture connections between drainage pipes and water closets , floor-outlet service sinks , pedestal urinals , and earthenware trap standards , shall be made by means of brass , or iron flanges , caulked, soldered, or screwed to the drainage pipe. The connection shall be bolted, with an approved gasket or washer or setting compound between the earthenware and the connection. The floor flange shall be set on an approved form base. The use of commercial putty or plaster is prohibited. Plastic flanges may also be used when specifically permitted in other sections of this code. Sec. 28-1033. 1. Same--Connections . (a) Lead. Three (3) inch lead bends and stubs may be used on water closets or similar connections , provided the inlet is dress or expanded to receive a four inch flange. (b) Reducing. Four (4) by three (3) inch reducing bends are permitted. Sec. 28-1061. Pipes and tubing materials . Materials for water distribution pipes and tubing shall be of brass , copper, lead, cast iron. (See Table 9 .9 for standards) All threaded ferrous pipe and fittings shall have been galvanized (zinc coated) or cement lined, and when such pipe and fittings are used underground inside buildings, they shall be coal tar enamel coated and the threaded joints wrapped at the time of installation. Type K copper may be used under and above ground. Type L may be used above ground only. Copper pipe and tubing shall be installed such that the color marking is clearly visible at the time of inspection. Plastic pipe and fittings marked to show approval by the National Sanitation Foundation Testing Laboratory and having properties suitable for the purpose intended may be used underground outside of any structure for cold water purposes , including sprinkler systems serving lawns , golf courses , and similar installations . Provisions shall be made to accommodate the rate of expansion and contraction in plastic pipe being approximately ten times greater than that found in copper pipe. Flexible plastic pipe shall be laid in snake fashion to provide a uniform slack of at least two (2) inches per one hundred (100) feet. Plastic pipe shall not be jacked or pulled. Sec. 28-1067. 1. Above ground piping within buildings . Soil and waste piping for a drainage system within a building shall be of cast iron, galvanized wrought iron, galvanized open-hearth iron, galvanized steel , lead, brass , seamless copper pipe , or copper tube, types DWV, K, L, M, or plastic. Seamless copper pipe or copper tubes, types K, L, M, may be used in all buildings . Copper tube Type DWV may be used in single or two family dwellings provided that copper tube has proven to be a suitable material resistant to corro- sion in the locality where used. All copper pipes and tubes shall be installed so that the color marking is clearly visible at the time of inspection on the full length of each pipe installed. -3- 7-i Plastic pipe and fittings; except fixture traps marked to show conformance with ASTM Designations D2661-68 or D2665-68 or current issued thereof, and standard No. 14 of the National Sanitation Foundation Testing Laboratory; may be used in buildings not exceeding two stories in height under the following conditions . (a) No vertical stack shall exceed thirty-five (35) feet in height. No horizontal branch shall exceed fifteen (15) feet in length. (b) All installations shall be made in accordance with recommendations of the manufacturer when found specifically conforming with other sections of these rules in the installation procedures appearing in the appendix of the applicable ASTM standard. (c) ABS Plastic, exposed to sunlight, shall be protected by water base synthetic latex paints . Where surface temperatures exceed 165°F, piping shall be protected by means of shielding or some type of light- weight insulation. PVC Plastic, except vent piping through roofs, shall not be installed so as to be subject to direct sunlight after installation. Where surface temperatures exceed 140°F, piping shall be protected by means of shielding or some type of light weight insulation. (d) A variance in application of these materials may be allowed by the administrative authority in a particular case when specifically certified as warranted by a professional engineer. Sec. 28-1067. 2 . Underground piping within buildings . Drains within buildings when underground shall be of cast iron, lead, or seamless copper pipe or copper tube Types K or L. All copper pipe and tube shall be installed so that the color marking is clearly visible at the time of inspection on the full length of each piece installed. Sec. 28-1067 .4. Concealed waste pipes. Concealed waste pipes shall be of lead, brass , copper, plastic, or cast iron soil pipe up to and including the fixture opening. Galvanized may be used in accessible pipe chases where maintenance can be performed without cutting construction members . Sec. 28-1076 . 2 . Above ground piping. Vent piping above ground shall be of cast iron, gal- vanized wrought iron, galvanized ferrous alloys, lead, brass , seamless copper pipe or copper tube or plastic. Galvanized steel may be used in buildings of four (4) stories or less. Seamless copper pipe or copper tube types K, L, and M may be used in all buildings. Copper tube Type DWV may be used in single or two family dwellings provided that copper has proven to be a suitable material resistant to corrosion in the locality where used. All copper pipe and tube shall be installed so that the color marking is clearly visible at the time of inspection on the full length of each piece installed. Plastic pipe and fittings marked to show conformance with ASTM Designation D2665-68 or current issue thereof and standard number 14 of the National Sanitation -4- 7- /o- '74 Foundation Testing Laboratory may be used in buildings not exceeding two (2) stories in height under the following conditions : (a) No vertical stack shall exceed thirty-five (35) feet in height. (b) All installations shall be made in accordance with recommendations of the manufacturer when found specifically conforming with other sections of these rules in the installation procedures appearing in the appendix of the applicable ASTM standard. (c) ABS Plastic , exposed to sunlight, shall be protected by water base synthetic latex paints . Where surface temperatures exceed 165°F , piping shall be protected by means of shielding or some type of lightweight insulation. (d) A variance in application of these materials may be allowed by the administrative authority in a particular case when specifically certified as warranted by a professional engineer. Section 3 . All ordinances and parts of ordinances in conflict herewith are hereby repealed. Section 4. This ordinance is in full force and effect from and after its passage and publication as provided by law. Passed this 6th day of August 1974. 4 e'X � �. Mary E. Pa6l , City Clerk William F. Pelz , MaydI lst Reading 7/16/74 (Maxwell-Koerber) Ayes : Calhoun, Maxwell, Huston, Nelson, Pounds, Koerber. Nays : None 2nd Reading 7/23/74 (Pounds-Maxwell) Ayes: Maxwell, Huston, Nelson, Pounds, Koerber Nays : None Absent: Calhoun 3rd Reading 8/6/74 (Maxwell-Nelson) Ayes: Calhoun, Maxwell, Huston, Nelson, Pounds, Koerber Nays : None -5- 7-�o-7l+�