Loading...
HomeMy WebLinkAboutA001 - Blackhawk Automatic Sprinklers proposal BLACKHAWK AUTOMATIC SPRINKLERS, INC. FIRE PROTECTION CONTRACTORS 0 DESIGN, INSTALLATION & MAINTENANCE P.O. BOX 1887 WATERLOO, IA 50704 TELEPHONE: (800) 232-7721 EMPLOYEE OWNED OFFICE AT 9 & SYCAMORE FAX: (319) 232-0330 PROPOSAL DATE June 4, 2003 To: Roseland Mackey Harris Architects Re: Phi Gamma Delta Fraternity-Restrooms 2330 Lincoln Way Ames, IA Ames, 1A 50014 Automatic Sprinklers Att: Mr. Kurt J. Mackey BLACKHAWK AUTOMATIC SPRINKLERS, INC. (SELLER) PROPOSES TO PROVIDE &/OR INSTALL: EQUIPMENT QUANTITY SIZE & DESCRIPTION SPRINKLERS 8 '/2" Concealed residential pendent. (Pipe to be concealed above ceiling) SYSTEM Per NFPA 13R—Residential Sprinkler Systems. (Attic, porches, combustible blind DESIGN spaces and small closets and restrooms not required to be sprinklered). ALARM None To be provided for in future phase. ACTUATING DEVICE ALARM None To be provided for in future phase. CONTROL None To be provided for in future phase. VALVES WATER None To be provided for in future phase. SUPPLY FIRE DEPT. CONN. None To be provided for in future phase. STANDARD ITEMS None Reserve Head Cabinet, Wrench, Inspectors Test, & Main Drain Piped Outside. SPECIALS APPROVAL BY: Local. EXCLUSIONS: Painting, Wiring, Supervisory Alarms, Special Markers, Installation Through or Above Suspended Ceilings, Special Environmental Requirements, Cutting/Patching Sheet Rock Walls/Ceilings, or any Overtime. NET Price One Thousand Eight Hundred Eighteen Dollars-------------------------------------------------($1,818.00) Includes Applicable Taxes, Freight&Transportation of Men to Site. Subject to General Terms & Conditions Alternate No. N.A. Alternate No. N.A. Alternate No. N.A. Alternate No. N.A. We Acknowledge Addendum No. By Anthony J. Holkan BLACKHAWK AUTOMATIC SPRINKLERS, INC. FIRE PROTECTION CONTRACTORS 0 DESIGN, INSTALLATION & MAINTENANCE P.O. BOX 1887 WATERLOO, IA 50704 TELEPHONE: (800) 232-7721 EMPLOYEE OWNED OFFICE AT 9 & SYCAMORE FAX: (319)232-0330 PROPOSAL DATE June 4, 2003 To: Roseland Mackey Harris Architects Re: Phi Gamma Delta Fraternity 2330 Lincoln Way Ames, IA Ames, IA 50014 Automatic Sprinklers Att: Mr. Kurt J. Mackey BLACKHAWK AUTOMATIC SPRINKLERS, INC. (SELLER) PROPOSES TO PROVIDE &/OR INSTALL: EQUIPMENT QUANTITY SIZE & DESCRIPTION SPRINKLERS 146 '/2"Chrome residential horizontal sidewall. (Piping exposed below ceilings) SYSTEM Per NFPA 13R—Residential Sprinkler Systems. (Attic, porches, combustible blind DESIGN spaces and small closets and restrooms not required to be sprinklered). ALARM 1 Flow switch. (No Wiring Included) ACTUATING DEVICE ALARM 1 Electric bell. (No Wiring Included) CONTROL 2 OS&Y vaave with tamper switch. (No Wiring Included) VALVES WATER None New 4"underground sprinkler main by others. SUPPLY Terminating above floor with standard 4 x 9 flange. FIRE DEPT. CONN. 1 Bronze with check valve. STANDARD ITEMS 1 Lot Reserve Head Cabinet, Wrench, Inspectors Test, & Main Drain Piped Outside. SPECIALS I Double check valve in main riser. APPROVAL BY: Local. EXCLUSIONS: Painting, Wiring, Supervisory Alarms, Special Markers, Installation Through or Above Suspended Ceilings, Special Environmental Requirements, Cutting/Patching Sheet Rock Walls/Ceilings, or any Overtime. NET Price Thirty-seven Thousand Four Hundred Eighty Dollars----------------------------------($37,480.00) Includes Applicable Taxes, Freight&Transportation of Men to Site. Subject to General Terms & Conditions Alternate No. N.A. Alternate No. N.A. Alternate No. N.A. Alternate No. N.A. We Acknowledge Addendum No. By Anthony J. Holkan