HomeMy WebLinkAbout~Master - Amending Chapter 28 of Municipal Code; Allowing for Plastic Plumbing Pipes ORDINANCE NO. 2484
AN ORDINANCE AMENDING CHAPTER #28 OF THE MUNIiCIPAL CODE OF THE CITY OF AMES ,
IOWA; REPEALING TABLE 9 . 9 AND REPEALING SECTIONS 28-1013 . 4 , 28-1033 . 1,
28-1061 , 28-1067 . 1 , 28-1067 . 2 , 28-1067 . 4 , AND 28-1076 . 2 ; ESTABLISHING A NEW
TABLE 9 . 9 AND NEW SECTIONS 28-1013 . 4 , 28-1033 . 1, 28-1061, 28-1067. 1, 28-1067 . 2
28-1067 . 4 , 28-1076 . 2 ; ALLOWING FOR PLASTIC PLUMBING PIPES ;. REPEALING
ALL ORDINANCES OR PARTS OF ORDINANCES IN CONFLICT HEREWITH AND ESTABLISHING
AN EFFECTIVE DATE.
IT IS ORDAINED BY THE CITY COUNCIL OF THE CITY OF AMES, IOWA:
Section 1. Table 9 . 9 of Chapter 28 and Sections 28-1013. 4 ,
28-1033 . 1 , 28-1061 , 28-1067 . 1, 28-1067 . 2 , 28-1067. 4 , 28-1076 . 2 of the
Municipal Code of the City of Ames , Iowa, as heretofore existing are hereby
repealed.
Section 2 . A new table 9 . 9 of Chapter 28 and new Sections
28-1013 . 4 , 28-1033. 1 , 28-1061 , 28-1067. 1 , 28-1067. 2 , 28-1067 . 4 , and 28-1076 . 2
are hereby adopted to read as follows :
TABLE 9 . 9 MATERIALS FOR PLUMBING INSTALLATIONS
See Sections 28-1009 . 1 and 28-1009 . 2
OTHER
STANDARDS
MATERIALS ASA ASTM FS REMARKS
NONMETALLIC PIPING
Clay Sewer Pipe and
Fittings -- -- SS-P-361D-1968
Standard Strength
Clay Sewer Pipe A106 . 3-67 C13-69 SS-P-361D-1968
Extra Strength Clay
Sewer Pipe -- C200-69 SS-P-361D-1968
Clay Pipe Perforated A106 . 1-69 C211-68 SS-P-359B-1960 CS143-60
Clay Drain Tile A6 . 1-63 C4-62
Concrete Sewer Pipe C76-70 SS-P-375D-1970 Reinforced
Concrete Sewer Pipe C14-70
Plastic Water Pipe
& Fittings , P .E.
Series 2 & 3 B72 . 1-67 D2239-69 PS11-69 nSf
Plastic Water Pipe
& Fittings ,
Rigid ABS B72. 3-67 D2282-69a PS19-69 nSf
Plastic Water Pipe
& Fittings ,
Rigid PVC B72 . 2-67 D2241-69 PS22-70 nSf
Plastic Pipe &
Fittings ABS
Schedule 40
(DWV) Drainage,
Waste & Vent D2661-68 LP-322A-1966 UPC IS-5
Plastic Pipe &
Fittings PVC
Schedule 40
Schedule 40
(DWV) Drainage
Waste & Vent D2665-68 LP-320A-1966 UPC IS-9
Plastic Sewer Pipe
& Fittings
Styrene Rubber CS228-61
FERROUS PIPE AND
FITTINGS
Cast Iron Soil Pipe
& Fittings A112 . 5 . 1-1971 A74-69 WW-P-401D-1969 CS188-66
Cast Iron Water
Pipe A21. 6-1970 WW-P-241C-1967 ATIWA-C106-1970
7- /o- 7�
TABLE 9 . 9 MATERIALS FOR PLUMBING I STALLATIONS (CONT. )
OTHER
STANDARDS
MATERIALS ASA ASTM FS REMARKS
Cast Iron (Threaded)
Pipe A40. 5-1943 WW-P-356-1936
Cast Iron (Screwed)
Fittings B16 . 4-1971 WW-P-501D-1967
Cast Iron Drainage
Fittings B16. 12-1971 WW-P-491B-1967
Galvanized Pipe
& Fittings WW-P-406C-1969
Wrought Iron Pipe
(Welded) B36 . 2-1969 A72-68
Steel Pipe (Seamless
& Welded) Black and
Hot B125. 2-1970 A120-69 WW-P-406C-1969
Dipped Zinc
Coated (Galvanized)
Malleable Iron
Fittings (Threaded)
150 lbs. B16 . 3-1971 WW-P-521F-1968
Unions , Malleable-
Iron or Steel
300 lbs . CS7-29
Valves , Cast Iron
Gate 125 & 250 lbs . WW-V-58B-1971
Ferrous Bushings ,
Plugs & Lock Nuts
(Threaded) WW-P-471B-1970
Nipples Pipe ,
Threaded WW-N-351B (1) -1970 CS5-65
NONFERROUS PIPE &
FITTINGS
Nonferrous Bushings ,
Plugs & Lock Nuts
(Threaded) WW-P-471B-1970 CS5-65
Brass Tubing,
Seamless H36. 1-1969 B135-71a WW-T-791 (1) -1933
Brass Pipe
Seamless , Red H27. 1-1967 B43-70 WW-P-351A-1963
Brass or Bronz
Flanged Fittings
150 & 300 lbs . B16. 24-1971
Cast Bronze Solder-
Joint Fittings B16-18-1963
for Water Tube (Addenda (a) 1967)
Brass or Bronze
Screwed Fittings
125 & 250 lbs . B16 . 15-1971 WW-P-460B-1967
Copper Pipe-
Seamless H26 . 1-1967 B42-70 WW-P-377D-1962
Copper Tube-
Seamless H23 . 3-1970 B75-68 WW-T-797C-1963
Copper Pipe-
Threadless H26 . 2-1967 B302-70
Copper Water Tube ,
Types K , L, M H23. 1-1970 B88-71 WW-T-799C-1967
Wrought Copper and
Bronze Solder Joint
Pressure Fittings B16 . 22-1963
Cast Bronze Fittings
for Flared Copper
Tubes B16. 26-1967
Copper Drainage
Tube, Type DV7V H23. 6-1967 B306-71b CS229-60
Valves , Bronze: Angle
Check & Globe , 125
& 150 lbs . , Threaded
& Flanged WW-V-51D-1967
-2-
7- ) 0 _ 7 �
Sec. 28-1013 . 4. Same--Fixture connections to drainage
pipes .
Fixture connections between drainage pipes and water
closets , floor-outlet service sinks , pedestal urinals ,
and earthenware trap standards , shall be made by means
of brass , or iron flanges , caulked, soldered, or screwed
to the drainage pipe. The connection shall be bolted,
with an approved gasket or washer or setting compound
between the earthenware and the connection. The floor
flange shall be set on an approved form base. The use
of commercial putty or plaster is prohibited. Plastic
flanges may also be used when specifically permitted in
other sections of this code.
Sec. 28-1033. 1. Same--Connections .
(a) Lead. Three (3) inch lead bends and stubs may
be used on water closets or similar connections , provided
the inlet is dress or expanded to receive a four inch
flange.
(b) Reducing. Four (4) by three (3) inch reducing
bends are permitted.
Sec. 28-1061. Pipes and tubing materials .
Materials for water distribution pipes and tubing
shall be of brass , copper, lead, cast iron. (See Table
9 .9 for standards) All threaded ferrous pipe and fittings
shall have been galvanized (zinc coated) or cement lined,
and when such pipe and fittings are used underground
inside buildings, they shall be coal tar enamel coated
and the threaded joints wrapped at the time of installation.
Type K copper may be used under and above ground. Type L
may be used above ground only. Copper pipe and tubing
shall be installed such that the color marking is clearly
visible at the time of inspection.
Plastic pipe and fittings marked to show approval by
the National Sanitation Foundation Testing Laboratory and
having properties suitable for the purpose intended may
be used underground outside of any structure for cold
water purposes , including sprinkler systems serving
lawns , golf courses , and similar installations . Provisions
shall be made to accommodate the rate of expansion and
contraction in plastic pipe being approximately ten times
greater than that found in copper pipe. Flexible plastic
pipe shall be laid in snake fashion to provide a uniform
slack of at least two (2) inches per one hundred (100)
feet. Plastic pipe shall not be jacked or pulled.
Sec. 28-1067. 1. Above ground piping within buildings .
Soil and waste piping for a drainage system within a
building shall be of cast iron, galvanized wrought iron,
galvanized open-hearth iron, galvanized steel , lead,
brass , seamless copper pipe , or copper tube, types DWV,
K, L, M, or plastic.
Seamless copper pipe or copper tubes, types K, L, M,
may be used in all buildings . Copper tube Type DWV may be
used in single or two family dwellings provided that copper
tube has proven to be a suitable material resistant to corro-
sion in the locality where used. All copper pipes and tubes
shall be installed so that the color marking is clearly
visible at the time of inspection on the full length of
each pipe installed.
-3-
7-i
Plastic pipe and fittings; except fixture traps marked
to show conformance with ASTM Designations D2661-68 or
D2665-68 or current issued thereof, and standard No. 14
of the National Sanitation Foundation Testing Laboratory;
may be used in buildings not exceeding two stories in
height under the following conditions .
(a) No vertical stack shall exceed thirty-five
(35) feet in height. No horizontal branch shall exceed
fifteen (15) feet in length.
(b) All installations shall be made in accordance
with recommendations of the manufacturer when found
specifically conforming with other sections of these rules
in the installation procedures appearing in the appendix
of the applicable ASTM standard.
(c) ABS Plastic, exposed to sunlight, shall be
protected by water base synthetic latex paints . Where
surface temperatures exceed 165°F, piping shall be
protected by means of shielding or some type of light-
weight insulation.
PVC Plastic, except vent piping through roofs, shall
not be installed so as to be subject to direct sunlight
after installation. Where surface temperatures exceed
140°F, piping shall be protected by means of shielding or
some type of light weight insulation.
(d) A variance in application of these materials
may be allowed by the administrative authority in a
particular case when specifically certified as warranted
by a professional engineer.
Sec. 28-1067. 2 . Underground piping within buildings .
Drains within buildings when underground shall be of cast
iron, lead, or seamless copper pipe or copper tube Types
K or L. All copper pipe and tube shall be installed so
that the color marking is clearly visible at the time of
inspection on the full length of each piece installed.
Sec. 28-1067 .4. Concealed waste pipes.
Concealed waste pipes shall be of lead, brass , copper,
plastic, or cast iron soil pipe up to and including the
fixture opening.
Galvanized may be used in accessible pipe chases where
maintenance can be performed without cutting construction
members .
Sec. 28-1076 . 2 . Above ground piping.
Vent piping above ground shall be of cast iron, gal-
vanized wrought iron, galvanized ferrous alloys, lead, brass ,
seamless copper pipe or copper tube or plastic. Galvanized
steel may be used in buildings of four (4) stories or less.
Seamless copper pipe or copper tube types K, L, and M
may be used in all buildings. Copper tube Type DWV may be
used in single or two family dwellings provided that copper
has proven to be a suitable material resistant to corrosion
in the locality where used. All copper pipe and tube shall
be installed so that the color marking is clearly visible
at the time of inspection on the full length of each piece
installed.
Plastic pipe and fittings marked to show conformance
with ASTM Designation D2665-68 or current issue thereof
and standard number 14 of the National Sanitation
-4-
7- /o- '74
Foundation Testing Laboratory may be used in buildings
not exceeding two (2) stories in height under the following
conditions :
(a) No vertical stack shall exceed thirty-five (35)
feet in height.
(b) All installations shall be made in accordance with
recommendations of the manufacturer when found specifically
conforming with other sections of these rules in the
installation procedures appearing in the appendix of the
applicable ASTM standard.
(c) ABS Plastic , exposed to sunlight, shall be protected
by water base synthetic latex paints . Where surface
temperatures exceed 165°F , piping shall be protected by
means of shielding or some type of lightweight insulation.
(d) A variance in application of these materials may be
allowed by the administrative authority in a particular
case when specifically certified as warranted by a
professional engineer.
Section 3 . All ordinances and parts of ordinances in conflict
herewith are hereby repealed.
Section 4. This ordinance is in full force and effect from and
after its passage and publication as provided by law.
Passed this 6th day of August 1974.
4 e'X
� �.
Mary E. Pa6l , City Clerk William F. Pelz , MaydI
lst Reading 7/16/74
(Maxwell-Koerber)
Ayes : Calhoun, Maxwell, Huston, Nelson, Pounds, Koerber.
Nays : None
2nd Reading 7/23/74
(Pounds-Maxwell)
Ayes: Maxwell, Huston, Nelson, Pounds, Koerber
Nays : None
Absent: Calhoun
3rd Reading 8/6/74
(Maxwell-Nelson)
Ayes: Calhoun, Maxwell, Huston, Nelson, Pounds, Koerber
Nays : None
-5- 7-�o-7l+�