HomeMy WebLinkAboutA001 - Recommendation from Building Code Board of Apeals dated September 8, 1994 TO Mayor and City Council FROM: Building Code Board of Appeals DATE: September 8, 1994 SUBJECT: Foundations On March 12, 1993, the Interim Building, Electrical and Plumbing Boards presented to the Council their proposed revisions and changes to the local codes. At that time, the Building Code Board of Appeals recommended deletion of Section 5.119 Foundation Walls (see attached). This change was approved by the Council. Since then, the Board has met many times to discuss the design of foundations, primarily concrete, with members of the Ames Home Builders Association, concrete contractors, and other concerned individuals. Most of the discussion centered on the amount of steel reinforcing required in concrete foundation walls by the Uniform Building Code. Alternative designs with lower reinforcing requirements were presented to the Board, but these were presented as economic alternatives and were not backed up by engineering calculations. As a result of these discussions, it is the recommendation of the Building Code Board of Appeals that the foundation requirements of the 1991 Uniform Building Code be enforced. In addition, the Board recommends that a foundation inspection requirement should be incorporated into the language of the local code to ensure compliance. Respectfully submitted, K"Mackey, airman Building Code Board of Appeals Sec. 5.108(3) (a) Changed from "after trenches are excavated and forms erected" to "after excavations are complete and forms. . ." Sec. 5.108(6)(a) Changed from "may" to "shall" and deleted the words "at all times." We also referred back to the list of special inspections in the 1991 UBC Sec. 306(a)1-14. This was changed because the UBC had major revisions in this area and we felt the UBC was a fair but safe ruling in this matter. Sec. 5.115 Handicap Requirements was deleted because this was added to the 1991 UBC during its revision. Sec. 5.116 Parapets was deleted, in 1991 UBC. Sec. 5.119 This section on foundation walls was deleted. The 1991 UBC had some additions which help with interpretation. The Board chooses to review this and make recommendations at a later time. Sec. 5.121 Added: "Pole buildings shall be set in concrete mixed prior to filling cavity and must have horizontal rod tied to or drilled through each pole." This was added to tie the building to subgrade and help in case of uplift. The Board may continue to review this at a later time. Trench footings are allowed as a continuous 8" single pass trench for a single story wood frame structure with spans not exceeding 161. The trench must be 42" deep and have at least two (2) horizontal rods fixed in place and tied into the existing structure. Soil bearing pressure to be minimum of 2000 psi. Deleted Figure 2907(a) The Board found many inconsistencies with the wall sections and removed them. This area will be studied further. Sec. 5.122 Deleted - Handicap requirements was added in 1991 UBC. Sec. 5.123 Deleted - Handicap accessibility was added in 1991 UBC.