HomeMy WebLinkAboutA021 - Letter from Union Pacific Railroad dated April 25, 2018 l'U zLY
�T
1_f
40
o-f
April 25,2018 bz GePLOe e f Pay-141A
Folder: 03094-18
NATHAN WILLEY
CITY OF AMES
CITY HALL, 515 CLARK AVENUE
AMES IA 50010
RE: Proposed New Installation of One 1 Underground Twelve 12 Inch Plastic Pipe Cased in a
P O g ( ) P
Twenty-Four(24)Inch Steel Pipeline crossing at Mile Post 186.11,on the Clinton Subdivision at or near
Ames, Story County, Iowa. This New Installation is Replacing Existing Pipeline Covered under Audit
205857 which will be abandone
d in place.
Nathan Willey:
This will acknowledge receipt of the following documentation relating to your intent to construct a
pipeline crossing under Union Pacific Railroad Company's tracks and right of way at Mile Post 186.11 on
the Clinton Subdivision,at or near Ames, Story County, Iowa:
Notice of Intent to construct
Specification Exhibit A
The$750.00 License Fee Required
You are required to comply with Iowa Code Section 476.27 and 199 IAC Chapter 42, including but not
limited to, providing Union Pacific Railroad Company with written notice at least ten days prior to your
commencing any construction, maintenance or repair of your facilities on Union Pacific's right of way.
Please,contact the following parties directly before commencing any work on Railroad property:
Railpros Flagging Jeremy A.Batterton
upflag@railprosfs.com ASST MGR SIGNAL MNTCE
(877)315-0513 x 116 Phone: 319-360-6899
jabatter@up.com
The Railroad Company has authorized the installation of fiber optic cable facilities on its property in
certain areas. Prior to commencing any work on the Railroad Company's property,you should contact the
Railroad Company at 1-800-336-9193 to determine if a fiber optic cable is buried on the subject
property.
If you have any questions,please contact me at(402)544-8571.
Telephone numbers are provided for your convenience,and not as a substitute for written notice.
Sincerely,
Adam ngel p
Real Estate tilities
Union Pacific Railroad Real Estate 1400 Douglas Street Stop 1690 Omaha,Nebraska 68179-1690 fx.(402)501-0340
NON-FLAMMABLE LIQUID OCROSSING
❑ ENCROACHMENT
PIPELINE ❑ BOTH
B UPRR R.0.W. _-
I
- 4716 FT. _ 564 F T.
r I �
0 526 F T. i =_ 21 F T. � L�
�Iw W �
CL I F —7
s m I Dk DEG. s r
¢ z I u ANGLE OF
- Z CROSSING
u - - - - - - - -
-----------� I o - - -------- - - - - - - - f- -
DESCRIBE a !" DESCRIBE
cr
FIXED OBJECT " I FIXED OBJECT
CROSSING TRACK CROSSING TRACK o
C/L of Br.552 ( E.Line of Sec.6(T83N,R23W)
NORTH (ES:5508+17) (ES:5502+70)
-----------------------------A� UPRR R.O.W.-------------------------
--
PLAN
SCALE: NONE
l i
�13
mjla OUTER OUTER alo
1� I TRACK TRACK :Dtcj
-57 FT. -i �-- -- ---61 FT.-- —�
267 F T. ------ -
I
- 61 FT. - 121 FT. 85 FT.--
VENT PIPE I 6 I
NA TOTAL TRACKS
- ' NA FT' I QU=FT, GROUND
FT. i SURFACE
DRAINAGE '
DITCH
I I
1 19.58FT. ' _FT.
5.5 F T.
- - - -- - - - - - - -- - - --- - - - - - - - - -
- - -
CASING PIPE SECTION
CARRIER PIPE SCALE: NONE LONGITUDINAL PIPE
ENCROACHMENT
NOTES:
1)ALL DIMENSIONS MEASURED PERPENDICULAR TO THE CENTERLINE OF TRACK
2 REFER TO AREMA VOLUME 1.CHAPTER 1.PART 5.SECTION 5.1
A) METHOD OF INSTALLATION BORED ANDJACKED
B) DIST.FROM CENTERLINE OF TRACK TO PIPE ENCROACHMENT BUILDING AMERICA*
C) SIGNS PROVIDED? AT MINIMUM SIGNS WILL BE PROVIDED AS STATED ABOVE
01 CARRIER MATERIAL PLASTIC . IF RCP,CLASS V? NA
COMMODITY TO BE CONVEYED POTABLEWATER
EXHIBIT "A"
OPERATIONAL PRESSURE 80 PSI. MAOP 80 PSI.
WALL THICKNESS (INCH)/ SCHEDULE 18 DIAMETER 12 IN. SUBDIVISION:Clinton Sub.
CATHODIC/COATING PROTECTION NO TRACK TYPE:MAINLINE
E) CASING MATERIAL STEELPIPE IF RCP,CLASS V? NA M.P.: 186.11
L A T.: 42.030142538251
TOTAL LENGTH CASING PIPE:26.E FT. E,S.M.:ssoz+sl LONG.: -s3.s5ea13ssazl
WALL THICKNESS 0.4375 IN. DIAMETER 24 IN.
CATHODIC/COATING PROTECTION NO NEAREST CITY: COUNTY: STATE:
CASING PIPE 1S OPEN AT THE ENDS. AMES __. STORY _. IA
F) DISTANCE FROM CENTERLINE OF TRACK TO NEAR FACE OF APPLICANT: CITYOFAMES
BORING AND JACKING PITS WHEN MEASURED AT RIGHT ANGLES
6_ AND 67 FILE NO.: 0309418 DATE: 04/2 012 0 1 8